A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery Disease
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Coronary-stent placement is a new technique in which a balloon-expandable, stainless-steel, slotted tube is implanted at the site of a coronary stenosis. The purpose of this study was to compare the effects of stent placement and standard balloon angioplasty on angiographically detected restenosis and clinical outcomes. METHODS: We randomly assigned 410 patients with symptomatic coronary disease to elective placement of a Palmaz-Schatz stent or to standard balloon angioplasty. Coronary angiography was performed at base line, immediately after the procedure, and six months later. RESULTS: The patients who underwent stenting had a higher rate of procedural success than those who underwent standard balloon angioplasty (96.1 percent vs. 89.6 percent, P = 0.011), a larger immediate increase in the diameter of the lumen (1.72 +/- 0.46 vs. 1.23 +/- 0.48 mm, P < 0.001), and a larger luminal diameter immediately after the procedure (2.49 +/- 0.43 vs. 1.99 +/- 0.47 mm, P < 0.001). At six months, the patients with stented lesions continued to have a larger luminal diameter (1.74 +/- 0.60 vs. 1.56 +/- 0.65 mm, P = 0.007) and a lower rate of restenosis (31.6 percent vs. 42.1 percent, P = 0.046) than those treated with balloon angioplasty. There were no coronary events (death; myocardial infarction; coronary-artery bypass surgery; vessel closure, including stent thrombosis; or repeated angioplasty) in 80.5 percent of the patients in the stent group and 76.2 percent of those in the angioplasty group (P = 0.16). Revascularization of the original target lesion because of recurrent myocardial ischemia was performed less frequently in the stent group than in the angioplasty group (10.2 percent vs. 15.4 percent, P = 0.06). CONCLUSIONS: In selected patients, placement of an intracoronary stent, as compared with balloon angioplasty, results in an improved rate of procedural success, a lower rate of angiographically detected restenosis, a similar rate of clinical events after six months, and a less frequent need for revascularization of the original coronary lesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Statistical Analysis of Failure Time Data.
Aitkin, M., Kalbfleisch, J. D., & Prentice, R. L. (1981) · Biometrics · doi:10.2307/2530581 · Cited by 9,877
Holmes, D. R., Vlietstra, R. E., Smith, H. C., Vetrovec, G. W., Kent, K. M., Cowley, M. J., Faxon, D. P., Gruentzig, A. R., Kelsey, S. F., Detre, K. M., et al. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90752-5 · Cited by 1,113
Self-citationNobuyoshi, M., Kimura, T., Nosaka, H., Mioka, S., Ueno, K., Yokoi, H., Hamasaki, N., Horiuchi, H., & Ohishi, H. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(88)80046-9 · Cited by 875
Self-citationTopol, E. J., Leya, F., Pinkerton, C. A., Whitlow, P. L., Hofling, B., Simonton, C. A., Masden, R. R., Serruys, P. W., Leon, M. B., Williams, D. O., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307223290401 · Cited by 698
Self-citationSchwartz, L., Bourassa, M. G., Lespérance, J., Aldridge, H. E., Kazim, F., Salvatori, V. A., Henderson, M., Bonan, R., & David, P. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806303182603 · Cited by 692
Hirshfeld, J. W., Schwartz, J. S., Jugo, R., Macdonald, R. G., Goldberg, S., Savage, M. P., Bass, T. A., Vetrovec, G., Cowley, M., Taussig, A. S., et al. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90783-6 · Cited by 391
Self-citationDehmer, G. J., Popma, J. J., van den Berg, E. K., Eichhorn, E. J., Prewitt, J. B., Campbell, W. B., Jennings, L., Willerson, J. T., & Schmitz, J. M. (1988) · New England Journal of Medicine · doi:10.1056/nejm198809223191201 · Cited by 379
Thornton, M. A., Gruentzig, A. R., Hollman, J., King, S. B., & Douglas, J. S. (1984) · Circulation · doi:10.1161/01.cir.69.4.721 · Cited by 358
Waller, B. F. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90248-9 · Cited by 318
Adelman, A. G., Cohen, E. A., Kimball, B. P., Bonan, R., Ricci, D. R., Webb, J. G., Laramée, L., Barbeau, G. R., Traboulsi, M., Corbett, B. N., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307223290402 · Cited by 308
Self-citationPepine, C. J., Hirshfeld, J. W., Macdonald, R. G., Henderson, M. A., Bass, T. A., Goldberg, S., Savage, M. P., Vetrovec, G., Cowley, M., & Taussig, A. S. (1990) · Circulation · doi:10.1161/01.cir.81.6.1753 · Cited by 247
Self-citationFailure of diltiazem to prevent restenosis after percutaneous transluminal coronary angioplasty
Corcos, T., David, P. R., Val, P. G., Renkin, J., Dangoisse, V., Rapold, H. G., & Bourassa, M. G. (1985) · American Heart Journal · doi:10.1016/0002-8703(85)90231-5 · Cited by 234
RANDOMISED TRIAL OF FISH OIL FOR PREVENTION OF RESTENOSIS AFTER CORONARY ANGIOPLASTY
Reis, G., Sipperly, M., Mccabe, C., Sacks, F., Boucher, T., Silverman, D., Baim, D., Grossman, W., & Pasternak, R. (1989) · The Lancet · doi:10.1016/s0140-6736(89)90370-x · Cited by 218
Self-citation
Cited by
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Self-citationMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationWriting Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
Self-citationA Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Self-citationWRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Self-citation
Metadata
- Authors
- Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., Cleman, M., Heuser, R., Almond, D., Teirstein, P. S., Fish, R. D., Colombo, A., Brinker, J., Moses, J., Shaknovich, A., Hirshfeld, J., Bailey, S., Ellis, S., Rake, R., & Goldberg, S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1994-08-25
- Volume
- 331
- Issue
- 8
- Pages
- 496-501
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2324489407
- Cited by
- 4,271
- References
- 13
- FWCI
- 238.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.