Continuous Glucose Monitoring — Coming of Age
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Advances in glucose-monitoring technology have been an important driver for improvements in the treatment of type 1 diabetes. The introduction of fingerstick capillary blood glucose monitoring in the 1970s set the stage for the era of intensive insulin therapy, leading to a substantial reduction in the risk of long-term complications from diabetes. The tradeoff with intensive diabetes management is a marked increase in episodes of severe hypoglycemia. Real-time continuous glucose monitoring, a technology first approved by the Food and Drug Administration in 2005, helps to address this therapeutic challenge.In this issue of the Journal, Bergenstal et al.1 report the . . .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Cited by
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Insulin therapy and hypoglycemia
McCall, A. L. (2012) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2012.03.001 · Cited by 177
Evolution of Devices in Diabetes Management
Penfornis, A., Personeni, E., & Borot, S. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0058 · Cited by 49
Minder, A. E., Albrecht, D., Schäfer, J., & Zulewski, H. (2013) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2012.12.024 · Cited by 28
Metadata
- Authors
- Wolpert, H. A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2010-07-22
- Volume
- 363
- Issue
- 4
- Pages
- 383-384
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2045180452
- Cited by
- 26
- References
- 3
- FWCI
- 2.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring — Coming of Age. https://app.cochat.ai/papers/10.1056/nejme1006098
- The paper
- Wolpert, H. A. (2010). Continuous Glucose Monitoring — Coming of Age. New England Journal of Medicine. https://doi.org/10.1056/nejme1006098
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.