The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
A Quantitative Comparison of Mechanical Blood Damage Parameters in Rotary Ventricular Assist Devices: Shear Stress, Exposure Time and Hemolysis Index
Open accessAbstract
Ventricular assist devices (VADs) have already helped many patients with heart failure but have the potential to assist more patients if current problems with blood damage (hemolysis, platelet activation, thrombosis and emboli, and destruction of the von Willebrand factor (vWf)) can be eliminated. A step towards this goal is better understanding of the relationships between shear stress, exposure time, and blood damage and, from there, the development of numerical models for the different types of blood damage to enable the design of improved VADs. In this study, computational fluid dynamics (CFD) was used to calculate the hemodynamics in three clinical VADs and two investigational VADs and the shear stress, residence time, and hemolysis were investigated. A new scalar transport model for hemolysis was developed. The results were compared with in vitro measurements of the pressure head in each VAD and the hemolysis index in two VADs. A comparative analysis of the blood damage related fluid dynamic parameters and hemolysis index was performed among the VADs. Compared to the centrifugal VADs, the axial VADs had: higher mean scalar shear stress (sss); a wider range of sss, with larger maxima and larger percentage volumes at both low and high sss; and longer residence times at very high sss. The hemolysis predictions were in agreement with the experiments and showed that the axial VADs had a higher hemolysis index. The increased hemolysis in axial VADs compared to centrifugal VADs is a direct result of their higher shear stresses and longer residence times. Since platelet activation and destruction of the vWf also require high shear stresses, the flow conditions inside axial VADs are likely to result in more of these types of blood damage compared with centrifugal VADs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-equation eddy-viscosity turbulence models for engineering applications
Menter, F. R. (1994) · AIAA Journal · doi:10.2514/3.12149 · Cited by 21,593
Heart Disease and Stroke Statistics—2010 Update: A Report From the American Heart Association
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R. J., Brown, T. M., Carnethon, M., Dai, S., De Simone, G., Ferguson, T. B., Ford, E., Furie, K., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192667 · Cited by 5,700
QUANTIFICATION OF UNCERTAINTY IN COMPUTATIONAL FLUID DYNAMICS
Roache, P. J. (1997) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.29.1.123 · Cited by 2,319
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-499_7 · Cited by 1,564
THE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
Acquired von Willebrand Syndrome in Aortic Stenosis
Vincentelli, A., Susen, S., Le Tourneau, T., Six, I., Fabre, O., Juthier, F., Bauters, A., Decoene, C., Goudemand, J., Prat, A., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022831 · Cited by 846
Red Blood Cell Damage by Shear Stress
Leverett, L. B., Hellums, J. D., Alfrey, C. P., & Lynch, E. C. (1972) · Biophysical Journal · doi:10.1016/s0006-3495(72)86085-5 · Cited by 682
Giersiepen, M., Wurzinger, L. J., Opitz, R., & Reul, H. (1990) · The International Journal of Artificial Organs · doi:10.1177/039139889001300507 · Cited by 594
Cell Adhesion Mechanisms in Platelets
Varga-Szabo, D., Pleines, I., & Nieswandt, B. (2008) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.150474 · Cited by 588
Shear stress enhances the proteolysis of von Willebrand factor in normal plasma
Tsai, H., Sussman, II, & Nagel, R. (1994) · Blood · doi:10.1182/blood.v83.8.2171.2171 · Cited by 422
Metadata
- Authors
- Fraser, K. H., Zhang, T., Taskin, M. E., Griffith, B. P., & Wu, Z. J.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2012-08-01
- Volume
- 134
- Issue
- 8
- Pages
- 081002-081002
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2067626478
- Cited by
- 384
- References
- 26
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Quantitative Comparison of Mechanical Blood Damage Parameters in Rotary Ventricular Assist Devices: Shear Stress, Exposure Time and Hemolysis Index. https://app.cochat.ai/papers/10.1115/1.4007092
- The paper
- Fraser, K. H., Zhang, T., Taskin, M. E., Griffith, B. P., & Wu, Z. J. (2012). A Quantitative Comparison of Mechanical Blood Damage Parameters in Rotary Ventricular Assist Devices: Shear Stress, Exposure Time and Hemolysis Index. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4007092
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.