Cardiac Resynchronization in Chronic Heart Failure
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Previous studies have suggested that cardiac resynchronization achieved through atrial-synchronized biventricular pacing produces clinical benefits in patients with heart failure who have an intraventricular conduction delay. We conducted a double-blind trial to evaluate this therapeutic approach. METHODS: Four hundred fifty-three patients with moderate-to-severe symptoms of heart failure associated with an ejection fraction of 35 percent or less and a QRS interval of 130 msec or more were randomly assigned to a cardiac-resynchronization group (228 patients) or to a control group (225 patients) for six months, while conventional therapy for heart failure was maintained. The primary end points were the New York Heart Association functional class, quality of life, and the distance walked in six minutes. RESULTS: As compared with the control group, patients assigned to cardiac resynchronization experienced an improvement in the distance walked in six minutes (+39 vs. +10 m, P=0.005), functional class (P<0.001), quality of life (-18.0 vs. -9.0 points, P= 0.001), time on the treadmill during exercise testing (+81 vs. +19 sec, P=0.001), and ejection fraction (+4.6 percent vs. -0.2 percent, P<0.001). In addition, fewer patients in the group assigned to cardiac resynchronization than control patients required hospitalization (8 percent vs. 15 percent) or intravenous medications (7 percent vs. 15 percent) for the treatment of heart failure (P<0.05 for both comparisons). Implantation of the device was unsuccessful in 8 percent of patients and was complicated by refractory hypotension, bradycardia, or asystole in four patients (two of whom died) and by perforation of the coronary sinus requiring pericardiocentesis in two others. CONCLUSIONS: Cardiac resynchronization results in significant clinical improvement in patients who have moderate-to-severe heart failure and an intraventricular conduction delay.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While clinical improvements are generally achieved, six-month nonresponder rates have been reported to be as high as 32–43%11,13, which is partially attributed to anatomic constraints of lead positioning14.”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [11]
In the citing paper
“About 30% of patients with impaired cardiac function have ventricular dyssynchrony and seek cardiac resynchronization therapy (CRT).”
From Synchronized Biventricular Heart Pacing in a Closed-chest Porcine Model based on Wirelessly Powered Leadless Pacemakers (2020) · cites this paper as [11]
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C., Garrigue, S., Kappenberger, L., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,751
Pitt, B., Poole-Wilson, P. A., Segal, R., Martinez, F. A., Dickstein, K., Camm, A. J., Konstam, M. A., Riegger, G., Klinger, G. H., Neaton, J., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02213-3 · Cited by 1,961
Pitt, B., Segal, R., Martinez, F. A., Meurers, G., Cowley, A. J., Thomas, I., Deedwania, P. C., Ney, D. E., Snavely, D. B., & Chang, P. I. (1997) · The Lancet · doi:10.1016/s0140-6736(97)01187-2 · Cited by 1,665
Aaronson, K. D., Schwartz, J. S., Chen, T.-M., Wong, K.-L., Goin, J. E., & Mancini, D. M. (1997) · Circulation · doi:10.1161/01.cir.95.12.2660 · Cited by 1,188
Auricchio, A., Stellbrink, C., Block, M., Sack, S., Vogt, J., Bakker, P., Klein, H., Kramer, A., Ding, J., Salo, R., et al. (1999) · Circulation · doi:10.1161/01.cir.99.23.2993 · Cited by 1,152
Kass, D. A., Chen, C.-H., Curry, C., Talbot, M., Berger, R., Fetics, B., & Nevo, E. (1999) · Circulation · doi:10.1161/01.cir.99.12.1567 · Cited by 972
Packer, M., Gheorghiade, M., Young, J. B., Costantini, P. J., Adams, K. F., Cody, R. J., Smith, L. K., Van Voorhees, L., Gourley, L. A., & Jolly, M. K. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307013290101 · Cited by 827
Self-citationPacker, M., Colucci, W. S., Sackner-Bernstein, J. D., Liang, C.-S., Goldscher, D. A., Freeman, I., Kukin, M. L., Kinhal, V., Udelson, J. E., Klapholz, M., et al. (1996) · Circulation · doi:10.1161/01.cir.94.11.2793 · Cited by 613
Self-citation
Research works printed but not linked: 4
- Brophy JM, 1994, Can J Cardiol, 10, 543
- Guyatt GH, 1985, Can Med Assoc J, 132, 919
- Naughton JP, Maider R. Methods of exercise testing. In: Naughton JP, Hellerstein HR, eds. Exercise testing and exercise training in coronary artery disease. New York: Academic Press, 1973:79-91.
- Rector RS, 1987, Heart Fail, 3, 198
Cited by
Items 301–400 of 1,008
Cardiac Resynchronization Therapy: Current State of the Art
Auricchio, A., & Abraham, W. T. (2004) · Circulation · doi:10.1161/01.cir.0000115583.20268.e1 · Cited by 171
“Mechanisms of Action of CRT At the present time, we recognize 4 levels of electromechanical abnormalities that may be treated by CRT (Figure 3), as follows: (1) atrioventricular delay, (2) interventricular delay, (3) intraventricular delay, and (4) the most recently described13 intramural delay.”
MethodSelf-citationImpact of Coronary Sinus Lead Position on Biventricular Pacing:
Rossillo, A., Verma, A., Saad, E., CORRADO, A., GASPARINI, G., Marrouche, N. F., Golshayan, A., McCurdy, R. R., Bhargava, M., Khaykin, Y., et al. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04089.x · Cited by 152
Turner, M., Bleasdale, R. A., Vinereanu, D., Mumford, C. E., Paul, V., Fraser, A. G., & Frenneaux, M. P. (2004) · Circulation · doi:10.1161/01.cir.0000131184.40893.40 · Cited by 152
Dohi, K., Suffoletto, M. S., SCHWARTZMAN, D. S., Ganz, L. I., Pinsky, M. R., & Gorcsan, J. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.03.032 · Cited by 151
Achilli, A., Peraldo, C., Sassara, M., Orazi, S., Bianchi, S., Laurenzi, F., DONATI, R., Perego, G. B., Spampinato, A., Valsecchi, S., et al. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00486.x · Cited by 150
“The 30% nonresponder rate to CRT is high,2 and is probably related to several factors: (1) The indirect and inaccurate estimation of mechanical LV dyssynchrony, based on QRS duration; (2) the lack of adequate resynchronization, possibly due to inappropriate LV pacing site; (3) suboptimal device programming; (4) the pr…”
BackgroundPappone, C., Ćalović, Ž., Vicedomini, G., Cuko, A., McSpadden, L. C., Ryu, K., Romano, E., Saviano, M., Baldi, M., Pappone, A., et al. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.11.023 · Cited by 150
The rationale and emergence of electroconductive biomaterial scaffolds in cardiac tissue engineering
Solazzo, M., O’Brien, F. J., Nicolosi, V., & Monaghan, M. G. (2019) · APL Bioengineering · doi:10.1063/1.5116579 · Cited by 155
2013 ACCF/ACR/ASE/ASNC/SCCT/SCMR Appropriate Utilization of Cardiovascular Imaging in Heart Failure
Patel, M. R., White, R. D., Abbara, S., Bluemke, D. A., Herfkens, R. J., Picard, M., Shaw, L. J., Silver, M., Stillman, A. E., & Udelson, J. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.02.005 · Cited by 145
“Up to 30% of carefully selected HF candidates do not show benefit from CRT and possibly progressive worsening despite CRT (113,114).”
Integrating Palliative Care Into Heart Failure Care
Hauptman, P. J., & Havranek, E. P. (2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.4.374 · Cited by 147
Fung, J. W.-H., Yu, C.-M., Yip, G., Zhang, Y., Chan, H., Kum, C.-C., & Sanderson, J. E. (2003) · Heart · doi:10.1136/heart.90.1.17 · Cited by 149
Oldenburg, O., Schmidt, A., Lamp, B., Bitter, T., Muntean, B. G., Langer, C., & Horstkotte, D. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.04.007 · Cited by 149
“5 ml/kg/ min] in this study is of similar magnitude [30].”
BackgroundResultLópez‐Candales, A., Dohi, K., Bazaz, R. R., & Edelman, K. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.04.028 · Cited by 146
Non-contact left ventricular endocardial mapping in cardiac resynchronisation therapy
Lambiase, P. D., Rinaldi, C. A., Hauck, J., Mobb, M., Elliott, D., Mohammad, S., Gill, J. S., & Bucknall, C. A. (2003) · Heart · doi:10.1136/heart.90.1.44 · Cited by 146
ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Nielsen, J. C., Petersen, H. H., Karlsen, F. M., Chri, L. S., & Haarbo, J. (2014) · Cited by 146
Role of myocardial constructive work in the identification of responders to CRT
Galli, E., Leclercq, C., Hubert, A., Bernard, A., Smiseth, O. A., Mabo, P., Samset, E., Hernandez, A. I., & Donal, E. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex191 · Cited by 147
Tanaka, H., Hara, H., Saba, S., & Gorcsan, J. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.09.010 · Cited by 145
Cardiopulmonary Exercise Testing and Prognosis in Chronic Heart Failure*
Corrà, U., Mezzani, A., Bosimini, E., & Giannuzzi, P. (2004) · CHEST Journal · doi:10.1378/chest.126.3.942 · Cited by 144
Quality of Life and Left Ventricular Assist Device Support
MacIver, J., & Ross, H. J. (2012) · Circulation · doi:10.1161/circulationaha.111.040279 · Cited by 154
Influence of Left Ventricular Lead Location on Outcomes in the COMPANION Study
Saxon, L. A., Olshansky, B., VOLOSIN, K. J., Steinberg, J. S., Lee, B. K., TOMASSONI, G. F., Guarnieri, T., Rao, A., YONG, P., Galle, E. G., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01444.x · Cited by 142
ZANON, F., BARACCA, E., AGGIO, S., PASTORE, G., BOARETTO, G., CARDANO, P., MAROTTA, T., RIGATELLI, G., GALASSO, M., CARRARO, M., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00285.x · Cited by 144
Thibault, B., Ducharme, A., Harel, F., White, M., O’Meara, E., Guertin, M., Lavoie, J., Frasure‐Smith, N., Dubuc, M., Guerra, P. G., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.032904 · Cited by 142
Fruhwald, F. M., Fahrleitner-Pammer, A., Berger, R., Leyva, F., Freemantle, N., Erdmann, E., Gras, D., Kappenberger, L., Tavazzi, L., Daubert, J.-C., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl505 · Cited by 141
Understanding Nonresponders of Cardiac Resynchronization Therapy—Current and Future Perspectives
Yu, C., Fung, J. W., Zhang, Q., & Sanderson, J. E. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.40829.x · Cited by 142
Leclercq, C., Cazeau, S., LELLOUCHE, D., FOSSATI, F., Anselme, F., Davy, J., Sadoul, N., Klug, D., MOLLO, L., & Daubert, J. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00598.x · Cited by 153
“The patients were eligible for inclusion in the study if they fulfilled the following criteria: (1) New York Heart Association (NYHA) functional classes III or IV for ≥1 month despite optimized medical treatment, including diuretics, angiotensin-converting enzyme inhibitors, and beta-adrenergic blockers in the highest…”
BackgroundMethodDuckett, S. G., Ginks, M., Shetty, A., Bostock, J., Gill, J. S., Hamid, S., Kapetanakis, S., Cunliffe, E., Razavi, R., Carr‐White, G., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.04.042 · Cited by 140
“Cardiac resynchronization therapy improves quality of life (1,2), prognosis (3), and in the long-term is associated with left ventricular (LV) reverse remodeling (RR) (4).”
BackgroundPrevalence and risk factors related to infections of cardiac resynchronization therapy devices
Romeyer-Bouchard, C., Costa, A. D., Dauphinot, V., Messier, M., Bisch, L., Samuel, B., Lafond, P., Ricci, P., & Isaaz, K. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp421 · Cited by 144
“18–21 Cardiac resynchronization therapy infection rate and factors predicting these DRI are not well understood in this clinical setting with literature reporting from 1.3 to 7%.”
BackgroundInfluentialCardiac resynchronization therapy: a meta-analysis of randomized controlled trials
Wells, G. A., Parkash, R., Healey, J. S., Talajic, M. R., Arnold, J. M. O., Sullivan, S., Peterson, J., Yetisir, E., Theoret-Patrick, P., Luce, M., et al. (2011) · Canadian Medical Association Journal · doi:10.1503/cmaj.101685 · Cited by 140
Meta-analysis: Cardiac Resynchronization Therapy for Patients With Less Symptomatic Heart Failure
Al-Majed, N. S., McAlister, F. A., Bakal, J. A., & Ezekowitz, J. A. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-6-201103150-00313 · Cited by 139
Penn, M. S., Mendelsohn, F. O., Schaer, G. L., Sherman, W., FARR, M. A., Pastore, J., Rouy, D., Clemens, R., Aras, R. A., & Losordo, D. W. (2013) · Circulation Research · doi:10.1161/circresaha.111.300440 · Cited by 138
Thibault, B., Dubuc, M., Khairy, P., Guerra, P. G., Macle, L., Rivard, L., Roy, D., Talajic, M. R., Karst, E., Ryu, K., et al. (2013) · EP Europace · doi:10.1093/europace/eus435 · Cited by 137
Altenberger, J., Parissis, J., Costard‐Jäckle, A., Winter, A., Ebner, C., Karavidas, A. I., Sihorsch, K., Avgeropoulou, E., Weber, T., Dimopoulos, L., et al. (2014) · European Journal of Heart Failure · doi:10.1002/ejhf.118 · Cited by 151
Bozkurt, B., & Khalaf, S. Z. (2017) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-13-4-216 · Cited by 157
Leclercq, C., & Hare, J. M. (2004) · Circulation · doi:10.1161/01.cir.0000113458.76455.03 · Cited by 137
“MIRACLE N 453 (2) 1998–2000 Yes/parallel Yes 6 III/IV 3.”
Delnoy, P. P. H. M., Ottervanger, J. P., Luttikhuis, H. O., Elvan, A., Misier, A. R. R., Beukema, W. P., & van Hemel, N. M. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.12.040 · Cited by 136
Acute hemodynamic benefit of multisite ventricular pacing after congenital heart surgery
Zimmerman, F. J., Starr, J. P., Koenig, P., Smith, P., Hijazi, Z. M., & BACHA, E. A. (2003) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(03)00175-9 · Cited by 136
Long-term retention of cardiac resynchronization therapy
Knight, B. P., Desai, A. D., Coman, J. A., Faddis, M. N., & Yong, P. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.054 · Cited by 139
Electrical resynchronization induced by direct His-bundle pacing
Lustgarten, D. L., Calame, S., Crespo, E. M., Calame, J., Lobel, R. M., & Spector, P. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.09.066 · Cited by 135
Dickstein, K., Normand, C., Auricchio, A., Bogale, N., Cleland, J. G. F., Gitt, A. K., Stellbrink, C., Anker, S. D., Filippatos, G. S., Gasparini, M., et al. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.1142 · Cited by 144
Kusumoto, F. M., Calkins, H., Boehmer, J., Buxton, A. E., Chung, M. K., Gold, M. R., Hohnloser, S. H., Indik, J., Lee, R., Mehra, M. R., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000056 · Cited by 131
The anatomy of the coronary sinus venous system for the cardiac electrophysiologist
Habib, A., Lachman, N., Christensen, K., & Asirvatham, S. J. (2009) · EP Europace · doi:10.1093/europace/eup270 · Cited by 135
Stockburger, M., Gómez-Doblas, J. J., Lamas, G., Alzueta, J., Fernández-Lozano, I., Cobo, E., Wiegand, U., de la Concha, J. F., Navarro, X., Navarro-López, F., et al. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr041 · Cited by 134
van Gelder, B. M., Scheffer, M. G., Meijer, A., & Bracke, F. A. L. E. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.11.023 · Cited by 134
Right Ventricular Mechanics and QRS Duration in Patients With Repaired Tetralogy of Fallot
Uebing, A. S., Gibson, D. G., Babu‐Narayan, S. V., Diller, G., Dimopoulos, K., Göktekín, Ö., Spence, M. S., Andersen, K., Henein, M. Y., Gatzoulis, M. Α., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.688770 · Cited by 134
Cardiac pacing: the state of the art
Trohman, R. G., Kim, M. H., & Pinski, S. L. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17358-3 · Cited by 147
Cost-effectiveness of cardiac resynchronization therapy: results from the CARE-HF trial
Calvert, M., Freemantle, N., Yao, G., Cleland, J. G. F., Billingham, L. J., Daubert, J., & Bryan, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi662 · Cited by 133
Mair, H., Sachweh, J. S., Meuris, B., Nollert, G., Schmoeckel, M., Schuetz, A., Reichart, B., & Daebritz, S. H. (2004) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2004.09.029 · Cited by 132
Westenberg, J. J. M., Lamb, H. J., van der Geest, R. J., Bleeker, G. B., Holman, E. R., Schalij, M. J., Roos, A., van der Wall, E. E., Reiber, J. H. C., & Bax, J. J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.058 · Cited by 131
Chalil, S., Stegemann, B., Muhyaldeen, S., Khadjooi, K., Foley, P. W. X., Smith, R., & Leyva, F. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00841.x · Cited by 131
SPECT myocardial perfusion imaging for the assessment of left ventricular mechanical dyssynchrony
Chen, J., Garcia, E. V., Bax, J. J., Iskandrian, A. E., Borges‐Neto, S., & Soman, P. (2011) · Journal of Nuclear Cardiology · doi:10.1007/s12350-011-9392-x · Cited by 131
The Cardiovascular Disease Continuum Validated: Clinical Evidence of Improved Patient Outcomes
Dzau, V. J., Antman, E. M., Black, H. R., Hayes, D. L., Manson, J. E., Plutzky, J., Popma, J. J., & Stevenson, W. G. (2006) · Circulation · doi:10.1161/circulationaha.106.655761 · Cited by 158
Self-citationMagnetic Resonance Imaging Assessment of Ventricular Dyssynchrony
Lardo, A. C., Abraham, T. P., & Kass, D. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.015 · Cited by 130
“C a p c w c m espite the well-documented beneficial effects and overall fficacy of cardiac resynchronization therapy (CRT) (1,2), pproximately 20% to 30% of patients receiving CRT do ot demonstrate symptomatic improvement (3).”
BackgroundAbraham, W. T., Gras, D., Yu, C., Guzzo, L., & Gupta, M. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.02.034 · Cited by 129
Self-citationVannan, M. A., Pedrizzetti, G., Li, P., Gurudevan, S., Houle, H. C., Main, J., Jackson, J. I., & Nanda, N. C. (2005) · Echocardiography · doi:10.1111/j.1540-8175.2005.00172.x · Cited by 129
Beck, H., Boden, W. E., Patibandla, S., Kireyev, D., Gupta, V., Campagna, F., CAIN, M. E., & Marine, J. E. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.04.043 · Cited by 128
Congenital heart disease: the original heart failure syndrome
Bolger, A. P., Coats, A. J. S., & Gatzoulis, M. Α. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00005-8 · Cited by 136
Rohacek, M., Weisser, M., Kobza, R., Schoenenberger, A. W., Pfyffer, G. E., Frei, R., Erné, P., & Trampuž, A. (2010) · Circulation · doi:10.1161/circulationaha.109.906461 · Cited by 134
Sommer, A., Kronborg, M. B., Nørgaard, B. L., Poulsen, S. H., Bouchelouche, K., Bøttcher, M., Jensen, H. K., Jensen, J. M., Kristensen, J., Gerdes, C., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.530 · Cited by 127
“Adjacent 44 (50) 49 (54) Remote 1 (1) 2 (2) Scar at LV pacing site 3 (3) 2 (2) 0.”
InfluentialMoak, J. P., Hasbani, K., Ramwell, C. B., Freedenberg, V. A., BERGER, J. T., DiRusso, G. B., & Callahan, P. M. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00565.x · Cited by 127
Sundell, J., Engblom, E., Koistinen, J. M., Ylitalo, A., Naum, A. S., Stolen, K. Q., Kalliokoski, R., Nekolla, S. G., Airaksinen, J. K. E., Bax, J. J., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.044 · Cited by 126
Chung, E. S., Katra, R. P., Ghio, S., Bax, J., Gerritse, B., Hilpisch, K., Peterson, B. J., Feldman, D. S., & Abraham, W. T. (2010) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfq009 · Cited by 125
Self-citationBoogers, M. J., Chen, J., van Bommel, R. J., Borleffs, C. J. W., Dibbets‐Schneider, P., van der Hiel, B., Younis, I. A., Schalij, M. J., van der Wall, E. E., Garcia, E. V., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1621-z · Cited by 125
Woo, G. W., Petersen‐Stejskal, S., Johnson, J. W., CONTI, J. B., Aranda, J. A., & Curtis, A. B. (2005) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-005-6545-3 · Cited by 125
“The MIRACLE study design, patient population, methods and results have been published previously [1].”
InfluentialNytrøen, K., Rustad, L. A., Aukrust, P., Ueland, T., Hallén, J., Holm, I., Rolid, K., Lekva, T., Fiane, A. E., Amlie, J. P., et al. (2012) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2012.04221.x · Cited by 116
“5 mL equals 1 metabolic equivalent, and is greater than that found in most rehabilitation programs among HTx patients (4,15) or what has been observed with an introduction of ACE-inhibitors (16), beta blockers (17) or cardiac resynchronization therapy (18), among HF patients.”
Methodvan Deursen, C., van Geldorp, I. E., Rademakers, L. M., van Hunnik, A., Kuiper, M., Klersy, C., Auricchio, A., & Prinzen, F. W. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.846022 · Cited by 123
Bansal, S., Lindenfeld, J. M., & Schrier, R. W. (2009) · Circulation Heart Failure · doi:10.1161/circheartfailure.108.821199 · Cited by 128
Cardiac Electromechanical Models: From Cell to Organ
Trayanova, N. A., & Rice, J. J. (2011) · Frontiers in Physiology · doi:10.3389/fphys.2011.00043 · Cited by 124
Dhingra, R., Pencina, M. J., Wang, T. J., Nam, B.-H., Benjamin, E. J., Levy, D., Larson, M. G., Kannel, W. B., D’Agostino, R. B., & Vasan, R. S. (2006) · Hypertension · doi:10.1161/01.hyp.0000217141.20163.23 · Cited by 122
Damman, K., Tang, W. H. W., Felker, G. M., Lassus, J., Zannad, F., Krum, H., & McMurray, J. J. V. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.11.031 · Cited by 122
“However, the effect of therapy in these patients has not been reported (58,59,61,64).”
BackgroundD’Andrea, A., Caso, P., Romano, S., Scarafile, R., Riegler, L., Salerno, G., Limongelli, G., Salvo, G. D., Calabrò, P., Viscovo, L. D., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm443 · Cited by 121
Gadler, F., Valzania, C., & Linde, C. (2015) · Europace · doi:10.1093/europace/euu233 · Cited by 119
Bleeker, G. B., Schalij, M. J., Nihoyannopoulos, P., Paul Steendijk, A., Molhoek, S. G., van Erven, L., Bootsma, M., Holman, E. R., van der Wall, E. E., & Bax, J. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.04.069 · Cited by 120
Faggiano, P. M., D’Aloia, A., Gualeni, A., Brentana, L., & Cas, L. D. (2004) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2003.11.024 · Cited by 137
Kerlan, J. E., Sawhney, N. S., Waggoner, A. D., Chawla, M. K., Garhwal, S., Osborn, J. L., & Faddis, M. N. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2005.11.006 · Cited by 120
Leitlinien zur Herzschrittmachertherapie
Lemke, B., Nowak, B., & Pfeiffer, D. (2005) · Zeitschrift für Kardiologie · doi:10.1007/s00392-005-0269-3 · Cited by 139
“Durch die Resynchronisationstherapie konnte bei entsprechenden Patienten eine Verbesserung der Herzinsuffizienz, der Belastbarkeit, der Lebensqualität und der Überlebensrate nachgewiesen werden [A] [18, 20, 21, 22].”
BackgroundPouleur, A., Knappe, D., Shah, A. M., Uno, H., Bourgoun, M., Foster, E., McNitt, S. A., Hall, W. J., Zaręba, W., Goldenberg, I., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr185 · Cited by 119
Gold, M. R., Linde, C. M., Abraham, W. T., Gardiwal, A., & Daubert, J. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.12.031 · Cited by 119
Self-citationBogale, N., Witte, K. K., Priori, S. G., Cleland, J. G. F., Auricchio, A., Gadler, F., Gitt, A. K., Limbourg, T., Linde, C. M., & Dickstein, K. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr085 · Cited by 123
QRS Area Is a Strong Determinant of Outcome in Cardiac Resynchronization Therapy
van Stipdonk, A. M. W., Horst, I. A., Kloosterman, M., Engels, E. B., Rienstra, M., Crijns, H. J. G. M., Vos, M. A., Gelder, I. C. V., Prinzen, F. W., Meine, M., et al. (2018) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006497 · Cited by 118
Miyazaki, C., Powell, B. D., Bruce, C. J., Espinosa, R. E., Redfield, M. M., Miller, F. A., Hayes, D. L., Cha, Y., & Oh, J. K. (2008) · Circulation · doi:10.1161/circulationaha.107.733675 · Cited by 118
Self-citationEgoavil, C. A., Ho, R. T., Greenspon, A. J., & Pavri, B. B. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.03.012 · Cited by 118
Duncan, A. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00475-x · Cited by 118
Zwanenburg, J. J. M., Götte, M., Kuijer, J. P. A., Heethaar, R. M., van Rossum, A. C., & Marcus, J. T. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01047.2003 · Cited by 118
Mollema, S. A., Bleeker, G. B., van der Wall, E. E., Schalij, M. J., & Bax, J. J. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.06.071 · Cited by 118
“For example, the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) trial demonstrated that 32% of patients did not improve in NYHA class (1).”
BackgroundMethodResultSmith, L. A., Vennelle, M., Gardner, R. S., McDonagh, T. A., Denvir, M. A., Douglas, N. J., & Newby, D. E. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm131 · Cited by 120
Hsing, J. M., Selzman, K. A., Leclercq, C., Pires, L. A., McLaughlin, M. G., McRae, S., Peterson, B. J., & ZIMETBAUM, P. J. (2011) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.962605 · Cited by 118
The Benefit of Cardiac Resynchronization Therapy and QRS Duration: A Meta‐Analysis
Stavrakis, S., Lazzara, R., & Thadani, U. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02144.x · Cited by 117
“subject headings and keywords including: (1) CRT or cardiac pacing, (2) HF, and (3) randomized controlled trial.”
BackgroundRitter, P., Delnoy, P. P. H. M., Padeletti, L., Lunati, M., Naegele, H., Borri-Brunetto, A., & Silvestre, J. (2012) · EP Europace · doi:10.1093/europace/eus059 · Cited by 117
Long-term effects of cardiac resynchronisation therapy in patients with atrial fibrillation
Khadjooi, K., Foley, P. W. X., Chalil, S., Anthony, J., Smith, R. E. A., Frenneaux, M. P., & Leyva, F. (2008) · Heart · doi:10.1136/hrt.2007.129429 · Cited by 117
BACHA, E. A., Zimmerman, F. J., Mor‐Avi, V., Weinert, L., Starr, J. P., Sugeng, L., & Lang, R. M. (2004) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.04.065 · Cited by 117
Cleland, J. G. F., Calvert, M., Verboven, Y., & Freemantle, N. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.11.006 · Cited by 136
Tse, H., Turner, S. P., Sanders, P., Okuyama, Y., Fujiu, K., Cheung, C.-W., Russo, M. A., Green, M. D. S., Yiu, K., Chen, P., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.12.014 · Cited by 124
Brugada, J., Delnoy, P. P. H. M., Brachmann, J., REYNOLDS, D. W., Padeletti, L., Noelker, G., Kantipudi, C., López, J. M. R., Dichtl, W., Borri-Brunetto, A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw526 · Cited by 128
1-Year Outcomes for Transcatheter Repair in Patients With Mitral Regurgitation From the CLASP Study
Webb, J. G., Hensey, M., Szerlip, M., Schäfer, U., Cohen, G. N., Kar, S., Makkar, R., Kipperman, R., Spargias, K. S., O’Neill, W. W., et al. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.06.019 · Cited by 122
Cardiac resynchronization therapy (CRT): Clinical trials, guidelines, and target populations
Linde, C. M., Ellenbogen, K. A., & McAlister, F. A. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.04.026 · Cited by 116
Impact of cardiac resynchronization therapy on the severity of mitral regurgitation
Biase, L. D., Auricchio, A., Mohanty, P. K., Bai, R., Kautzner, J., Pieragnoli, P., Regoli, F. D., Sorgente, A., Spinucci, G., Ricciardi, G., et al. (2011) · EP Europace · doi:10.1093/europace/eur047 · Cited by 115
Trigo, M. D., Bergeron, S., Bernier, M., Amat-Santos, I. J., Puri, R., Campelo‐Parada, F., Altisent, O. A., Regueiro, A., Eigler, N. L., Rozenfeld, E., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00585-7 · Cited by 119
Self-citationRobotically assisted left ventricular epicardial lead implantation for biventricular pacing
DeRose, J. J., Ashton, R. C., Belsley, S., Swistel, D. G., Vloka, M. E., EHLERT, F. A., Shaw, R., Sackner‐Bernstein, J., Hillel, Z., & Steinberg, J. S. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00252-3 · Cited by 115
“However, technical limitations owing to individual coronary sinus (CS) and coronary venous anatomy result in a 10% to 15% failure rate of left ventricular (LV) lead placement and effective biventricular pacing (7,8).”
BackgroundFonarow, G. C., Yancy, C. W., Albert, N. M., Curtis, A. B., Stough, W. G., Gheorghiade, M., Heywood, J. T., Mehra, M. R., O’Connor, C. M., REYNOLDS, D. W., et al. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.03.030 · Cited by 119
I Diretriz Latino-Americana para avaliação e conduta na insuficiência cardíaca descompensada
Bocchi, E. A., Vilas‐Boas, F., Perrone, S. V., Caamaño, A. G., Clausell, N., Moreira, M. D. C. V., Thierer, J. M., Grancelli, H., Junior, C. V. S., de Albuquerque, D. C., et al. (2005) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2005002200001 · Cited by 142
Placebo and Nocebo in Cardiovascular Health
Olshansky, B. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.09.036 · Cited by 127
Metadata
- Authors
- Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., Ellestad, M., Trupp, R. J., Underwood, J., Pickering, F., Truex, C., McAtee, P., & Messenger, J.
- Affiliations
- University of Kentucky (US)
- Emory University (US)
- University of Pennsylvania (US)
- Columbia University (US)
- Mayo Clinic (US)
- MemorialCare Long Beach Medical Center (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2002-06-13
- Volume
- 346
- Issue
- 24
- Pages
- 1845-1853
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2047198412
- Cited by
- 4,648
- References
- 35
- Citations by year
- 2026: 53 · 2025: 74 · 2024: 97 · 2023: 128 · 2022: 96 · 2021: 118 · 2020: 128 · 2019: 116 · 2018: 138 · 2017: 180 · 2016: 176 · 2015: 175 · 2014: 205 · 2013: 215 · 2012: 224
- FWCI
- 157.41
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- cardiac resynchronization therapy, chronic heart failure, intraventricular conduction delay, QRS duration, ejection fraction, NYHA functional class, 6-minute walk distance, quality of life, hospitalization, implantable cardioverter-defibrillator complications
- MeSH terms
- Aged, Cardiac Pacing, Artificial, Double-Blind Method, Female, Heart Failure, Hospitalization, Humans, Male, Middle Aged, Pacemaker, Artificial, Quality of Life, Stroke Volume, Survival Analysis, Exercise Tolerance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.