Clinical Consequences of Electrocardiographic Artifact Mimicking Ventricular Tachycardia
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Electrocardiographic artifact can simulate ventricular tachycardia. The literature regarding electrocardiographic artifact is limited to case reports,1–7 proposed classifications,8,9 and diagnostic criteria.10 There is little information regarding the clinical implications of the misdiagnosis of artifact as ventricular tachycardia. We describe 12 patients who underwent unnecessary diagnostic or therapeutic interventions as a result of such a misdiagnosis. Methods We included in this series patients who were seen in consultation by a cardiac electrophysiologist at our institution between 1995 and 1999 and who underwent a diagnostic procedure or received treatment unnecessarily, solely as a result of the misdiagnosis of artifact as . . .
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“False positives may lead to inappropriate medical interventions (Knight et al., 1999).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Knight et al., 1999
Citations
Cites
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
(1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00024-2 · Cited by 632
Efficacy of permanent pacing in the management of high-risk patients with long QT syndrome.
Moss, A. J., Liu, J. E., Gottlieb, S., Locati, E. H., Schwartz, P. J., & Robinson, J. L. (1991) · Circulation · doi:10.1161/01.cir.84.4.1524 · Cited by 194
Artifacts in portable electrocardiographic monitoring
Krasnow, A. Z., & Bloomfield, D. K. (1976) · American Heart Journal · doi:10.1016/s0002-8703(76)80220-7 · Cited by 81
ECG Artifact Produced by Crystalloid Administration through Blood/fluid Warming Sets
Paulsen, A. W., & PRITCHARD, D. G. (1988) · Anesthesiology · doi:10.1097/00000542-198811000-00043 · Cited by 23
Artifact Simulating Ventricular and Atrial Arrhythmia.
Lin, S.-L., Wang, S., Kong, C., & Chang, M.-S. (1991) · Japanese Heart Journal · doi:10.1536/ihj.32.847 · Cited by 21
Electrocardiographic artifact caused by extracorporeal roller pump
Klcinman, B., Shah, K., Belusko, R., & Blakeman, B. M. (1990) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02832157 · Cited by 15
ECG Artifact Simulating Supraventricular Tachycardia During Automated Percutaneous Lumbar Discectomy
Lampert, B. A., & Sundstrom, F. D. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198811000-00014 · Cited by 11
Atypical ventricular tachycardia or motion artifact?
Falk, R. H., & Knowlton, A. A. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)91124-6 · Cited by 8
Life-threatening ECG Artifact during Extracorporeal Shock Wave Lithotripsy
SCHILLER, E. C., Heerdt, P. M., & ROBERTS, J. (1988) · Anesthesiology · doi:10.1097/00000542-198803000-00043 · Cited by 6
Research works printed but not linked: 1
- Murdock DK, 1986, Heart Lung, 15, 150
Cited by
Items 201–221 of 221
PhD, C. W. (2011) · doi:10.1002/9781119979487.ch40
Wide-complex tachycardia in a patient with syncope
Lin, D. (2012) · Canadian Journal of Emergency Medicine · doi:10.2310/8000.2012.110443a
Domínguez-Pérez, L., Arias, M. A., & Padial, L. R. (2008) · Revista Clínica Española · doi:10.1016/s0014-2565(08)76039-9
Glancy, D. L., Rochon, B. J., Rodriguez, F. H., & Sandifer, A. A. (2007) · Baylor University Medical Center Proceedings · doi:10.1080/08998280.2007.11928282
(2007) · Springer eBooks · doi:10.1007/978-3-540-34372-1_27
All that quivers is not real: recognising pseudo-atrial flutter
Lai, Y., Chew, N., Sia, C., & Yeo, W. (2022) · Singapore Medical Journal · doi:10.11622/smedj.2022055
The First Whf Global Conference On Cardiovascular Clinical Trials
(2002) · Journal of the Hong Kong College of Cardiology · doi:10.55503/2790-6744.1181
Yue, C.-S., & Chan, W.-K. (2002) · Journal of the Hong Kong College of Cardiology · doi:10.55503/2790-6744.1187
CARDIOLOGIA EM FOCO: PREVENÇÃO, DIAGNÓSTICO E TRATAMENTOS ATUAIS
Almeida, A. B., & Horevicht, C. M. (2023) · EPITAYA eBooks · doi:10.47879/ed.ep.2023809
OS DIFERENTES TIPOS DE ARRITMIA CARDÍACA E SEUS MÉTODOS DE TRATAMENTO MAIS USUAIS
de Souza, R. V. O., Caldeira, R. M., Castello, R. C. R., & Lobo, T. F. D. C. (2023) · EPITAYA eBooks · doi:10.47879/ed.ep.2023809p57 · Cited by 3
Ramim, M. M., Patel, J., Pulickathadam, C., Shen, M., & Vinod, R. (2023) · Online Journal of Applied Knowledge Management · doi:10.36965/ojakm.2023.11(1)50-64
Improving Telemetry use in the Acute Assessment Unit
3, I. M. T., Timmons, P., Reid, L., Clare, K., Beckett, D. J., Thomson, T., & Fabisiak, L. (2024) · Acute Medicine Journal · doi:10.52964/amja.0969
Bartholomew, K. J. (2024) · Wiley eBooks · doi:10.1002/9781119830306.ch11
Torsades de Pointes in a Stable Patient With Parkinson Disease—Mimic or Life-Threatening Arrhythmia?
Manfrini, D., & Feldman, J. (2025) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2025.03.026
ECG Artifact Masquerading as Ventricular Tachycardia During Dofetilide Initiation
Weinstein, R. M., Brito, M., Custer, B., Kim, C. H., Marine, J. E., Berger, R. D., SPRAGG, D. D., & Kolandaivelu, A. (2026) · JACC Case Reports · doi:10.1016/j.jaccas.2026.107404
Broadening the Differential of Pseudo–Atrioventricular Block
Vernacchia, F., Sciarra, L., Gallina, S., Bagliani, G., & Ricci, F. (2026) · JACC Case Reports · doi:10.1016/j.jaccas.2026.108126
Aboulmaaty, M. (2026) · JACC Case Reports · doi:10.1016/j.jaccas.2026.108355
Tremor Artifact Presenting as Pseudo-Ventricular Tachycardia
Haiy, A. U., Basit, M. A., Mirza, H. M., Wasim, A., Jalil, A., & Bajwa, A. (2026) · JACC Case Reports · doi:10.1016/j.jaccas.2026.108029
Ji, Y., Liu, C., Li, P., Wang, C., Xie, H., Li, Y. I. F. E. I., & Ding, H. (2026) · BMC Cardiovascular Disorders · doi:10.1186/s12872-026-06105-z
“Such artifacts frequently obey the “single-limb lead exemption principle” [1, 2, 9], which is derived from the Einthoven triangle and Wilson Central Terminal (WCT) theory.”
Higueras, J., Olmos, C., Gómez-Polo, J. C., Playán-Escribano, J., de la Cruz, M. C., Areta, I. I., Redondo, I. R., & Vivas, D. (2026) · REC CardioClinics · doi:10.1016/j.rccl.2026.06.002
Casos clínicos: artefactos electrocardiográficos simulando arritmias ventriculares
Sánchez-Morago, S. G.-V., & Aguilar, B. Z. (2007) · Enfermería en cardiología: revista científica e informativa de la Asociación Española de Enfermería en Cardiología · Cited by 2
Metadata
- Authors
- Knight, B. P., Pelosi, F., Michaud, G. F., Strickberger, S. A., & Morady, F.
- Affiliations
- University of Michigan (US)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1999-10-21
- Volume
- 341
- Issue
- 17
- Pages
- 1270-1274
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2063378240
- Semantic Scholar
- ca4b68c9b86e4349c87b305c7537e2e0c8e70ab7
- Cited by
- 221
- References
- 13
- Citations by year
- 2026: 7 · 2025: 2 · 2024: 4 · 2023: 8 · 2022: 5 · 2021: 5 · 2020: 5 · 2019: 11 · 2018: 14 · 2017: 12 · 2016: 11 · 2015: 6 · 2014: 7 · 2013: 14 · 2012: 13
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- electrocardiogram artifacts, ventricular tachycardia, misdiagnosis, unnecessary diagnostic procedures, unnecessary treatment, cardiac electrophysiology
- MeSH terms
- Adult, Aged, Aged, 80 and over, Diagnosis, Differential, Diagnostic Errors, Electrocardiography, Female, Humans, Male, Middle Aged, Artifacts, Tachycardia, Ventricular, Unnecessary Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.