Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 846

The DOI matches its Crossref record.

Acquired von Willebrand Syndrome in Aortic Stenosis

Open access
Vincentelli, André, Susen, Sophie, Le Tourneau, Thierry, Six, Isabelle, Fabre, Olivier, Juthier, Francis, Bauters, Anne, Decoene, Christophe, Goudemand, Jenny, Prat, Alain, Jude, Brigitte·2003·New England Journal of Medicine

Abstract

BACKGROUND: Aortic-valve stenosis can be complicated by bleeding that is associated with acquired type 2A von Willebrand syndrome. However, the prevalence and cause of the hemostatic abnormality in aortic stenosis are unknown. METHODS: We enrolled 50 consecutive patients with aortic stenosis, who completed a standardized screening questionnaire to detect a history of bleeding. Forty-two patients with severe aortic stenosis underwent valve replacement. Platelet function under conditions of high shear stress, von Willebrand factor collagen-binding activity and antigen levels, and the multimeric structure of von Willebrand factor were assessed at base line and one day, seven days, and six months postoperatively. RESULTS: Skin or mucosal bleeding occurred in 21 percent of the patients with severe aortic stenosis. Platelet-function abnormalities under conditions of high shear stress, decreased von Willebrand factor collagen-binding activity and the loss of the largest multimers, or a combination of these was present in 67 to 92 percent of patients with severe aortic stenosis and correlated significantly with the severity of valve stenosis. Primary hemostatic abnormalities were completely corrected on the first day after surgery but tended to recur at six months, especially when there was a mismatch between patient and prosthesis (with an effective orifice area of less than 0.8 cm2 per square meter of body-surface area). CONCLUSIONS: Type 2A von Willebrand syndrome is common in patients with severe aortic stenosis. Von Willebrand factor abnormalities are directly related to the severity of aortic stenosis and are improved by valve replacement in the absence of mismatch between patient and prosthesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa022831

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 846

Metadata

Authors
Vincentelli, A., Susen, S., Le Tourneau, T., Six, I., Fabre, O., Juthier, F., Bauters, A., Decoene, C., Goudemand, J., Prat, A., & Jude, B.
Venue
New England Journal of Medicine
Published
2003-07-24
Volume
349
Issue
4
Pages
343-349
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W1999680744
Cited by
846
References
0
FWCI
9.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acquired von Willebrand Syndrome in Aortic Stenosis. https://app.cochat.ai/papers/10.1056/nejmoa022831
The paper
Vincentelli, A., Susen, S., Le Tourneau, T., Six, I., Fabre, O., Juthier, F., Bauters, A., Decoene, C., Goudemand, J., Prat, A., & Jude, B. (2003). Acquired von Willebrand Syndrome in Aortic Stenosis. New England Journal of Medicine. https://doi.org/10.1056/nejmoa022831

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.