The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Device Thrombosis with Bioresorbable Scaffolds
Abstract
The development of coronary-artery stents was a major advance in interventional cardiology. However, conventional stents, which are metallic, cage-like structures, have some limitations — notably, they leave a permanent implant, which may prevent favorable arterial remodeling and preclude future surgical revascularization. Bioresorbable scaffolds were developed to overcome some of the disadvantages of metallic stents in that they gradually degrade in the body over time and leave no residual implant.1 The Absorb everolimus-eluting bioresorbable vascular scaffold (Abbott Vascular) was approved for use by the Food and Drug Administration (FDA) in July 2016.The largest trial of the Absorb bioresorbable scaffold was . . .
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pure PLLA is known to require over a year for resorption.
“it is known to require over a year for resorption [1, 6, 8, 15, 16].”
From Tuning structural relaxations, mechanical properties, and degradation timescale of PLLA during hydrolytic degradation by blending with PLCL-PEG (2019) · cites this paper as [6]
PLLA degrades slowly, with typical resorption taking several years.
“typical PLLA resorption can take several years [1, 6, 8, 15, 16].”
From Tuning structural relaxations, mechanical properties, and degradation timescale of PLLA during hydrolytic degradation by blending with PLCL-PEG (2019) · cites this paper as [6]
Citations
Cites
Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease
Ellis, S. G., Kereiakes, D. J., Metzger, D. C., Caputo, R. P., Rizik, D. G., Teirstein, P. S., Litt, M. R., Kini, A. S., Kabour, A., Marx, S. O., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509038 · Cited by 628
Serruys, P. W. J. C., Chevalier, B., Sotomi, Y., Cequier, A. R., Carrié, D., Piek, J. J., Boven, A. J. V., Dominici, M., Dudek, D., McClean, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)32050-5 · Cited by 540
Bioresorbable Scaffolds versus Metallic Stents in Routine PCI
Wykrzykowska, J. J., Kraak, R. P., Hofma, S. H., van der Schaaf, R. J., Arkenbout, E. K., Ijsselmuiden, A. J. J., Elias, J., van Dongen, I. M., Tijssen, R. Y. G., Koch, K. T., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1614954 · Cited by 452
Cassese, S., Byrne, R. A., Ndrepepa, G., Kufner, S., Wiebe, J., Repp, J., Schunkert, H., Fusaro, M., Kimura, T., & Kastrati, A. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00979-4 · Cited by 366
Stone, G. W., Gao, R., Kimura, T., Kereiakes, D. J., Ellis, S. G., Onuma, Y., Cheong, W., Jones-McMeans, J. M., Su, X., Zhang, Z., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)01039-9 · Cited by 267
Zhang, X.-L., Zhu, L., Wei, Z.-H., Zhu, Q.-Q., Qiao, J.-Z., Dai, Q., Huang, W., Li, X.-H., Xie, J., Kang, L.-N., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m16-0006 · Cited by 31
Flagged first, then by citations
Research works printed but not linked: 1
- Mukherjee D. Bioabsorbable stents. In: Topol EJ, Teirstein PS, eds. Textbook of interventional cardiology. 6th ed. Philadelphia: Saunders, 2011:432-441.
Cited by
Sorted by citations
Testa, L., Carlo, M. D., Petrolini, A., Rapetto, C., Varbella, F., Cortese, B., Gabrielli, G., Geraci, S., Loi, B., Boccuzzi, G., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-17-00254 · Cited by 134
Oliver, A. A., Sikora-Jasinska, M., Demir, A. G., & Guillory, R. J. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.03.058 · Cited by 111
Biodegradable Zwitterionic Polymer Coatings for Magnesium Alloy Stents
Ye, S., Chen, Y., Mao, Z., Gu, X., Shankarraman, V., Hong, Y., Shanov, V. N., & Wagner, W. R. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b01623 · Cited by 44
Mahmoud, A. N., Barakat, A. F., Elgendy, A. Y., Schneibel, E. J., Mentias, A. G., Abu‐Zaid, A., & Elgendy, I. Y. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.117.005286 · Cited by 40
Oosterbeek, R. N., Kwon, K.-A., Duffy, P., McMahon, S., Zhang, X. C., Best, S. M., & Cameron, R. E. (2019) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2019.109015 · Cited by 30
“This is as expected as it is known to require over a year for resorption [1, 6, 8, 15, 16].”
BackgroundMethodAmrute, J., Athanasiou, L. S., Nezami, F. R., Hernández, J. M. D. L. T., Camarero, T. G., & Edelman, E. R. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.3.036010 · Cited by 20
Oosterbeek, R. N., Zhang, X. C., Best, S. M., & Cameron, R. E. (2021) · Composites Science and Technology · doi:10.1016/j.compscitech.2021.109194 · Cited by 18
Galli, S., Troiano, S., Palloshi, A., Rapetto, C., Pisano, F., Aprigliano, G., Leoncini, M., Ravagnani, P. M., Maestro, M. D., & Montorsi, P. (2022) · Cardiovascular revascularization medicine · doi:10.1016/j.carrev.2022.01.020 · Cited by 15
Madanchi, M., Cioffi, G. M., Attinger‐Toller, A., Wolfrum, M., Moccetti, F., Seiler, T., Vercelli, L., Burkart, P., Toggweiler, S., Kobza, R., et al. (2021) · Open Heart · doi:10.1136/openhrt-2021-001776 · Cited by 14
The mechanisms of late scaffold thrombosis
Anadol, R., & Gori, T. (2017) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-179214 · Cited by 13
Fuchs‐Buder, T., Settembre, N., & Schmartz, D. (2018) · Der Anaesthesist · doi:10.1007/s00101-018-0464-z · Cited by 13
Innovations in management of cardiac disease: drugs, treatment strategies and technology
Foëx, P. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex327 · Cited by 13
Short communication: TNF-α and IGF-1 regulates epigenetic mechanisms of HDAC2 and HDAC10
Jiang, W., Block, M. E., & Boosani, C. S. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263190 · Cited by 10
Danzi, G. B., Bernelli, C., & Cerrato, E. (2019) · Cardiovascular revascularization medicine · doi:10.1016/j.carrev.2019.07.018 · Cited by 6
Gunawardena, T., Corballis, N. H., Merinopoulos, I., Tsampasian, V., Reinhold, J., Eccleshall, S., & Vassiliou, V. S. (2022) · BioMed · doi:10.3390/biomed2040035 · Cited by 5
Multiphysics Hemodynamic Behavior of Polylactic Acid-Based Stent: A Coupled Simulation Approach
Badal, R. M., Mohapatra, S., Bhoi, C., Sharma, N., Jena, S., & Panda, S. K. (2021) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4049967 · Cited by 4
A GPU parallelization scheme for 3D agent-based simulation of in-stent restenosis
Li, S., Lei, L., Hu, Y., He, Y., Sun, Y., & Zhou, Y. (2019) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs46900.2019.9114482 · Cited by 3
Optimal Treatment of Tapered Coronary Artery Lesions
Vashee, C., Mares, A. C., Lehker, A., & Mukherjee, D. (2022) · Angiology · doi:10.1177/00033197221127598 · Cited by 1
Perioperative Management of Dual Antiplatelet Therapy
Kounis, N. G., Koniari, I. C., Tsigkas, G., Chourdakis, E., Roumeliotis, A., Patsouras, N., Soufras, G. D., & Hahalis, G. N. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2017.11.032
Mazaev, V. P. (2021) · CARDIOVASCULAR THERAPY AND PREVENTION · doi:10.15829/1728-8800-2021-2930
Drug Coated Balloons for the Treatment of Coronary Artery Disease
Mukherjee, D. (2025) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2025.08.011
Pan, C., Gao, R., Wang, J., Zhou, C., Deng, L., & Pu, Y. (2026) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2026.102210
Metadata
- Authors
- Mukherjee, D.
- Affiliations
- Texas Tech University Health Sciences Center (US)
- Corresponding author
- Mukherjee, Debabrata
- ORCID
- Mukherjee, Debabrata
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2017-06-15
- Volume
- 376
- Issue
- 24
- Pages
- 2388-2389
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2601973560
- Cited by
- 22
- References
- 6
- Citations by year
- 2026: 1 · 2025: 1 · 2022: 4 · 2021: 5 · 2019: 3 · 2018: 3 · 2017: 5
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Antiplatelet Therapy and Cardiovascular Diseases
- Keywords
- device thrombosis, bioresorbable vascular scaffolds, Absorb scaffold, everolimus-eluting stent, coronary stents, arterial remodeling, revascularization, percutaneous coronary intervention
- MeSH terms
- Humans, Thrombosis, Absorbable Implants, Drug-Eluting Stents
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review