Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Treatment of stenosis in saphenous-vein grafts after coronary-artery bypass surgery is a difficult challenge. The purpose of this study was to compare the effects of stent placement with those of balloon angioplasty on clinical and angiographic outcomes in patients with obstructive disease of saphenous-vein grafts. METHODS: A total of 220 patients with new lesions in aortocoronary-venous bypass grafts were randomly assigned to placement of Palmaz-Schatz stents or standard balloon angioplasty. Coronary angiography was performed during the index procedure and six months later. RESULTS: As compared with the patients assigned to angioplasty, those assigned to stenting had a higher rate of procedural efficacy, defined as a reduction in stenosis to less than 50 percent of the vessel diameter without a major cardiac complication (92 percent vs. 69 percent, P<0.001), but they had more frequent hemorrhagic complications (17 percent vs. 5 percent, P<0.01). Patients in the stent group had a larger mean (+/-SD) increase in luminal diameter immediately after the procedure (1.92+/-0.30 mm, as compared with 1.21+/-0.37 mm in the angioplasty group; P<0.001) and a greater mean net gain in luminal diameter at six months (0.85+/-0.96 vs. 0.54+/-0.91 mm, P=0.002). Restenosis occurred in 37 percent of the patients in the stent group and in 46 percent of the patients in the angioplasty group (P=0.24). The outcome in terms of freedom from death, myocardial infarction, repeated bypass surgery, or revascularization of the target lesion was significantly better in the stent group (73 percent vs. 58 percent, P = 0.03). CONCLUSIONS: As compared with balloon angioplasty, stenting of selected venous bypass-graft lesions resulted in superior procedural outcomes, a larger gain in luminal diameter, and a reduction in major cardiac events. However, there was no significant benefit in the rate of angiographic restenosis, which was the primary end point of the study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citationSchömig, A., Neumann, F.-J., Kastrati, A., Schühlen, H., Blasini, R., Hadamitzky, M., Walter, H., Zitzmann-Roth, E.-M., Richardt, G., Alt, E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341702 · Cited by 2,028
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1676 · Cited by 1,428
Self-citationLytle, B. W., Loop, F. D., Cosgrove, D. M., Ratliff, N. B., Easley, K., & Taylor, P. C. (1985) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)38820-8 · Cited by 939
Coronary bypass graft fate: Long-term angiographic study
FitzGibbon, G. M., Leach, A. J., Kafka, H. P., & Keon, W. J. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90834-v · Cited by 233
Progression of atherosclerosis in coronary arteries and bypass grafts: Ten years later
Bourassa, M. G., Enjalbert, M., Campeau, L., & Lesperance, J. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90759-8 · Cited by 202
Holmes, D. R., Topol, E. J., Califf, R. M., Berdan, L. G., Leya, F., Berger, P. B., Whitlow, P. L., Safian, R. D., Adelman, A. G., Kellett, M. A., et al. (1995) · Circulation · doi:10.1161/01.cir.91.7.1966 · Cited by 201
Self-citationLawrie, G. M., Lie, J. T., Morris, G. C., & Beazley, H. L. (1976) · The American Journal of Cardiology · doi:10.1016/0002-9149(76)90798-0 · Cited by 192
Hamby, R. I., Aintablian, A., Handler, M., Voleti, C. D., Weisz, D., Garvey, J. W., & Wisoff, G. (1979) · Circulation · doi:10.1161/01.cir.60.4.901 · Cited by 94
Cited by
What is meant by intention to treat analysis? Survey of published randomised controlled trials
Hollis, S., & Campbell, F. (1999) · BMJ · doi:10.1136/bmj.319.7211.670 · Cited by 2,160
ACC/AHA guidelines for coronary artery bypass graft surgery
Eagle, K. A., Guyton, R. A., Davidoff, R., Ewy, G. A., Fonger, J., Gardner, T. J., Gott, J. P., Herrmann, H. C., Marlow, R. A., Nugent, W. C., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00389-7 · Cited by 1,995
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.181940 · Cited by 1,853
Guidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.013 · Cited by 1,510
Scanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123
Self-citationBraunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00889-5 · Cited by 963
Self-citationAnderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.014 · Cited by 960
Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Stent Thrombosis in the Modern Era: A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Cutlip, D. E., Baim, D. S., Ho, K. K. L., Popma, J. J., Lansky, A. J., Cohen, D. J., Carrozza, J. P., Chauhan, M. S., Rodriguez, O., & Kuntz, R. E. (2001) · Circulation · doi:10.1161/01.cir.103.15.1967 · Cited by 855
Serruys, P. W., Kutryk, M. J. B., & Ong, A. T. L. (2006) · New England Journal of Medicine · doi:10.1056/nejmra051091 · Cited by 762
Gibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
Self-citationACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
Self-citationWright, R. S., Anderson, J. L., Adams, C. D., Bridges, C. R., Casey, D. E., Ettinger, S. M., Fesmire, F. M., Ganiats, T. G., Jneid, H., Lincoff, A. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.02.011 · Cited by 516
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.007 · Cited by 501
ACC/AHA/SCAI Practice Guidelines, February 21, 2006
(2006) · Circulation · doi:10.1161/circulationaha.106.173220 · Cited by 422
Harskamp, R. E., Lopes, R. D., Baisden, C. E., de Winter, R. J., & Alexander, J. H. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e318288c38d · Cited by 370
Meta-analysis of randomized and registry comparisons of ticlopidine with clopidogrel after stenting
Bhatt, D. L., Bertrand, M. E., Berger, P. B., L’Allier, P. L., Moussa, I., Moses, J. W., Dangas, G., Taniuchi, M., Lasala, J. M., Holmes, D. R., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01713-2 · Cited by 362
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318212bb8b · Cited by 343
Vein graft failure: from pathophysiology to clinical outcomes
de Vries, M. R., Simons, K. H., Jukema, J. W., Braun, J., & Quax, P. H. A. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.76 · Cited by 301
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.028 · Cited by 283
2007 WRITING COMMITTEE MEMBERS, Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828478ac · Cited by 272
Vermeersch, P., Agostoni, P., Verheye, S., Van den Heuvel, P., Convens, C., Bruining, N., Van den Branden, F., & Van Langenhove, G. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.09.021 · Cited by 256
Saphenous Vein Graft Failure: From Pathophysiology to Prevention and Treatment Strategies
Xenogiannis, I., Zenati, M., Bhatt, D. L., Rao, S. V., Rodés-Cabau, J., Goldman, S., Shunk, K. A., Mavromatis, K., Banerjee, S., Alaswad, K., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.052163 · Cited by 211
Evidence for Use of Coronary Stents: A Hierarchical Bayesian Meta-Analysis
Brophy, J. M., Belisle, P., & Joseph, L. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-10-200305200-00005 · Cited by 207
Morrison, D. A., Sethi, G., Sacks, J., Henderson, W. G., Grover, F., Sedlis, S., & Esposito, R. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02560-3 · Cited by 195
Mehilli, J., Pache, J., Abdel-Wahab, M., Schulz, S., Byrne, R. A., Tiroch, K., Hausleiter, J., Seyfarth, M., Ott, I., Ibrahim, T., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61255-5 · Cited by 187
Stankovic, G., Colombo, A., Presbitero, P., van den Branden, F., Inglese, L., Cernigliaro, C., Niccoli, L., Bartorelli, A. L., Rubartelli, P., Reifart, N., et al. (2003) · Circulation · doi:10.1161/01.cir.0000079106.71097.1c · Cited by 184
Keeley, E. C., Velez, C. A., O’Neill, W. W., & Safian, R. D. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01420-6 · Cited by 170
Self-citationClopidogrel: A Review of its Use in the Prevention of Atherothrombosis
Jarvis, B., & Simpson, K. (2000) · Drugs · doi:10.2165/00003495-200060020-00012 · Cited by 168
Metadata
- Authors
- Savage, M. P., Douglas, J. S., Fischman, D. L., Pepine, C. J., King, S. B., Werner, J. A., Bailey, S. R., Overlie, P. A., Fenton, S. H., Brinker, J. A., Leon, M. B., Goldberg, S., Heuser, R., Smalling, R., Safian, R. D., Cleman, M., Buchbinder, M., Snead, D., Rake, R. C., & Gebhardt, S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1997-09-11
- Volume
- 337
- Issue
- 11
- Pages
- 740-747
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2329072970
- Cited by
- 486
- References
- 10
- FWCI
- 44.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.