Effect of Prenatal Ultrasound Screening on Perinatal Outcome
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Many clinicians advocate routine ultrasound screening during pregnancy to detect congenital anomalies, multiple-gestation pregnancies, fetal growth disorders, placental abnormalities, and errors in the estimation of gestational age. However, it is not known whether the detection of these conditions through screening leads to interventions that improve perinatal outcome. METHODS: We conducted a randomized trial involving 15,151 pregnant women at low risk for perinatal problems to determine whether ultrasound screening decreased the frequency of adverse perinatal outcomes. The women randomly assigned to the ultrasound-screening group underwent one sonographic examination at 15 to 22 weeks of gestation and another at 31 to 35 weeks. The women in the control group underwent ultrasonography only for medical indications, as identified by their physicians. Adverse perinatal outcome was defined as fetal death, neonatal death, or neonatal morbidity such as intraventricular hemorrhage. RESULTS: The mean numbers of sonograms obtained per woman in the ultrasound-screening and control groups were 2.2 and 0.6, respectively. The rate of adverse perinatal outcome was 5.0 percent among the infants of the women in the ultrasound-screening group and 4.9 percent among the infants of the women in the control group (relative risk, 1.0; 95 percent confidence interval, 0.9 to 1.2; P = 0.85). The rates of preterm delivery and the distribution of birth weights were nearly identical in the two groups. The ultrasonographic detection of congenital anomalies had no effect on perinatal outcome. There were no significant differences between the groups in perinatal outcome in the subgroups of women with post-date pregnancies, multiple-gestation pregnancies, or infants who were small for gestational age. CONCLUSIONS: Screening ultrasonography did not improve perinatal outcome as compared with the selective use of ultrasonography on the basis of clinician judgment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Statistical Methods
(1999) · Technometrics · doi:10.1080/00401706.1999.10485954 · Cited by 6,090
A standard of fetal growth for the united states of America
Brenner, W. E., Edelman, D. A., & Hendricks, C. H. (1976) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(76)90748-1 · Cited by 836
Saari-Kemppainen, A., Karjalainen, O., Ylostalo, P., & Heinonen, O. P. (1990) · The Lancet · doi:10.1016/0140-6736(90)91941-3 · Cited by 359
Properties of the urn randomization in clinical trials
Wei, L. J., & Lachin, J. M. (1988) · Controlled Clinical Trials · doi:10.1016/0197-2456(88)90048-7 · Cited by 308
Chitty, L. S., Hunt, G. H., Moore, J., & Lobb, M. O. (1991) · BMJ · doi:10.1136/bmj.303.6811.1165 · Cited by 292
EFFECTS OF ROUTINE ONE-STAGE ULTRASOUND SCREENING IN PREGNANCY: A RANDOMISED CONTROLLED TRIAL
Waldenström, U., Nilsson, S., Fall, O., Axelsson, O., Eklund, G., Lindeberg, S., & Sjödin, Y. (1988) · The Lancet · doi:10.1016/s0140-6736(88)90636-8 · Cited by 194
RANDOMISED CONTROLLED TRIAL OF ULTRASONOGRAPHIC SCREENING IN PREGNANCY
Bakketeig, L., Jacobsen, G., Brodtkorb, C., Eriksen, B., Eik-Nes, S., Ulstein, M., Balstad, P., & Jörgensen, N. (1984) · The Lancet · doi:10.1016/s0140-6736(84)90492-6 · Cited by 193
What Do Patients Value?: Willingness to Pay for Ultrasound in Normal Pregnancy
Berwick, D. M., & Weinstein, M. C. (1985) · Medical Care · doi:10.1097/00005650-198507000-00005 · Cited by 178
Screening for small for dates fetuses: a controlled trial.
Neilson, J. P., Munjanja, S. P., & Whitfield, C. R. (1984) · BMJ · doi:10.1136/bmj.289.6453.1179 · Cited by 133
Larsen, T., Larsen, J. F., Petersen, S., & Greisen, G. O. (1992) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1992.tb13783.x · Cited by 78
Routine hospital admission in twin pregnancy between 26 and 30 weeks' gestation
MACLENNAN, A. (1990) · The Lancet · doi:10.1016/0140-6736(90)90079-k · Cited by 72
A randomized trial of routine prenatal ultrasound.
Ewigman, B., LeFevre, M. L., & Hesser, J. W. (1990) · PubMed · Cited by 72
Self-citationAntepartum obstetrical ultrasound examination guidelines.
Leopold, G. R. (1986) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1986.5.5.241 · Cited by 51
Failure to prevent preterm labour and delivery in twin pregnancy using prophylactic oral salbutamol
ASHWORTH, M. F., SPOONER, S. F., VERKUYL, D. A. A., WATERMAN, R., & ASHURST, H. M. (1990) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1990.tb02441.x · Cited by 46
CROWTHER, C. A., VERKUYL, D. A. A., NEILSON, J. P., BANNERMAN, C., & ASHURST, H. M. (1990) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1990.tb02440.x · Cited by 42
Secher, N. J., Hansen, P. K., Lenstrup, C., et al. (1987) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1987.tb02334.x · Cited by 24
Sensitivity of routine ultrasonographic screening for congenital anomalies during the last 5 years
Levi, S., & Hyjazi, Y. (1992) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1992.11.5.188 · Cited by 14
Consensus Conference: The use of diagnostic ultrasound imaging during pregnancy
(1984) · JAMA · doi:10.1001/jama.252.5.669 · Cited by 14
Cited by
Practice Bulletin No. 183: postpartum hemorrhage
(2017) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002351 · Cited by 1,406
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
Interventions for promoting smoking cessation during pregnancy
Lumley, J., Chamberlain, C., Dowswell, T., Oliver, S., Oakley, L., & Watson, L. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001055.pub3 · Cited by 890
Psychosocial interventions for supporting women to stop smoking in pregnancy
Chamberlain, C., O'Mara-Eves, A., Porter, J., Coleman, T., Perlen, S. M., Thomas, J., & McKenzie, J. E. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001055.pub5 · Cited by 650
Interventions for promoting smoking cessation during pregnancy
Lumley, J., Oliver, S., Chamberlain, C., & Oakley, L. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001055.pub2 · Cited by 622
Metadata
- Authors
- Ewigman, B. G., Crane, J. P., Frigoletto, F. D., LeFevre, M. L., Bain, R. P., & McNellis, D.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1993-09-16
- Volume
- 329
- Issue
- 12
- Pages
- 821-827
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2314666687
- Cited by
- 600
- References
- 18
- FWCI
- 33.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.