Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,109

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Liver Failure and Death after Exposure to Microcystins at a Hemodialysis Center in Brazil

Open access
Jochimsen, Elise M., Carmichael, Wayne W., An, JiSi, Cardo, Denise M., Cookson, Susan T., Holmes, Christianne E.M., Antunes, M. Bernade, de Melo Filho, Djalma A., Lyra, Tereza M., Barreto, Victorino Spinelli T., Azevedo, Sandra M.F.O., Jarvis, William R.·1998·New England Journal of Medicine

Abstract

BACKGROUND: Hemodialysis is a common but potentially hazardous procedure. From February 17 to 20, 1996, 116 of 130 patients (89 percent) at a dialysis center (dialysis center A) in Caruaru, Brazil, had visual disturbances, nausea, and vomiting associated with hemodialysis. By March 24, 26 of the patients had died of acute liver failure. METHODS: A case patient was defined as any patient undergoing dialysis at dialysis center A or Caruaru's other dialysis center (dialysis center B) during February 1996 who had acute liver failure. To determine the risk factors for and the source of the outbreak, we conducted a cohort study of the 130 patients at dialysis center A and the 47 patients at dialysis center B, reviewed the centers' water supplies, and collected water, patients' serum, and postmortem liver tissue for microcystin assays. RESULTS: One hundred one patients (all at dialysis center A) met the case definition, and 50 died. Affected patients who died were older than those who survived (median age, 47 vs. 35 years, P<0.001). Furthermore, all 17 patients undergoing dialysis on the Tuesday-, Thursday-, and Saturday-night schedule became ill, and 13 of them (76 percent) died. Both centers received water from a nearby reservoir. However, the water supplied to dialysis center B was treated, filtered, and chlorinated, whereas the water supplied to dialysis center A was not. Microcystins produced by cyanobacteria were detected in water from the reservoir and from dialysis center A and in serum and liver tissue of case patients. CONCLUSIONS: Water used for hemodialysis can contain toxic materials, and its quality should therefore be carefully monitored.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm199803263381304

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 1,109

Metadata

Authors
Jochimsen, E. M., Carmichael, W. W., An, J., Cardo, D. M., Cookson, S. T., Holmes, C. E. M., Antunes, M. B., de Melo Filho, D. A., Lyra, T. M., Barreto, V. S. T., Azevedo, S. M. F. O., & Jarvis, W. R.
Venue
New England Journal of Medicine
Published
1998-03-26
Volume
338
Issue
13
Pages
873-878
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W1990031184
Cited by
1,109
References
1
FWCI
52.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liver Failure and Death after Exposure to Microcystins at a Hemodialysis Center in Brazil. https://app.cochat.ai/papers/10.1056/nejm199803263381304
The paper
Jochimsen, E. M., Carmichael, W. W., An, J., Cardo, D. M., Cookson, S. T., Holmes, C. E. M., Antunes, M. B., de Melo Filho, D. A., Lyra, T. M., Barreto, V. S. T., Azevedo, S. M. F. O., & Jarvis, W. R. (1998). Liver Failure and Death after Exposure to Microcystins at a Hemodialysis Center in Brazil. New England Journal of Medicine. https://doi.org/10.1056/nejm199803263381304