Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.

High Plasma Levels of Factor VIII and the Risk of Recurrent Venous Thromboembolism

Open access

Abstract

BACKGROUND: A high plasma level of factor VIII is a risk factor for venous thromboembolism. We evaluated the risk of a recurrence of thrombosis after an initial episode of spontaneous venous thromboembolism among patients with high plasma levels of factor VIII. METHODS: We studied 360 patients for an average follow-up period of 30 months after a first episode of venous thromboembolism and discontinuation of oral anticoagulants. Patients who had recurrent or secondary venous thromboembolism, a congenital deficiency of an anticoagulant, the lupus anticoagulant, hyperhomocysteinemia, cancer, or a requirement for long-term treatment with antithrombotic drugs or who were pregnant were excluded. The end point was objectively documented, symptomatic recurrent venous thromboembolism. RESULTS: Recurrent venous thromboembolism developed in 38 of the 360 patients (10.6 percent). Patients with recurrence had higher mean (+/-SD) plasma levels of factor VIII than those without recurrence (182+/-66 vs. 157+/-54 IU per deciliter, P=0.009). The relative risk of recurrent venous thrombosis was 1.08 (95 percent confidence interval, 1.04 to 1.12; P<0.001) for each increase of 10 IU per deciliter in the plasma level of factor VIII. Among patients with a factor VIII level above the 90th percentile of the values in the study population, the likelihood of recurrence at two years was 37 percent, as compared with a 5 percent likelihood among patients with lower levels (P<0.001). Among patients with plasma factor VIII levels above the 90th percentile, as compared with those with lower levels, the overall relative risk of recurrence was 6.7 (95 percent confidence interval, 3.0 to 14.8) after adjustment for age, sex, the presence or absence of factor V Leiden or the G20210A prothrombin mutation, and the duration of oral anticoagulation. CONCLUSIONS: Patients with a high plasma level of factor VIII have an increased risk of recurrent venous thromboembolism.

Overview

Integrity signals

Registry

Crossref · 10.1056/nejm200008173430702

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Research works printed but not linked: 2

  1. 10.2307/2281868 · doi:10.2307/2281868 · Paper page
  2. Eichinger S, 1998, Thromb Haemost, 80, 566

Cited by

See all 763

Metadata

Authors
Kyrle, P. A., Minar, E., Hirschl, M., Bialonczyk, C., Stain, M., Schneider, B., Weltermann, A., Speiser, W., Lechner, K., & Eichinger, S.
Affiliations
  • Medical University of Vienna (AT)
  • Hanusch Hospital (AT)
  • Wilhelminen Hospital (AT)
Venue
New England Journal of Medicine
Published
2000-08-17
Volume
343
Issue
7
Pages
457-462
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2337281790
Cited by
763
References
34
Citations by year
2026: 10 · 2025: 19 · 2024: 17 · 2023: 20 · 2022: 19 · 2021: 23 · 2020: 28 · 2019: 19 · 2018: 18 · 2017: 20 · 2016: 20 · 2015: 27 · 2014: 28 · 2013: 32 · 2012: 36
FWCI
26.89
Type
journal article
Language
en
Open access
Locations
  • New England Journal of Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Internal Medicine › Venous Thromboembolism Diagnosis and Management
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Hematology › Hemophilia Treatment and Research
Keywords
factor VIII, venous thromboembolism, recurrent thrombosis, hypercoagulability, thrombosis risk factors, factor V Leiden, prothrombin G20210A, oral anticoagulation
MeSH terms
Factor VIII, Female, Humans, Male, Middle Aged, Prospective Studies, Pulmonary Embolism, Recurrence, Risk, Risk Factors, Venous Thrombosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Plasma Levels of Factor VIII and the Risk of Recurrent Venous Thromboembolism. https://app.cochat.ai/papers/10.1056/nejm200008173430702
The paper
Kyrle, P. A., Minar, E., Hirschl, M., Bialonczyk, C., Stain, M., Schneider, B., Weltermann, A., Speiser, W., Lechner, K., & Eichinger, S. (2000). High Plasma Levels of Factor VIII and the Risk of Recurrent Venous Thromboembolism. New England Journal of Medicine. https://doi.org/10.1056/nejm200008173430702

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.