Cardiac Resynchronization in Chronic Heart Failure
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Previous studies have suggested that cardiac resynchronization achieved through atrial-synchronized biventricular pacing produces clinical benefits in patients with heart failure who have an intraventricular conduction delay. We conducted a double-blind trial to evaluate this therapeutic approach. METHODS: Four hundred fifty-three patients with moderate-to-severe symptoms of heart failure associated with an ejection fraction of 35 percent or less and a QRS interval of 130 msec or more were randomly assigned to a cardiac-resynchronization group (228 patients) or to a control group (225 patients) for six months, while conventional therapy for heart failure was maintained. The primary end points were the New York Heart Association functional class, quality of life, and the distance walked in six minutes. RESULTS: As compared with the control group, patients assigned to cardiac resynchronization experienced an improvement in the distance walked in six minutes (+39 vs. +10 m, P=0.005), functional class (P<0.001), quality of life (-18.0 vs. -9.0 points, P= 0.001), time on the treadmill during exercise testing (+81 vs. +19 sec, P=0.001), and ejection fraction (+4.6 percent vs. -0.2 percent, P<0.001). In addition, fewer patients in the group assigned to cardiac resynchronization than control patients required hospitalization (8 percent vs. 15 percent) or intravenous medications (7 percent vs. 15 percent) for the treatment of heart failure (P<0.05 for both comparisons). Implantation of the device was unsuccessful in 8 percent of patients and was complicated by refractory hypotension, bradycardia, or asystole in four patients (two of whom died) and by perforation of the coronary sinus requiring pericardiocentesis in two others. CONCLUSIONS: Cardiac resynchronization results in significant clinical improvement in patients who have moderate-to-severe heart failure and an intraventricular conduction delay.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While clinical improvements are generally achieved, six-month nonresponder rates have been reported to be as high as 32–43%11,13, which is partially attributed to anatomic constraints of lead positioning14.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [11]
In the citing paper
“About 30% of patients with impaired cardiac function have ventricular dyssynchrony and seek cardiac resynchronization therapy (CRT).”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [11]
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C., Garrigue, S., Kappenberger, L., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,751
Pitt, B., Poole-Wilson, P. A., Segal, R., Martinez, F. A., Dickstein, K., Camm, A. J., Konstam, M. A., Riegger, G., Klinger, G. H., Neaton, J., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02213-3 · Cited by 1,961
Pitt, B., Segal, R., Martinez, F. A., Meurers, G., Cowley, A. J., Thomas, I., Deedwania, P. C., Ney, D. E., Snavely, D. B., & Chang, P. I. (1997) · The Lancet · doi:10.1016/s0140-6736(97)01187-2 · Cited by 1,665
Aaronson, K. D., Schwartz, J. S., Chen, T.-M., Wong, K.-L., Goin, J. E., & Mancini, D. M. (1997) · Circulation · doi:10.1161/01.cir.95.12.2660 · Cited by 1,188
Auricchio, A., Stellbrink, C., Block, M., Sack, S., Vogt, J., Bakker, P., Klein, H., Kramer, A., Ding, J., Salo, R., et al. (1999) · Circulation · doi:10.1161/01.cir.99.23.2993 · Cited by 1,152
Kass, D. A., Chen, C.-H., Curry, C., Talbot, M., Berger, R., Fetics, B., & Nevo, E. (1999) · Circulation · doi:10.1161/01.cir.99.12.1567 · Cited by 972
Packer, M., Gheorghiade, M., Young, J. B., Costantini, P. J., Adams, K. F., Cody, R. J., Smith, L. K., Van Voorhees, L., Gourley, L. A., & Jolly, M. K. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307013290101 · Cited by 827
Self-citationPacker, M., Colucci, W. S., Sackner-Bernstein, J. D., Liang, C.-S., Goldscher, D. A., Freeman, I., Kukin, M. L., Kinhal, V., Udelson, J. E., Klapholz, M., et al. (1996) · Circulation · doi:10.1161/01.cir.94.11.2793 · Cited by 613
Self-citation
Research works printed but not linked: 4
- Brophy JM, 1994, Can J Cardiol, 10, 543
- Guyatt GH, 1985, Can Med Assoc J, 132, 919
- Naughton JP, Maider R. Methods of exercise testing. In: Naughton JP, Hellerstein HR, eds. Exercise testing and exercise training in coronary artery disease. New York: Academic Press, 1973:79-91.
- Rector RS, 1987, Heart Fail, 3, 198
Cited by
Items 801–900 of 1,008
Biventricular Pacing and Left Ventricular Pacing in Heart Failure:
Bordachar, P., Lafitte, S., Reuter, S., Garrigue, S., Sanders, P., Roudaut, R. P., Jaı̈s, P., Haı̈ssaguerre, M., & Clémenty, J. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04318.x · Cited by 56
Gold, M. R., Daubert, J., Abraham, W. T., Hassager, C., DINERMAN, J. L., Hudnall, J. H., Cerkvenik, J., & Linde, C. M. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000570 · Cited by 55
Self-citationConduction System Pacing for Cardiac Resynchronisation
Sharma, P. S., & Vijayaraman, P. (2021) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2020.45 · Cited by 56
Giraldi, F., Cattadori, G., Roberto, M., Carbucicchio, C., Pepi, M., Ballerini, G., Alamanni, F., Bella, P. E. D., Pontone, G., Andreini, D., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.02.065 · Cited by 55
Hyde, E., Behar, J. M., Claridge, S., Jackson, T., Lee, A., Remme, E. W., Sohal, M., Plank, G., Razavi, R., Rinaldi, C. A., et al. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.002677 · Cited by 55
Right ventricular systolic function and cardiac resynchronization therapy
Burri, H., Domenichini, G., Sunthorn, H., Fleury, E., Stettler, C., Foulkes, I., & Shah, D. C. (2009) · EP Europace · doi:10.1093/europace/eup401 · Cited by 55
“It is well established that cardiac resynchronization therapy (CRT) improves left ventricular ejection fraction (LVEF) in patients with heart failure.(1,2) However, the effect of CRT on right ventricular ejection fraction (RVEF) has not been well studied, owing to difficulty in measuring this parameter.”
Thijssen, J., Borleffs, C. J. W., Delgado, V., van Rees, J. B., Mooyaart, E. A. Q., van Bommel, R. J., van Erven, L., Boersma, E. H., Bax, J. J., & Schalij, M. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.038 · Cited by 55
Nguyen, H. V., Havalad, V., Aponte-Patel, L., Murata, A., Wang, D. Y., Rusanov, A., Cheng, B., Cabreriza, S. E., & Spotnitz, H. M. (2012) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.07.020 · Cited by 56
“Biventricular pacing (BiVP) is an established therapy for select patients with chronic congestive heart failure, improving clinical end points (symptoms, exercise capacity, quality of life, survival) and echocardiographic end points (systolic function, left ventricular size, mitral regurgitation).(14-17) Temporary BiV…”
Heart failure post-myocardial infarction: a review of the issues
Dargie, H. (2005) · Heart · doi:10.1136/hrt.2005.062018 · Cited by 54
Implications and Outcome of Permanent Coronary Sinus Lead Extraction and Reimplantation
Burke, M. C., Morton, J. B., LIN, A. C., TIERNEY, S., Desai, A. D., Hong, T. E., Kim, S. W., Salem, Y. S., Alberts, M., & Knight, B. P. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2005.40802.x · Cited by 55
Truong, Q. A., Januzzi, J. L., Szymonifka, J. D., Thai, W.-E., Wai, B., Lavender, Z. R., Sharma, U. C., Sandoval, R., Grunau, Z., Basnet, S., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.07.007 · Cited by 55
Schmidt, M. U., Brömsen, J., Herholz, C., Adler, K., Neff, F., Kopf, C., & Block, M. S. (2007) · EP Europace · doi:10.1093/europace/eul131 · Cited by 56
Cardiac resynchronization therapy utilization for heart failure: Findings from IMPROVE HF
Curtis, A. B., Yancy, C. W., Albert, N. M., Stough, W. G., Gheorghiade, M., Heywood, J. T., McBride, M. L., Mehra, M. R., O’Connor, C. M., REYNOLDS, D. W., et al. (2009) · American Heart Journal · doi:10.1016/j.ahj.2009.10.011 · Cited by 55
Kron, J., Aranda, J. M., Miles, W. M., Burkart, T. A., Woo, G. W., Saxonhouse, S. J., Sears, S. F., & CONTI, J. B. (2009) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9330-2 · Cited by 55
Hosseini, S. M., Moazzami, K., Rozen, G., Vaid, J., Saleh, A., Heist, E. K., Vangel, M. G., & Ruskin, J. N. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx100 · Cited by 55
Gasparini, M., Kloppe, A., Lunati, M., Anselme, F., Landolina, M., Martínez-Ferrer, J., Proclemer, A., Morani, G., Biffi, M., Ricci, R. P., et al. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.1117 · Cited by 55
Cardiac Implantable Electronic Device Therapy in Heart Failure
Hussein, A. A., & Wilkoff, B. L. (2019) · Circulation Research · doi:10.1161/circresaha.118.313571 · Cited by 60
Bleeker, G. B., Schalij, M. J., Molhoek, S. G., Boersma, E. H., Paul Steendijk, A., van der Wall, E. E., & Bax, J. J. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.03.091 · Cited by 55
Impact of race and gender on cardiac device implantations
El‐Chami, M. F., Hanna, I. R., Bush, H., & Langberg, J. J. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.07.024 · Cited by 55
Cazeau, S., Daubert, J., Tavazzi, L., Fröhlig, G., & Paul, V. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.02.007 · Cited by 55
Heinroth, K. M., Elster, M., Nuding, S., Schlegel, F., Christoph, A., Carter, J., Buerke, M., & Werdan, K. (2007) · EP Europace · doi:10.1093/europace/eum086 · Cited by 55
Bleeker, G. B., Schalij, M. J., Boersma, E. H., Holman, E. R., Paul Steendijk, A., van der Wall, E. E., & Bax, J. J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.07.068 · Cited by 55
Skouri, H. N., Girerd, N., Monzo, L., Petrie, M. C., Böhm, M., Adamo, M., Müllens, W., Savarese, G., Yılmaz, M. B., Amir, O., et al. (2025) · European Journal of Heart Failure · doi:10.1002/ejhf.3618 · Cited by 60
Fluoroscopically Guided Implantation of Modern Cardiac Resynchronization Devices
Perisinakis, K., Theocharopoulos, N., Damilakis, J. E., Manios, E. G., Vardas, P., & Gourtsoyiannis, N. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.070 · Cited by 54
The Use of Nuclear Imaging for Cardiac Resynchronization Therapy
Chen, J., Boogers, M. M., Bax, J. J., Soman, P., & Garcia, E. V. (2010) · Current Cardiology Reports · doi:10.1007/s11886-010-0086-9 · Cited by 54
Boriani, G., Gasparini, M., Landolina, M., Lunati, M., Proclemer, A., LONARDI, G., Iacopino, S., Rahue, W., Biffi, M., DiStefano, P., et al. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr046 · Cited by 57
Cardiovascular Disease in the Elderly
Jackson, C. F., & WENGER, N. K. (2011) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2011.05.003 · Cited by 78
Bonakdar, H. R., Jorat, M. V., Fazelifar, A., Alizadeh, A., Givtaj, N., Sameie, N., Sadeghpour, A., & Haghjoo, M. (2009) · EP Europace · doi:10.1093/europace/eup258 · Cited by 54
Morani, G., Gasparini, M., Zanon, F., Casali, E., Spotti, A., Reggiani, A., Bertaglia, E., Solimene, F., Molon, G., Accogli, M., et al. (2013) · EP Europace · doi:10.1093/europace/eut032 · Cited by 54
Persistence of secondary mitral regurgitation and response to cardiac resynchronization therapy
Cabrera‐Bueno, F., Molina-Mora, M. J., Alzueta, J., Peña-Hernández, J., Jiménez-Navarro, M. F., Fernández-Pastor, J., Barrera, A., & de Teresa, E. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep184 · Cited by 54
Valzania, C., Biffi, M., Martignani, C., Diemberger, I., Bertini, M., Ziacchi, M., Reggiani, M. L. B., Rocchi, G., Rapezzi, C., Branzi, A., et al. (2007) · Echocardiography · doi:10.1111/j.1540-8175.2007.00491.x · Cited by 54
Verbeek, X. A. A. M., Auricchio, A., Yu, Y., Ding, J., Pochet, T., Vernooy, K., Kramer, A., Spinelli, J., & Prinzen, F. W. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00641.2005 · Cited by 54
“PACING THERAPY for patients with heart failure (HF) and conduction disorders acutely improves left ventricular (LV) pump function (4, 13) and also results in long-term benefit (1, 5, 10).”
Gabor, S., Prenner, G., Wasler, A., Schweiger, M., Tscheliessnigg, K. H., & Smolle-Jüttner, F. M. (2005) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2005.08.026 · Cited by 54
Mangiavacchi, M., Gasparini, M., Faletra, F. F., Klersy, C., Morenghi, E., Galimberti, P., Genovese, L., Regoli, F. D., Chiara, F. D., Bragato, R., et al. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.08.008 · Cited by 59
Kleijn, S. A., van Dijk, J., de Cock, C. C., Allaart, C. P., van Rossum, A. C., & Kamp, O. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.06.012 · Cited by 53
Response to Cardiac Resynchronization Therapy in Patients with Heart Failure and Renal Insufficiency
ADELSTEIN, E. C., Shalaby, A. A., & Saba, S. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02705.x · Cited by 53
Device Therapy in Heart Failure Patients With Chronic Kidney Disease
Cannizzaro, L., Piccini, J. P., Patel, U. D., & Hernandez, A. F. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.05.024 · Cited by 53
Gula, L. J., Ames, A., WOODBURN, A., MAtkins, J., McCORMICK, M., BELL, J., SINK, D., McConville, J. W., & Epstein, L. M. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00163.x · Cited by 53
Lenarczyk, R., Kowalski, O., Kukulski, T., Szulik, M., Pruszkowska‐Skrzep, P., Zielinska, T., Kowalczyk, J. P., Pluta, S., Duszańska, A., Średniawa, B., et al. (2007) · EP Europace · doi:10.1093/europace/eum140 · Cited by 53
Tatsumi, K., Tanaka, H., Tsuji, T., Kaneko, A., Ryo, K., Yamawaki, K., Omar, A. M., Fukuda, Y., Norisada, K., Matsumoto, K., et al. (2011) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-9-11 · Cited by 53
“CRT is an established therapeutic option for HF patients with severe symptoms and a wide QRS complex [1-8].”
Tigen, K., Karaahmet, T., Gürel, E., Çevik, C., NUGENT, K. M., Pala, S., Tanalp, A. C., Mutlu, B., & Başaran, Y. (2009) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(09)70137-0 · Cited by 53
Delgado-Montero, A., Tayal, B., Goda, A., Ryo, K., Marek, J. J., Sugahara, M., Qi, Z., Althouse, A. D., Saba, S., SCHWARTZMAN, D. S., et al. (2016) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.115.004241 · Cited by 53
Packer, M. (2016) · Circulation · doi:10.1161/circulationaha.116.023538 · Cited by 55
Self-citationKurdekar, A. D., Chunduri, L. A. A., Chelli, S. M., Setty, M. K. H. G., Bulagonda, E. P., Zheng, J., HEWLETT, I. K., & Kamisetti, V. (2017) · RSC Advances · doi:10.1039/c6ra28737a · Cited by 54
Endpoints in Heart Failure Drug Development
Fiuzat, M., Lowy, N., Stockbridge, N., Sbolli, M., Latta, F., Lindenfeld, J., Lewis, E. F., Abraham, W. T., Teerlink, J. R., Walsh, M. N., et al. (2020) · JACC Heart Failure · doi:10.1016/j.jchf.2019.12.011 · Cited by 62
Self-citationRacial/Ethnic and Gender Disparities in Heart Failure with Reduced Ejection Fraction
Mwansa, H., Lewsey, S., Mazimba, S., & Breathett, K. (2021) · Current Heart Failure Reports · doi:10.1007/s11897-021-00502-5 · Cited by 51
Whinnett, Z. I., Shun-Shin, M. J., Tanner, M. A., Foley, P. W. X., Chandrasekaran, B., Moore, P., Adhya, S., Qureshi, N. A., Muthumala, A. G., Lane, R., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2736 · Cited by 53
Temporary epicardial pacing after cardiac surgery: a practical review
Reade, M. C. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.04951.x · Cited by 53
Management of Heart Failure After Cardiac Resynchronization Therapy
Aranda, J. M., Woo, G. W., Schofield, R. S., Handberg, E. M., Hill, J. A., Curtis, A. B., Sears, S. F., Goff, J. S., Pauly, D. F., & CONTI, J. B. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.078 · Cited by 58
Boriani, G., Regoli, F. D., Saporito, D., Martignani, C., Toselli, T., Biffi, M., Francolini, G., Diemberger, I., Reggiani, M. L. B., Rapezzi, C., et al. (2006) · Peptides · doi:10.1016/j.peptides.2006.02.010 · Cited by 53
Resynchronization/defibrillation for ambulatory heart failure trial: rationale and trial design
Tang, A. S., Wells, G. A., Arnold, M., Connolly, S., Hohnloser, S., Nichol, G., Rouleau, J., Sheldon, R., & Talajic, M. (2009) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e32831bc63b · Cited by 53
Cardiac Resynchronization Therapy
Abraham, W. T. (2006) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2005.11.001 · Cited by 53
Self-citationWalsh, R. G. (2005) · Heart Failure Reviews · doi:10.1007/s10741-005-4637-x · Cited by 53
JCS/JHFS 2025 Guideline on Diagnosis and Treatment of Heart Failure
Kitai, T., Kohsaka, S., Kato, T., Kato, E. T., Sato, K., TERAMOTO, K., Yaku, H., Akiyama, E., Ando, M., Izumi, C., et al. (2025) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2025.02.014 · Cited by 67
Gelfman, L. P., Kalman, J., & Goldstein, N. E. (2014) · Journal of Palliative Medicine · doi:10.1089/jpm.2013.0675 · Cited by 58
Foley, P. W. X., Patel, K., Irwin, N., Sanderson, J. E., Frenneaux, M. P., Smith, R. E. A., Stegemann, B., & Leyva, F. (2011) · Heart · doi:10.1136/hrt.2010.208355 · Cited by 52
Ginks, M., Duckett, S. G., Kapetanakis, S., Bostock, J., Hamid, S., Shetty, A., Ma, Y., Rhode, K., Carr‐White, G., Razavi, R., et al. (2011) · EP Europace · doi:10.1093/europace/eur336 · Cited by 52
Lindvall, C. J., Chatterjee, N. A., Chang, Y., Chernack, B., Jackson, V. A., Singh, J. P., & Metlay, J. P. (2015) · Circulation · doi:10.1161/circulationaha.115.018830 · Cited by 54
Cardiac resynchronization therapy in adults with congenital heart disease
Koyak, Z., de Groot, J. R., Krimly, A., Mackay, T. M., Bouma, B. J., Silversides, C. K., Oechslin, E. N., Höke, U., van Erven, L., Budts, W., et al. (2016) · EP Europace · doi:10.1093/europace/euw386 · Cited by 52
Kautzner, J., Riedlbauchová, L., Cihak, R. J., BYTESNIK, J., & Vančura, V. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00529.x · Cited by 52
Szilágyi, S., Merkely, B. P., Róka, A., Zima, E., Fülöp, G., Kutyifa, V., Szűcs, G., Becker, D. J., Apor, A., & Gellér, L. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00722.x · Cited by 52
Kára, T., Novák, M., Nykodym, J., Bybee, K. A., Meluzı́n, J., Orban, M., Nováková, Z., Lipoldová, J., Hayes, D. L., Soucek, M., et al. (2008) · CHEST Journal · doi:10.1378/chest.07-2832 · Cited by 52
Self-citationWorldwide Utilization of Implantable Cardioverter/Defibrillators Now and in the Future
Seidl, K., & Senges, J. (2003) · Cardiac Electrophysiology Review · doi:10.1023/a:1023603118860 · Cited by 52
“Although the effects biventricular pacing on overall survival are still under investigation, this pacing modality is of proven efficacy in improving quality of life and excise capacity in patients with severe heart failure (New York heart class III to IV) and wide QRS-complex [47,48].”
BackgroundLyu, H., John, M., Burkland, D., Greet, B., Post, A., Babakhani, A., & Razavi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-59017-z · Cited by 51
Long-Term Outcomes of Resynchronization–Defibrillation for Heart Failure
Sapp, J. L., Sivakumaran, S. T., Redpath, C. J., Khan, H. R., Parkash, R., Exner, D. V., Healey, J. S., Thibault, B., Sterns, L. D., Lam, N. H., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2304542 · Cited by 55
Cardiac Resynchronization Therapy: Do Women Benefit More Than Men?
XU, Y., Friedman, P. A., Webster, T. L., Brooke, K. L., Hodge, D. O., Wiste, H. J., Hua, W., Zhang, S., Hayes, D. L., & Cha, Y. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02168.x · Cited by 51
“Echocardiographic assessment included (1) LVEF; (2) left ventricular end-diastolic dimension (LVEDD); (3) mitral regurgitation (MR) severity (0 = none or trivial, 1 = mild, 2 = moderate, 3 = severe); and (4) pulmonary artery systolic pressure (PASP) estimated on the basis of the transtricuspid maximal regurgitant flow…”
MethodSelf-citationLip, G. Y. H., Heinzel, F. R., Gaïta, F., González‐Juanatey, J. R., Heuzey, J. Y. L., Potpara, T., Svendsen, J. H., Vos, M. A., Anker, S. D., Coats, A. J. S., et al. (2015) · European Journal of Heart Failure · doi:10.1002/ejhf.338 · Cited by 53
“Among patients having an indication for an ICD, a CRT-D device is recommended in those also having symptoms of HF of NYHA Class II, III, or ambulatory IV, an LVEF of ≤35%, and a QRS duration of ≥120 ms, as evident from various CRT studies summarized in Supplementary material online, Table S4.”
MethodPredictors and Outcomes of “Super-response” to Cardiac Resynchronization Therapy
Killu, A. M., Grupper, A., Friedman, P. A., Powell, B. D., Asirvatham, S. J., Espinosa, R. E., Luria, D. M., Rozen, G., Buber, J., Lee, Y., et al. (2014) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2014.03.001 · Cited by 51
Abraham, W. T., León, A. R., Sutton, M. G. S. J., Keteyian, S. J., Fieberg, A. M., Chinchoy, E., & Haas, G. J. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.07.026 · Cited by 51
Self-citationWessler, B. S., Kramer, D. G., Kelly, J. L., Trikalinos, T. A., Kent, D. M., Konstam, M. A., & Udelson, J. E. (2011) · Circulation Heart Failure · doi:10.1161/circheartfailure.111.961573 · Cited by 51
Sommer, A., Kronborg, M. B., Nørgaard, B. L., Gerdes, C., Mortensen, P. T., & Nielsen, J. C. (2014) · EP Europace · doi:10.1093/europace/euu056 · Cited by 51
“However, a large proportion of patients do not experience a beneficial response to this pacing strategy.(2,3) Consequently, extensive research has been conducted to identify predictors of a favourable clinical outcome.”
BackgroundBarra, S., Providencia, R. A., Narayanan, K., Bovéda, S., Duehmke, R. M., Garcia, R., Leyva, F., Roger, V. L., Jouven, X., Agarwal, S., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz773 · Cited by 51
Nagakura, T., Takeuchi, M., Yoshitani, H., Nakai, H., Nishikage, T., Kokumai, M., Otani, S., Yoshiyama, M., & Yoshikawa, J. (2007) · Echocardiography · doi:10.1111/j.1540-8175.2007.00458.x · Cited by 51
Atrial Fibrillation Burden During the Post‐Implant Period After CRT Using Device‐Based Diagnostics
Hügl, B. J., BRUNS, H., UNTERBERG‐BUCHWALD, C., Große, A., Stegemann, B., Lauer, B., Geller, J. C., & Gasparini, M. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00482.x · Cited by 51
“(2) AF burden reduces over time during the first 3 months after CRT implantation.”
BackgroundCowburn, P. J., Patel, H., Jolliffe, R. E., Wald, R. W., & Parker, J. D. (2005) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2004.11.005 · Cited by 51
“with moderate/severe heart failure and a broad QRS complex [3,4].”
Optimizing sequential biventricular pacing using radionuclide ventriculography
Burri, H., Sunthorn, H., Somsen, G. A., Zaza, S., Fleury, E., Shah, D. C., & Righetti, A. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.05.017 · Cited by 51
Cardiac Resynchronization Therapy for Heart Failure
Bax, J. J., van der Wall, E. E., & Schalij, M. J. (2002) · New England Journal of Medicine · doi:10.1056/nejm200211283472216 · Cited by 51
Dual-Site Left Ventricular Cardiac Resynchronization Therapy
Padeletti, L., Colella, A., Michelucci, A., Pieragnoli, P., Ricciardi, G., Porciani, M. C., Tronconi, F., Hettrick, D. A., & Valsecchi, S. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.08.016 · Cited by 50
D’Andrea, A., Salerno, G., Scarafile, R., Riegler, L., Gravino, R., Castaldo, F., Cocchia, R., Limongelli, G., Romanò, M., Calabrò, P., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02434.x · Cited by 50
Prevention, Diagnosis, and Treatment of Hypertensive Heart Disease
Georgiopoulou, V. V., Kalogeropoulos, A. P., Raggi, P., & Butler, J. (2010) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.005 · Cited by 59
Maurer, M. S., Teruya, S. L., Chakraborty, B., Helmke, S. T., & MANCINI, D. M. (2012) · Circulation Heart Failure · doi:10.1161/circheartfailure.112.969717 · Cited by 55
Crozier, A., Blazevic, B., Lamata, P., Plank, G., Ginks, M., Duckett, S. G., Sohal, M., Shetty, A., Rinaldi, C. A., Razavi, R., et al. (2015) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2015.10.026 · Cited by 50
Atrial Support Pacing in Heart Failure: Results from the Multicenter PEGASUS CRT Trial
Martin, D. O., DAY, J. D., Lai, P. Y., Murphy, A. L., Nayak, H. M., Villareal, R. P., Weiner, S., Kraus, S. M., Stolen, K. Q., & Gold, M. R. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02402.x · Cited by 50
“Worsened n (%) 112 (25) 123 (28) 117 (27) Death 11 (2) 17 (4) 19 (4) HF event then death 5 (1) 7 (2) 5 (1) HF event 48 (11) 47 (11) 38 (9) Worsened in global assessment 3 (1) 5 (1) 7 (2) Worsened in NYHA class 42 (10) 44 (10) 42 (10) Worsened in global assessment or NYHA class 3 (1) 3 (1) 6 (1)”
Thibault, B., Ritter, P., Bode, K., Calò, L., Mondesert, B. A., Mangual, J. O., Badie, N., McSpadden, L. C., Pappone, C., & Varma, N. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.01.020 · Cited by 50
(2008), G. D. T. D. L. E. P. E. D. Y. T. D. L. I. C. A. Y. C., & Desarrollada en colaboración con la Heart Failure Association (HFA) de la ESC y aprobada por la European Society of Intensive Care Medicine (ESICM) (2008) · Revista Española de Cardiología · doi:10.1016/s0300-8932(08)75740-3 · Cited by 83
McSwain, R. L., Schwartz, R. A., DeLurgio, D. B., Mera, F. V., Langberg, J. J., & León, A. R. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.40719.x · Cited by 50
Self-citationVarma, N., Jia, P., & Rudy, Y. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2007.06.017 · Cited by 50
PUGLISI, A., Maurizio, L., Marullo, A. G. M., Bianchi, S., Feccia, M., Sgreccia, F., Vicini, I., Valsecchi, S., Musumeci, F., & Vitali, E. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.04.016 · Cited by 53
Steinhaus, D. M., REYNOLDS, D. W., Gadler, F., Kay, G. N., HESS, M., Bennett, T., & For The Chronicle Investigators (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00176.x · Cited by 50
Sohal, M., Shetty, A., Niederer, S., Lee, A., Chen, Z., Jackson, T., Behar, J. M., Claridge, S., Bostock, J., Hyde, E., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.07.012 · Cited by 49
Gorcsan, J., Søgaard, P., Bax, J. J., Singh, J. P., Abraham, W. T., BORER, J. S., Dickstein, K., Gras, D., Krum, H., Brugada, J., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv418 · Cited by 49
Self-citationClinical response of cardiac resynchronization therapy in the elderly
Delnoy, P. P. H. M., Ottervanger, J. P., Luttikhuis, H. O., Elvan, A., Misier, A. R. R., Beukema, W. P., & van Hemel, N. M. (2008) · American Heart Journal · doi:10.1016/j.ahj.2007.11.009 · Cited by 49
Crossley, G. H., Biffi, M., Johnson, B., LIN, A. C., Gras, D., Hussin, A., Cuffio, A., Collier, J., El‐Chami, M. F., Li, S., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.12.019 · Cited by 49
Rickard, J., Cheng, A., SPRAGG, D. D., Cantillon, D. J., Chung, M. K., Tang, W. H. W., Wilkoff, B. L., & Varma, N. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.09.018 · Cited by 55
Ruwald, M. H., Ruwald, A., Jøns, C., Alexis, J. D., McNitt, S. A., Zaręba, W., & Moss, A. J. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.01.020 · Cited by 53
Implantable cardioverter defibrillators and cardiac resynchronisation therapy
Holzmeister, J., & Leclercq, C. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61228-2 · Cited by 59
Roubíček, T., Wichterle, D., Kucera, P., Nedbal, P., Kupec, J., Sedlakova, J., Černý, J., Štros, J., Kautzner, J., & Polášek, R. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003004 · Cited by 49
Kloppe, A., Lawo, T., Mijić, D., Schiedat, F., Muegge, A., & Lemke, B. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.02.001 · Cited by 49
Cheung, J. W., Ip, J. E., Markowitz, S. M., Liu, C. F., Thomas, G., Feldman, D. N., Swaminathan, R. V., Lerman, B. B., & Kim, L. K. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.02.017 · Cited by 49
Slotwiner, D. J., Raitt, M. H., Del-Carpio Munoz, F., Mulpuru, S. K., Nasser, N., & Peterson, P. N. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.035 · Cited by 49
Metadata
- Authors
- Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., Ellestad, M., Trupp, R. J., Underwood, J., Pickering, F., Truex, C., McAtee, P., & Messenger, J.
- Affiliations
- University of Kentucky (US)
- Emory University (US)
- University of Pennsylvania (US)
- Columbia University (US)
- Mayo Clinic (US)
- MemorialCare Long Beach Medical Center (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2002-06-13
- Volume
- 346
- Issue
- 24
- Pages
- 1845-1853
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2047198412
- Cited by
- 4,648
- References
- 35
- Citations by year
- 2026: 53 · 2025: 74 · 2024: 97 · 2023: 128 · 2022: 96 · 2021: 118 · 2020: 128 · 2019: 116 · 2018: 138 · 2017: 180 · 2016: 176 · 2015: 175 · 2014: 205 · 2013: 215 · 2012: 224
- FWCI
- 157.41
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- cardiac resynchronization therapy, chronic heart failure, intraventricular conduction delay, QRS duration, ejection fraction, NYHA functional class, 6-minute walk distance, quality of life, hospitalization, implantable cardioverter-defibrillator complications
- MeSH terms
- Aged, Cardiac Pacing, Artificial, Double-Blind Method, Female, Heart Failure, Hospitalization, Humans, Male, Middle Aged, Pacemaker, Artificial, Quality of Life, Stroke Volume, Survival Analysis, Exercise Tolerance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.