The DOI matches its Crossref record.
Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance
Open accessAbstract
Background The placement of stents in coronary arteries has been shown to reduce restenosis in comparison to balloon angioplasty. However, clinical use of intracoronary stents is impeded by the risk of subacute stent thrombosis and complications associated with the anticoagulant regimen. To reduce these complications, the hypothesis that systemic anticoagulation is not necessary when adequate stent expansion is achieved was prospectively evaluated on a consecutive series of patients who received intracoronary stents. Methods and Results From March 1993 to January 1994, 359 patients underwent Palmaz-Schatz coronary stent insertion. After an initial successful angiographic result with <20% stenosis by visual estimation had been achieved, intravascular ultrasound imaging was performed. Further balloon dilatation of the stent was guided by observation of the intravascular ultrasound images. All patients with adequate stent expansion confirmed by ultrasound were treated only with antiplatelet therapy (either ticlopidine for 1 month with short-term aspirin for 5 days or only aspirin) after the procedure. Clinical success (procedure success without early postprocedural events) at 2 months was achieved in 338 patients (94%). With an inflation pressure of 14.9±3.0 atm and a balloon-to-vessel ratio of 1.17±0.19, optimal stent expansion was achieved in 321 of the 334 patients (96%) who underwent intravascular ultrasound evaluation, with these patients receiving only antiplatelet therapy after the procedure. Despite the absence of anticoagulation, there were only two acute stent thromboses (0.6%) and one subacute stent thrombosis (0.3%) at 2-month clinical follow-up. Follow-up angiography at 3 to 6 months documented two additional occlusions (0.6%) at the stent site. At 6-month clinical follow-up, angiographically documented stent occlusion had occurred in 5 patients (1.6%). At 6-month clinical follow-up, there was a 5.7% incidence of myocardial infarction, a 6.4% rate of coronary bypass surgery, and a 1.9% incidence of death. Emergency intervention (emergency angioplasty or bailout stent) for a stent thrombosis event was performed in 3 patients (0.8%). The overall event rate was relatively high because of intraprocedural complications that occurred in 16 patients (4.5%). Intraprocedural complications, however, decreased to 1% when angiographically appropriately sized balloons were used for final stent dilations. There was one ischemic vascular complication that occurred at the time of the procedure and one ischemic vascular complication that occurred at the time of angiographic follow-up. By 6 months, repeat angioplasty for symptomatic restenosis was performed in 47 patients (13.1%). Conclusions The Palmaz-Schatz stent can be safely inserted in coronary arteries without subsequent anticoagulation provided that stent expansion is adequate and there are no other flow-limiting lesions present. The use of high-pressure final balloon dilatations and confirmation of adequate stent expansion by intravascular ultrasound provide assurance that anticoagulation therapy can be safely omitted. This technique significantly reduces hospital time and vascular complications and has a low stent thrombosis rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Scanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123
Stent Thrombosis in the Modern Era: A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Cutlip, D. E., Baim, D. S., Ho, K. K. L., Popma, J. J., Lansky, A. J., Cohen, D. J., Carrozza, J. P., Chauhan, M. S., Rodriguez, O., & Kuntz, R. E. (2001) · Circulation · doi:10.1161/01.cir.103.15.1967 · Cited by 855
Lau, W. C., Waskell, L. A., Watkins, P. B., Neer, C. J., Horowitz, K., Hopp, A. S., Tait, A. R., Carville, D. G. M., Guyer, K. E., & Bates, E. R. (2003) · Circulation · doi:10.1161/01.cir.0000047060.60595.cc · Cited by 688
Smith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
Savage, M. P., Douglas, J. S., Fischman, D. L., Pepine, C. J., King, S. B., Werner, J. A., Bailey, S. R., Overlie, P. A., Fenton, S. H., Brinker, J. A., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709113371103 · Cited by 486
Self-citation
Metadata
- Authors
- Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M.
- Venue
- Circulation
- Published
- 1995-03-15
- Volume
- 91
- Issue
- 6
- Pages
- 1676-1688
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2112020699
- Cited by
- 1,428
- References
- 0
- FWCI
- 191.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance. https://app.cochat.ai/papers/10.1161/01.cir.91.6.1676
- The paper
- Colombo, A., Hall, P., Nakamura, S., Almagor, Y., Maiello, L., Martini, G., Gaglione, A., Goldberg, S. L., & Tobis, J. M. (1995). Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound Guidance. Circulation. https://doi.org/10.1161/01.cir.91.6.1676
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.