The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Open accessAbstract
BACKGROUND: Sudden death from cardiac causes remains a leading cause of death among patients with congestive heart failure (CHF). Treatment with amiodarone or an implantable cardioverter-defibrillator (ICD) has been proposed to improve the prognosis in such patients. METHODS: We randomly assigned 2521 patients with New York Heart Association (NYHA) class II or III CHF and a left ventricular ejection fraction (LVEF) of 35 percent or less to conventional therapy for CHF plus placebo (847 patients), conventional therapy plus amiodarone (845 patients), or conventional therapy plus a conservatively programmed, shock-only, single-lead ICD (829 patients). Placebo and amiodarone were administered in a double-blind fashion. The primary end point was death from any cause. RESULTS: The median LVEF in patients was 25 percent; 70 percent were in NYHA class II, and 30 percent were in class III CHF. The cause of CHF was ischemic in 52 percent and nonischemic in 48 percent. The median follow-up was 45.5 months. There were 244 deaths (29 percent) in the placebo group, 240 (28 percent) in the amiodarone group, and 182 (22 percent) in the ICD group. As compared with placebo, amiodarone was associated with a similar risk of death (hazard ratio, 1.06; 97.5 percent confidence interval, 0.86 to 1.30; P=0.53) and ICD therapy was associated with a decreased risk of death of 23 percent (0.77; 97.5 percent confidence interval, 0.62 to 0.96; P=0.007) and an absolute decrease in mortality of 7.2 percentage points after five years in the overall population. Results did not vary according to either ischemic or nonischemic causes of CHF, but they did vary according to the NYHA class. CONCLUSIONS: In patients with NYHA class II or III CHF and LVEF of 35 percent or less, amiodarone has no favorable effect on survival, whereas single-lead, shock-only ICD therapy reduces overall mortality by 23 percent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In studies, from 7.5% of primary prevention patients 22 to 48% of those with a history of ventricular arrhythmia 23 received a shock for any reason in a year.”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [22]
In the citing paper
“ICD treatment led to a significant relative risk reduction in death and in subgroup analysis, there were no interactions with T2DM.”
From Type 2 diabetes mellitus and heart failure: A position statement from the Heart Failure Association of the European Society of Cardiology (2018) · cites this paper as [165]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer series in statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,239
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
The Statistical Analysis of Failure Time Data.
Aitkin, M. A., Kalbfleisch, J. D., & Prentice, R. L. (1981) · Biometrics · doi:10.2307/2530581 · Cited by 9,875
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
The AVID Investigators (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,221
The Statistical Analysis of Failure Time Data
Kalbfleisch, J. D., & Prentice, R. L. (2002) · Wiley Series in Probability and Statistics · doi:10.1002/9781118032985 · Cited by 3,219
Discrete sequential boundaries for clinical trials
GORDON LAN, K. K., & DEMETS, D. L. (1983) · Biometrika · doi:10.1093/biomet/70.3.659 · Cited by 2,310
Flagged first, then by citations
Research works printed but not linked: 1
- 10.2307/2281868 · DOI · Paper page
Cited by
Sorted by citations
Items 601–700 of 1,019
Sohail, M. R., Eby, E. L., Ryan, M. P., Gunnarsson, C., Wright, L. A., & Greenspon, A. J. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.116.003929 · Cited by 101
Haines, D. E., Wang, Y., & Curtis, J. P. (2011) · Circulation · doi:10.1161/circulationaha.110.959676 · Cited by 100
DeSimone, C. V., Friedman, P. A., Noheria, A., Patel, N. A., DeSimone, D. C., Bdeir, S., Aakre, C. A., Vaidya, V. R., Slusser, J. P., Hodge, D. O., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.003540 · Cited by 100
Withdrawing Implantable Defibrillator Shock Therapy in Terminally Ill Patients
Lewis, W. R., Luebke, D. L., Johnson, N. J., Harrington, M., Costantini, O., & Aulisio, M. P. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2006.01.017 · Cited by 100
Amiodarone for the treatment and prevention of ventricular fibrillation and ventricular tachycardia
Dorian (2010) · Vascular Health and Risk Management · doi:10.2147/vhrm.s6611 · Cited by 101
Shun-Shin, M. J., Zheng, S. L., Cole, G. D., Howard, J. P., Whinnett, Z. I., & Francis, D. P. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx028 · Cited by 100
Al‐Khatib, S. M., Fonarow, G. C., Joglar, J. A., Inoue, L. Y. T., Mark, D. B., Lee, K. L., Kadish, A. H., Bardy, G. H., & Sanders, G. D. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.0630 · Cited by 100
Self-citationNielsen, J. C., Lin, Y., Figueiredo, M. J. D. O., Shamloo, A. S., Alfie, A., Bovéda, S., Dagres, N., Toro, D. D., Eckhardt, L. L., Ellenbogen, K. A., et al. (2020) · Journal of Arrhythmia · doi:10.1002/joa3.12338 · Cited by 106
Danik, S. B., MANSOUR, M. C., Singh, J. P., Reddy, V. Y., Ellinor, P. T., Milan, D. J., Heist, E. K., d’Ávila, A., Ruskin, J. N., & Mela, T. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.044 · Cited by 100
Gold, M. R., Weiss, R., Theuns, D. A. M. J., Smith, W., León, A. R., Knight, B. P., Carter, N., Husby, M. P., & Burke, M. C. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.04.012 · Cited by 99
Survival After Implantable Cardioverter-Defibrillator Implantation in the Elderly
Yung, D., BIRNIE, D. H., Dorian, P., Healey, J. S., Simpson, C. S., Crystal, E., Krahn, A. D., Khaykin, Y., CAMERON, D. A., Chen, Z., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.001442 · Cited by 99
Knops, R. E., Pepplinkhuizen, S., Delnoy, P. P. H. M., Boersma, L. V. A., Kuschyk, J., El‐Chami, M. F., Bonnemeier, H., Behr, E. R., Brouwer, T. F., Kääb, S., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac496 · Cited by 99
Randles, D. A., Hawkins, N. M., Shaw, M., Patwala, A., Pettit, S., & Wright, D. J. (2013) · EP Europace · doi:10.1093/europace/eut370 · Cited by 98
Anker, S. D., Schroeder, S., Atar, D., Bax, J. J., Ceconi, C., Cowie, M., Crisp, A., Dominjon, F., Ford, I., Ghofrani, H. A., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.516 · Cited by 108
Galand, V., Flecher, E. M., Auffret, V., Boulé, S., Vincentelli, A., Dambrin, C., Mondoly, P., Sacher, F., Nubret, K., Kindo, M. J., et al. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.05.006 · Cited by 98
Outcomes of Implantable Cardioverter-Defibrillator Use in Patients With Comorbidities
Steinberg, B. A., Al‐Khatib, S. M., Edwards, R., Han, J., Bardy, G. H., Bigger, J. T., Buxton, A. E., Moss, A. J., Lee, K. L., Steinman, R. C., et al. (2014) · JACC Heart Failure · doi:10.1016/j.jchf.2014.06.007 · Cited by 98
Self-citationNielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
Al‐Khatib, S. M., Hellkamp, A. S., Bardy, G. H., Hammill, S. C., Hall, W. J., Mark, D. B., Anstrom, K. J., Curtis, J. P., Al‐Khalidi, H. R., Curtis, L. H., et al. (2013) · JAMA · doi:10.1001/jama.2012.157182 · Cited by 97
Self-citationAuricchio, A., Metra, M., Gasparini, M., Lamp, B., Klersy, C., Curnis, A., Fantoni, C., Gronda, E., & Vogt, J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.07.087 · Cited by 97
Sudden cardiac death after myocardial infarction in patients with type 2 diabetes
Junttila, J. M., Barthel, P., Myerburg, R. J., Mäkikallio, T. H., Bauer, A., Ulm, K., Kiviniemi, A. M., Tulppo, M. P., Perkiömäki, J. S., Schmidt, G. P., et al. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.07.031 · Cited by 98
Kramer, D. B., Friedman, P. A., Kallinen, L. M., Morrison, T. B., Crusan, D. J., Hodge, D. O., Reynolds, M. R., & Hauser, R. G. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.08.031 · Cited by 94
Bennett, M. T., Parkash, R., Nery, P. B., Sénéchal, M., Mondesert, B. A., BIRNIE, D. H., Sterns, L. D., Rinne, C., Exner, D. V., Philippon, F., et al. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.09.009 · Cited by 102
Catheter Ablation of Ventricular Tachycardia in Structural Heart Disease
Dukkipati, S. R., Koruth, J. S., Choudry, S., Miller, M. A., Whang, W., & Reddy, V. Y. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.030 · Cited by 103
Vergara, P., Tzou, W. S., Tung, R. H., Brombin, C., Nonis, A., Vaseghi, M., Frankel, D. S., Biase, L. D., Tedrow, U. B., Mathuria, N. S., et al. (2018) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006730 · Cited by 99
Merino, J. L., Tamargo, J. L., Blomström‐Lundqvist, C., Boriani, G., Crijns, H. J. G. M., Dobrev, D., Goette, A., Hohnloser, S. H., Naccarelli, G. V., Reiffel, J. A., et al. (2025) · EP Europace · doi:10.1093/europace/euaf076 · Cited by 112
Anderson, K. P. (2005) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-005-4547-9 · Cited by 96
Vijgen, J. M., Botto, G., Camm, J. A., Höijer, C. J., Jung, W., Heuzey, J. L., Lubiński, A., Norekvål, T. M., Santomauro, M., Schalij, M. J., et al. (2009) · EP Europace · doi:10.1093/europace/eup112 · Cited by 94
Leitlinien zur Implantation von Defibrillatoren
Hohnloser, S. H., Andresen, D., Block, M. S., Breithardt, G., Jung, W., Klein, H. H., Kuck, K. H., Lüderitz, B., & Steinbeck, G. (2001) · Steinkopff eBooks · doi:10.1007/978-3-642-57631-7_8 · Cited by 96
What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up?
Brugada, P. (2006) · Clinical Research in Cardiology · doi:10.1007/s00392-006-1302-x · Cited by 94
The ICD for Primary Prevention in Patients With Inherited Cardiac Diseases
Nordkamp, L. R. A. O., Wilde, A. A. M., Tijssen, J. G. P., Knops, R. E., van Dessel, P. F. H. M., & de Groot, J. R. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.112.975268 · Cited by 94
Leitlinien zur Implantation von Defibrillatoren
Jung, W., Andresen, D., Block, M. S., Böcker, D., Hohnloser, S. H., Kück, K., & Sperzel, J. (2006) · Clinical Research in Cardiology · doi:10.1007/s00392-006-0475-7 · Cited by 95
Implantable Cardiac Device Procedures in Older Patients
Swindle, J. P., Rich, M. W., McCann, P., Burroughs, T. E., & Hauptman, P. J. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.30 · Cited by 96
Amiodarone-Induced Thyrotoxicosis Is a Predictor of Adverse Cardiovascular Outcome
Yiu, K., Jim, M., Siu, C., Lee, C., Yuen, M. M. A., Mok, M. M. Y., Shea, Y.-F., Fan, K., Tse, H., & Chow, W. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-1907 · Cited by 96
Risk stratification in surgically repaired tetralogy of Fallot
Khairy, P., Dore, A., Poirier, N. C., Marcotte, F., Ibrahim, R., Mongeon, F., & Mercier, L. (2009) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.09.38 · Cited by 95
Pueschner, A., Chattranukulchai, P., Heitner, J. F., Shah, D. J., Hayes, B. D., Rehwald, W. G., Parker, M. A., Kim, H. W., Judd, R. M., Kim, R. J., et al. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2017.06.013 · Cited by 95
Use of Cardiac Resynchronization Therapy in Patients Hospitalized With Heart Failure
Piccini, J. P., Hernandez, A. F., Dai, D., Thomas, K. L., Lewis, W. R., Yancy, C. W., Peterson, E. D., & Fonarow, G. C. (2008) · Circulation · doi:10.1161/circulationaha.108.773838 · Cited by 94
Narayanan, K., Reinier, K., Uy‐Evanado, A., Teodorescu, C., Chugh, H. S., Marijon, É., Gunson, K., Jui, J., & Chugh, S. S. (2013) · Circulation · doi:10.1161/circulationaha.113.002539 · Cited by 94
Respiratory rate predicts outcome after acute myocardial infarction: a prospective cohort study
Barthel, P., Wensel, R., Bauer, A., Muller, A., Wolf, P., Ulm, K., Huster, K. M., Francis, D. P., Malik, M., & Schmidt, G. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs420 · Cited by 94
Patient Perceptions, Physician Communication, and the Implantable Cardioverter-Defibrillator
Hauptman, P. J., Chibnall, J. T., Guild, C., & Armbrecht, E. S. (2013) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2013.3171 · Cited by 94
Lip, G. Y. H., Heinzel, F. R., Gaïta, F., González‐Juanatey, J. R., Heuzey, J. Y. L., Potpara, T., Svendsen, J. H., Vos, M. A., Anker, S. D., Coats, A. J. S., et al. (2015) · EP Europace · doi:10.1093/europace/euv191 · Cited by 99
The fractal heart — embracing mathematics in the cardiology clinic
Captur, G., Karperien, A., Hughes, A. D., Francis, D. P., & Moon, J. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.161 · Cited by 94
Chan, P. S., Nallamothu, B. K., Spertus, J. A., Masoudi, F. A., Bartone, C. L., Kereiakes, D. J., & Chow, T. (2009) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.108.807123 · Cited by 94
Al‐Khatib, S. M., Daubert, J. P., Anstrom, K. J., Daoud, E. G., Gonzalez, M. D., Saba, S., JACKSON, K. P., Reece, T. L., Gu, J., Pokorney, S. D., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12567 · Cited by 93
Self-citationLong-Term Outcomes of Implantable Cardioverter-Defibrillator Therapy in the SCD-HeFT
Poole, J. E., Olshansky, B., Mark, D. B., Anderson, J., Johnson, G. W., Hellkamp, A. S., Davidson-Ray, L. D., Fishbein, D. P., Boineau, R., Anstrom, K. J., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.05.061 · Cited by 91
Self-citationGreenspon, A. J., Prutkin, J. M., Sohail, M. R., Vikram, H. R., Baddour, L. M., Danik, S. B., Peacock, J. E., Falces, C., Miró, J. M., Blank, E., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.011 · Cited by 92
Early identification of risk factors for sudden cardiac death
Chugh, S. S. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.52 · Cited by 95
Nolan, J. P., Neumar, R. W., Adrie, C., Aibiki, M., Berg, R. A., Bbttiger, B. W., Callaway, C. W., Clark, R. S. B., Geocadin, R. G., Jauch, E. C., et al. (2009) · International Emergency Nursing · doi:10.1016/j.ienj.2009.01.001 · Cited by 93
Goldberger, J. J., CAIN, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., PASSMAN, R. S., Siscovick, D. S., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.05.031 · Cited by 93
Wißner, E., Stevenson, W. G., & Kück, K. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs007 · Cited by 94
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al‐Khatib, S. M., Anter, E., et al. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00663-3 · Cited by 95
Guidelines for Secondary Prevention of Myocardial Infarction (JCS 2011)
JCS Joint Working Group (2012) · Circulation Journal · doi:10.1253/circj.cj-66-0053 · Cited by 92
Effective Management of ICD Patient Psychosocial Issues and Patient Critical Events
Sears, S. F., Matchett, M., & CONTI, J. B. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01526.x · Cited by 92
Cannesson, M. P., Tanabe, M., Suffoletto, M. S., McNamara, D. M., Madan, S., Lacomis, J. M., & Gorcsan, J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.045 · Cited by 93
Zhang, Y., Güallar, E., Blasco‐Colmenares, E., Butcher, B., Norgard, S., Nauffal, V. D., Marine, J. E., ELDADAH, Z. A., Dickfeld, T. M., Ellenbogen, K. A., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.05.057 · Cited by 91
Rhythm Control in Heart Failure Patients With Atrial Fibrillation
Trulock, K. M., Narayan, S. M., & Piccini, J. P. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.06.1169 · Cited by 92
Meta-Analysis of Mortality in Dialysis Patients With an Implantable Cardioverter Defibrillator
Sakhuja, R., Keebler, M., Lai, T., McLaughlin-Gavin, C., Thakur, R. K., & Bhatt, D. L. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.11.014 · Cited by 90
Nonadherence to treatment protocol in published randomised controlled trials: a review
Dodd, S. R., White, I. R., & Williamson, P. R. (2012) · Trials · doi:10.1186/1745-6215-13-84 · Cited by 89
Refaat, M. M., Tanaka, T. D., Kormos, R. L., McNamara, D. M., Teuteberg, J. J., Winowich, S., London, B., & Simon, M. A. M. (2011) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2011.10.020 · Cited by 91
A genetic framework for improving arrhythmia therapy
Knollmann, B. C., & Roden, D. M. (2008) · Nature · doi:10.1038/nature06799 · Cited by 89
Hammill, S. C., Kremers, M. S., Kadish, A. H., Stevenson, L. W., Heidenreich, P. A., Lindsay, B. D., Mirro, M. J., Radford, M. J., McKay, C., Wang, Y., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.07.015 · Cited by 91
Pharmacokinetics of Amiodarone in hyperlipidemic and simulated high fat‐meal rat models
Shayeganpour, A., Jun, A. S., & Brocks, D. R. (2005) · Biopharmaceutics & Drug Disposition · doi:10.1002/bdd.457 · Cited by 91
Francis, G. S., Greenberg, B., Hsu, D. T., Jaski, B. E., Jessup, M. L., LeWinter, M. M., Pagani, F. D., Piña, I. L., Semigran, M. J., Walsh, M. N., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.014 · Cited by 91
Matching the Market for Heart Transplantation
Hsich, E. (2016) · Circulation Heart Failure · doi:10.1161/circheartfailure.115.002679 · Cited by 91
Beggs, S. A. S., Jhund, P. S., Jackson, C. E., McMurray, J. J. V., & Gardner, R. S. (2017) · Heart · doi:10.1136/heartjnl-2016-310850 · Cited by 90
Sudden Death in Patients With Cardiac Implantable Electronic Devices
Tseng, Z. H., Hayward, R. M., Clark, N. M., Mulvanny, C. G., Colburn, B., Ursell, P. C., Olgin, J. E., Hart, A. P., & Moffatt, E. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.2641 · Cited by 92
Amiodarone: an effective antiarrhythmic drug with unusual side effects
ERVEN, L. V., & Schalij, M. J. (2010) · Heart · doi:10.1136/hrt.2008.152652 · Cited by 91
Howlett, J. G., McKelvie, R. S., Arnold, J. M. O., Costigan, J., Dorian, P., Ducharme, A., Estrella-Holder, E., Ezekowitz, J. A., Giannetti, N., Haddad, H. A., et al. (2009) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(09)70477-5 · Cited by 90
Bhakta, D., Groh, M. R., Shen, C., Pascuzzi, R. M., & Groh, W. J. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.07.032 · Cited by 89
Cardiac Applications of 123I-mIBG Imaging
Chirumamilla, A. P., & Travin, M. I. (2011) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.04.001 · Cited by 89
Increased Left Ventricular Mass as a Predictor of Sudden Cardiac Death
Stevens, S. M., Reinier, K., & Chugh, S. S. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.112.974931 · Cited by 89
Maron, B. J., Rowin, E. J., & Maron, M. S. (2021) · Heart Rhythm · doi:10.1016/j.hrthm.2021.01.019 · Cited by 89
Friedman, P. A., MURGATROYD, F. D., Boersma, L. V. A., Manlucu, J., Knight, B. P., Clémenty, N., Leclercq, C., Amin, A. K., Merkely, B. P., Birgersdotter-Green, U. M., et al. (2024) · Circulation · doi:10.1161/circulationaha.124.071795 · Cited by 89
Evidence regarding clinical use of microvolt T-wave alternans
Hohnloser, S. H., Ikeda, T., & Cohen, R. J. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.011 · Cited by 89
Mitochondrial dysfunction causing cardiac sodium channel downregulation in cardiomyopathy
Liu, M., Gu, L., Sulkin, M. S., Liu, H., Jeong, E.-M., Greener, I. D., Xie, A., Efimov, I. R., & Dudley, S. C. (2012) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2012.10.011 · Cited by 90
Advances in Echocardiographic Imaging in Heart Failure With Reduced and Preserved Ejection Fraction
Omar, A. M. S., Bansal, M., & Sengupta, P. P. (2016) · Circulation Research · doi:10.1161/circresaha.116.309128 · Cited by 91
Saklani, P., Krahn, A. D., & Klein, G. J. (2013) · Circulation · doi:10.1161/circulationaha.112.138396 · Cited by 91
Pavri, B. B., Hillis, M. B., Subačius, H., Brumberg, G. E., Schaechter, A., Levine, J. H., & Kadish, A. (2008) · Circulation · doi:10.1161/circulationaha.107.733451 · Cited by 88
2020 Clinical practice guidelines for Chronic heart failure
Russian Society of Cardiology (2020) · Russian Journal of Cardiology · doi:10.15829/29/1560-4071-2020-4083 · Cited by 88
Frankel, D. S., Mountantonakis, S., Robinson, M., Zado, E. S., Callans, D. J., & Marchlinski, F. E. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02081.x · Cited by 88
The diagnosis and management of ventricular arrhythmias
Roberts‐Thomson, K. C., Lau, D. H., & Sanders, P. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.15 · Cited by 91
Implantable Defibrillators and Prevention of Sudden Death in Hypertrophic Cardiomyopathy
Maron, B. J., & Spirito, P. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01147.x · Cited by 89
Narayanan, K., Reinier, K., Teodorescu, C., Uy‐Evanado, A., Chugh, H. S., Gunson, K., Jui, J., & Chugh, S. S. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.03.023 · Cited by 88
Heywood, J. T., Fonarow, G. C., Yancy, C. W., Albert, N. M., Curtis, A. B., Gheorghiade, M., Inge, P. J., McBride, M. L., Mehra, M. R., O’Connor, C. M., et al. (2010) · Circulation Heart Failure · doi:10.1161/circheartfailure.109.912683 · Cited by 88
Nolan, J. P., Neumar, R. W., Adrie, C., Aibiki, M., Berg, R. A., Bbttiger, B. W., Callaway, C. W., Clark, R. S. B., Geocadin, R. G., Jauch, E. C., et al. (2009) · International Emergency Nursing · doi:10.1016/j.ienj.2009.07.001 · Cited by 90
Matlock, D. D., Nowels, C. T., Masoudi, F. A., Sauer, W. H., Bekelman, D. B., Main, D. S., & Kutner, J. S. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03237.x · Cited by 87
Sudden Cardiac Death: Epidemiology, Mechanisms, and Therapy
Turakhia, M. P., & Tseng, Z. H. (2007) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2007.05.002 · Cited by 88
Cost-effectiveness of heart failure therapies
Rohde, L. E. P., Bertoldi, E. G., Goldraich, L. A., & Polanczyk, C. A. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.60 · Cited by 86
Gulizia, M. M., Piraino, L., Scherillo, M., Puntrello, C., Vasco, C., Scianaro, M. C., Mascia, F., Pensabene, O., Giglia, S., Chiarandà, G., et al. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.804211 · Cited by 87
Russo, A. M., Daugherty, S. L., Masoudi, F. A., Wang, Y., Curtis, J. P., & Lampert, R. J. (2015) · American Heart Journal · doi:10.1016/j.ahj.2015.02.025 · Cited by 86
Mandawat, A., Chattranukulchai, P., Mandawat, A., Blood, A. J., Ambati, S., Hayes, B. D., Rehwald, W. G., Kim, H. W., Heitner, J. F., Shah, D. J., et al. (2021) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2020.11.006 · Cited by 86
Teodorescu, C., Reinier, K., Uy‐Evanado, A., Navarro, J., Mariani, R., Gunson, K., Jui, J., & Chugh, S. S. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.06.011 · Cited by 86
Russo, A. M., Poole, J. E., Mark, D. B., Anderson, J., Hellkamp, A. S., Lee, K. L., Johnson, G. W., DOMANSKI, M. J., & Bardy, G. H. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01129.x · Cited by 86
Self-citationImplantable cardioverter-defibrillator deactivation at the end of life: A physician survey
Kelley, A. S., Reid, M. C., Miller, D. H., Fins, J. J., & Lachs, M. S. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.12.011 · Cited by 86
Implantable Cardioverter Defibrillator Therapy in Adults With Congenital Heart Disease
Koyak, Z., de Groot, J. R., Gelder, I. C. V., Bouma, B. J., van Dessel, P. F. H. M., Budts, W., van Erven, L., van Dijk, A. P. J., Wilde, A. A. M., Pieper, P. G., et al. (2011) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.966754 · Cited by 85
Theuns, D. A. M. J., Schaer, B. A., Soliman, O. I. I., Altmann, D., Sticherling, C., Geleijnse, M. L., Osswald, S., & Jordaens, L. J. L. M. (2010) · EP Europace · doi:10.1093/europace/euq328 · Cited by 86
Rosselló, X., Ariti, C. A., Pocock, S., Ferreira, J. P., Girerd, N., McMurray, J. J. V., van Veldhuisen, D. J., Pitt, B., & Zannad, F. M. (2018) · Clinical Research in Cardiology · doi:10.1007/s00392-018-1378-0 · Cited by 89
Amiodarone-Induced Thyrotoxicosis
Conen, D., Melly, L., Kaufmann, C. C., Bilz, S., Ammann, P., Schaer, B. A., Sticherling, C., Müller-Stich, B. P., & Osswald, S. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.054 · Cited by 87
Review of the Registry’s First Year, Data Collected, and Future Plans
Hammill, S. C., Stevenson, L. W., Kadish, A. H., Kremers, M. S., Heidenreich, P. A., Lindsay, B. D., Mirro, M. J., Radford, M. J., Wang, Y., Lang, C. M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.07.021 · Cited by 85
Reinier, K., Dervan, C., Singh, T., Uy‐Evanado, A., Lai, S., Gunson, K., Jui, J., & Chugh, S. S. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.02.037 · Cited by 84
Risk stratification of sudden cardiac death: a review
Tfelt‐Hansen, J., Garcia, R., Albert, C. M., Merino, J. L., Krahn, A. D., Marijon, É., Basso, C., Wilde, A. A. M., & Haugaa, K. H. (2023) · EP Europace · doi:10.1093/europace/euad203 · Cited by 84
Metadata
- Authors
- Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., McNulty, S. E., Clapp-Channing, N., Davidson-Ray, L. D., Fraulo, E. S., Fishbein, D. P., Luceri, R. M., & Ip, J. H.
- Affiliations
- The Seattle Institute for Cardiac Research (US)
- Duke University (US)
- University of Washington (US)
- Mayo Clinic (US)
- National Heart, Lung, and Blood Institute (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2005-01-20
- Volume
- 352
- Issue
- 3
- Pages
- 225-237
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2075175982
- Semantic Scholar
- cf04075b17dbae3fc6bc9a3a2f9673f9fad192ea
- Cited by
- 6,552
- References
- 20
- Citations by year
- 2026: 126 · 2025: 170 · 2024: 173 · 2023: 186 · 2022: 231 · 2021: 236 · 2020: 261 · 2019: 285 · 2018: 287 · 2017: 394 · 2016: 326 · 2015: 355 · 2014: 335 · 2013: 369 · 2012: 376
- FWCI
- 292.60
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (UO1 HL55297, UO1 HL55496, UO1 HL55766, U01HL055297, U01HL055766, U01HL055496)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- amiodarone, implantable cardioverter-defibrillator, congestive heart failure, sudden cardiac death, mortality, left ventricular ejection fraction, NYHA functional class, antiarrhythmic therapy
- MeSH terms
- Aged, Amiodarone, Anti-Arrhythmia Agents, Cause of Death, Female, Heart Failure, Humans, Male, Middle Aged, Risk, Stroke Volume, Survival Analysis, Death, Sudden, Cardiac, Defibrillators, Implantable, Cross-Over Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review