Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 3,232

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A Comparison of Antiarrhythmic-Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near-Fatal Ventricular Arrhythmias

Open access
·1997·New England Journal of Medicine

Abstract

BACKGROUND: Patients who survive life-threatening ventricular arrhythmias are at risk for recurrent arrhythmias. They can be treated with either an implantable cardioverter-defibrillator or antiarrhythmic drugs, but the relative efficacy of these two treatment strategies is unknown. METHODS: To address this issue, we conducted a randomized comparison of these two treatment strategies in patients who had been resuscitated from near-fatal ventricular fibrillation or who had undergone cardioversion from sustained ventricular tachycardia. Patients with ventricular tachycardia also had either syncope or other serious cardiac symptoms, along with a left ventricular ejection fraction of 0.40 or less. One group of patients was treated with implantation of a cardioverter-defibrillator; the other received class III antiarrhythmic drugs, primarily amiodarone at empirically determined doses. Fifty-six clinical centers screened all patients who presented with ventricular tachycardia or ventricular fibrillation during a period of nearly four years. Of 1016 patients (45 percent of whom had ventricular fibrillation, and 55 percent ventricular tachycardia), 507 were randomly assigned to treatment with implantable cardioverter-defibrillators and 509 to antiarrhythmic-drug therapy. The primary end point was overall mortality. RESULTS: Follow-up was complete for 1013 patients (99.7 percent). Overall survival was greater with the implantable defibrillator, with unadjusted estimates of 89.3 percent, as compared with 82.3 percent in the antiarrhythmic-drug group at one year, 81.6 percent versus 74.7 percent at two years, and 75.4 percent versus 64.1 percent at three years (P<0.02). The corresponding reductions in mortality (with 95 percent confidence limits) with the implantable defibrillator were 39+/-20 percent, 27+/-21 percent, and 31+/-21 percent CONCLUSIONS: Among survivors of ventricular fibrillation or sustained ventricular tachycardia causing severe symptoms, the implantable cardioverter-defibrillator is superior to antiarrhythmic drugs for increasing overall survival.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199711273372202

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 3,232

Metadata

Venue
New England Journal of Medicine
Published
1997-11-27
Volume
337
Issue
22
Pages
1576-1584
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2269745365
Cited by
3,232
References
2
FWCI
84.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Antiarrhythmic-Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near-Fatal Ventricular Arrhythmias. https://app.cochat.ai/papers/10.1056/nejm199711273372202
The paper
A Comparison of Antiarrhythmic-Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near-Fatal Ventricular Arrhythmias. (1997). New England Journal of Medicine. https://doi.org/10.1056/nejm199711273372202

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.