The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Noninvasive Detection of Clinically Occult Lymph-Node Metastases in Prostate Cancer
Open accessAbstract
BACKGROUND: Accurate detection of lymph-node metastases in prostate cancer is an essential component of the approach to treatment. We investigated whether highly lymphotropic superparamagnetic nanoparticles, which gain access to lymph nodes by means of interstitial-lymphatic fluid transport, could be used in conjunction with high-resolution magnetic resonance imaging (MRI) to reveal small nodal metastases. METHODS: Eighty patients with presurgical clinical stage T1, T2, or T3 prostate cancer who underwent surgical lymph-node resection or biopsy were enrolled. All patients were examined by MRI before and 24 hours after the intravenous administration of lymphotropic superparamagnetic nanoparticles (2.6 mg of iron per kilogram of body weight). The imaging results were correlated with histopathological findings. RESULTS: Of the 334 lymph nodes that underwent resection or biopsy, 63 (18.9 percent) from 33 patients (41 percent) had histopathologically detected metastases. Of these 63 nodes, 45 (71.4 percent) did not fulfill the usual imaging criteria for malignancy. MRI with lymphotropic superparamagnetic nanoparticles correctly identified all patients with nodal metastases, and a node-by-node analysis had a significantly higher sensitivity than conventional MRI (90.5 percent vs. 35.4 percent, P<0.001) or nomograms. CONCLUSIONS: High-resolution MRI with magnetic nanoparticles allows the detection of small and otherwise undetectable lymph-node metastases in patients with prostate cancer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Significantly higher sensitivity for lymph node characterization in patients with prostate cancer, in which metastases detection with positron emission tomography (PET) is problematic, could be achieved by using ferumoxtran compared to non-contrast-enhanced MR imaging [160, 161].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [161]
In the citing paper
“Significantly higher sensitivity for lymph node characterization in patients with prostate cancer, in which metastases detection with positron emission tomography (PET) is problematic, could be achieved by using ferumoxtran compared to non-contrast-enhanced MR imaging [160, 161].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [160]
In the citing paper
“By using USPIO and contrast-enhanced MRI, micro-metastatic lymph nodes can be distinguished much more efficiently from healthy and inflammatory nodes [161].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [161]
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Stary, H. C., Chandler, A. B., Dinsmore, R. E., Fuster, V., Glagov, S. K., Insull, W., Rosenfeld, M. E., Schwartz, C. J., Wagner, W. D., & Wissler, R. W. (1995) · Circulation · doi:10.1161/01.cir.92.5.1355 · Cited by 3,506
Greenlee, R. T., Hill-Harmon, M. B., Murray, T., & Thun, M. J. (2001) · CA A Cancer Journal for Clinicians · doi:10.3322/canjclin.51.1.15 · Cited by 3,281
Lewin, M., Carlesso, N., Tung, C., Tang, X. S., Cory, D. G., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Self-citationROC Methodology in Radiologic Imaging
Metz, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,628
Bolla, M., González, D., Warde, P. R., Dubois, J. B., Mirimanoff, R., Storme, G. A., Bernier, J., Kuten, A., Sternberg, C. N., Gil, T., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199707313370502 · Cited by 1,547
Messing, E. M., Manola, J. B., Sarosdy, M., Wilding, G., Crawford, E. D., & Trump, D. L. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912093412401 · Cited by 1,178
Magnetic relaxation switches capable of sensing molecular interactions
Pérez, J. M. S., Josephson, L., O'Loughlin, T., Högemann, D., & Weissleder, R. (2002) · Nature Biotechnology · doi:10.1038/nbt720 · Cited by 889
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,499
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Nanomaterials and nanoparticles: Sources and toxicity
Buzea, C., Pacheco, I. I., & Robbie, K. (2007) · Biointerphases · doi:10.1116/1.2815690 · Cited by 3,789
Bertrand, N., Wu, J., Xu, X., Kamaly, N., & Farokhzad, O. C. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.009 · Cited by 2,925
Magnetic nanoparticles in MR imaging and drug delivery
Sun, C., Lee, J. S. H., & Zhang, M. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.018 · Cited by 2,642
Metadata
- Authors
- Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R.
- Affiliations
- Harvard University (US)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2003-06-19
- Volume
- 348
- Issue
- 25
- Pages
- 2491-2499
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2116810900
- Cited by
- 1,971
- References
- 42
- Citations by year
- 2026: 13 · 2025: 15 · 2024: 34 · 2023: 42 · 2022: 54 · 2021: 49 · 2020: 59 · 2019: 50 · 2018: 66 · 2017: 82 · 2016: 83 · 2015: 94 · 2014: 95 · 2013: 120 · 2012: 129
- FWCI
- 81.09
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- Funders
- National Institutes of Health (5r01ca059649-07)
- National Cancer Institute (R01-CA59649)
- Topics
- Health Sciences › Medicine › Urology › Prostate Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- prostate cancer, lymph node metastasis, superparamagnetic iron oxide nanoparticles, magnetic resonance imaging, non-invasive detection, lymphatic drainage, diagnostic sensitivity
- MeSH terms
- Aged, Biopsy, Contrast Media, Ferric Compounds, Humans, Image Processing, Computer-Assisted, Lymph Nodes, Lymphatic Metastasis, Magnetic Resonance Imaging, Magnetics, Male, Middle Aged, Neoplasm Staging, Particle Size, Prospective Studies, Prostatic Neoplasms, Sensitivity and Specificity, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review