Plasma Exchange for Primary Autoimmune Autonomic Failure
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We report on a patient with long-standing severe autonomic failure that affected his sympathetic and parasympathetic nervous systems.Antibodies against the ganglionic acetylcholine receptors were detected in the serum.Removal of the antibodies by means of plasma exchange resulted in a dramatic clinical improvement.A 43-year-old man presented with recurrent orthostatic syncope.His symptoms had developed gradually over a 20-year period.Recently, he was unable to stand upright for more than a few seconds before fainting.He also reported decreased sweating, dry mouth, and urinary retention.He had difficulty focusing on near objects.Early satiety, summary " h case report
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Autoantibodies to ganglionic acetylcholine receptors in autoimmune autonomic neuropathies
Vernino, S., Low, P. A., Fealey, R. D., Stewart, J. D., Farrugia, G., & Lennon, V. A. (2000) · New England Journal of Medicine · doi:10.1056/nejm200009213431204 · Cited by 674
Immunization with neuronal nicotinic acetylcholine receptor induces neurological autoimmune disease
Lennon, V. A., Ermilov, L. G., Szurszewski, J. H., & Vernino, S. (2003) · Journal of Clinical Investigation · doi:10.1172/jci17429 · Cited by 178
Self-citationShannon, J. R., Jordan, J., Black, B. K., Costa, F., & Robertson, D. (1998) · Hypertension · doi:10.1161/01.hyp.32.1.101 · Cited by 65
Self-citation
Cited by
Connelly‐Smith, L., Alquist, C. R., Aqui, N. A., Hofmann, J. C., Klingel, R., Onwuemene, O. A., Patriquin, C. J., Pham, H. P., Sanchez, A. P., Schneiderman, J., et al. (2023) · Journal of Clinical Apheresis · doi:10.1002/jca.22043 · Cited by 684
Autonomic peripheral neuropathy
Freeman, R. (2005) · The Lancet · doi:10.1016/s0140-6736(05)74815-7 · Cited by 270
Autonomic ganglia, acetylcholine receptor antibodies, and autoimmune ganglionopathy
Vernino, S., Hopkins, S., & Wang, Z. (2009) · Autonomic Neuroscience · doi:10.1016/j.autneu.2008.09.005 · Cited by 123
Self-citationPostural Orthostatic Tachycardia Syndrome: Prevalence, Pathophysiology, and Management
Zadourian, A., Doherty, T. A., Swiatkiewicz, I., & Taub, P. R. (2018) · Drugs · doi:10.1007/s40265-018-0931-5 · Cited by 90
Wang, Z., Low, P. A., & Vernino, S. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2009.12.016 · Cited by 34
“In some cases, patients treated with plasma exchange or other immunomodulatory treatments to reduce antibody levels can show dramatic improvement in autonomic function (Gibbons et al., 2008; Schroeder et al., 2005).”
Self-citation
Metadata
- Authors
- Schroeder, C., Vernino, S., Birkenfeld, A. L., Tank, J., Heusser, K., Lipp, A., Benter, T., Lindschau, C., Kettritz, R., Luft, F. C., & Jordan, J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2005-10-13
- Volume
- 353
- Issue
- 15
- Pages
- 1585-1590
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2022585600
- Cited by
- 120
- References
- 3
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasma Exchange for Primary Autoimmune Autonomic Failure. https://app.cochat.ai/papers/10.1056/nejmoa051719
- The paper
- Schroeder, C., Vernino, S., Birkenfeld, A. L., Tank, J., Heusser, K., Lipp, A., Benter, T., Lindschau, C., Kettritz, R., Luft, F. C., & Jordan, J. (2005). Plasma Exchange for Primary Autoimmune Autonomic Failure. New England Journal of Medicine. https://doi.org/10.1056/nejmoa051719
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.