The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Paclitaxel-Eluting Stents versus Bare-Metal Stents in Acute Myocardial Infarction
Open accessAbstract
BACKGROUND: There is no consensus regarding the safety and efficacy of drug-eluting stents, as compared with bare-metal stents, in patients with ST-segment elevation myocardial infarction who are undergoing primary percutaneous coronary intervention (PCI). METHODS: We randomly assigned, in a 3:1 ratio, 3006 patients presenting with ST-segment elevation myocardial infarction to receive paclitaxel-eluting stents (2257 patients) or otherwise identical bare-metal stents (749 patients). The two primary end points of the study were the 12-month rates of target-lesion revascularization for ischemia (analysis powered for superiority) and a composite safety outcome measure of death, reinfarction, stroke, or stent thrombosis (powered for noninferiority with a 3.0% margin). The major secondary end point was angiographic evidence of restenosis at 13 months. RESULTS: Patients who received paclitaxel-eluting stents, as compared with those who received bare-metal stents, had significantly lower 12-month rates of ischemia-driven target-lesion revascularization (4.5% vs. 7.5%; hazard ratio, 0.59; 95% confidence interval [CI], 0.43 to 0.83; P=0.002) and target-vessel revascularization (5.8% vs. 8.7%; hazard ratio, 0.65; 95% CI, 0.48 to 0.89; P=0.006), with noninferior rates of the composite safety end point (8.1% vs. 8.0%; hazard ratio, 1.02; 95% CI, 0.76 to 1.36; absolute difference, 0.1 percentage point; 95% CI, -2.1 to 2.4; P=0.01 for noninferiority; P=0.92 for superiority). Patients treated with paclitaxel-eluting stents and those treated with bare-metal stents had similar 12-month rates of death (3.5% and 3.5%, respectively; P=0.98) and stent thrombosis (3.2% and 3.4%, respectively; P=0.77). The 13-month rate of binary restenosis was significantly lower with paclitaxel-eluting stents than with bare-metal stents (10.0% vs. 22.9%; hazard ratio, 0.44; 95% CI, 0.33 to 0.57; P<0.001). CONCLUSIONS: In patients with ST-segment elevation myocardial infarction who were undergoing primary PCI, implantation of paclitaxel-eluting stents, as compared with bare-metal stents, significantly reduced angiographic evidence of restenosis and recurrent ischemia necessitating repeat revascularization procedures. No safety concerns were apparent at 1 year. (ClinicalTrials.gov number, NCT00433966.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Self-citationMoses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Bivalirudin during Primary PCI in Acute Myocardial Infarction
Stone, G. W., Witzenbichler, B., Guagliumi, G., Peruga, J. Z., Brodie, B. R., Dudek, D., Kornowski, R., Hartmann, F., Gersh, B. J., Pocock, S. J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708191 · Cited by 1,867
Self-citationSafety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
Self-citationStent Thrombosis in Randomized Clinical Trials of Drug-Eluting Stents
Mauri, L., Hsieh, W.-H., Massaro, J. M., Ho, K. K. L., D'Agostino, R., & Cutlip, D. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067731 · Cited by 1,441
Comparison of Angioplasty with Stenting, with or without Abciximab, in Acute Myocardial Infarction
Stone, G. W., Grines, C. L., Cox, D. A., Garcia, E., Tcheng, J. E., Griffin, J. J., Guagliumi, G., Stuckey, T., Turco, M., Carroll, J. D., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013404 · Cited by 1,277
Self-citationNakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., Gold, H. K., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2008) · Circulation · doi:10.1161/circulationaha.107.762047 · Cited by 611
Stone, G. W. (2008) · JAMA · doi:10.1001/jama.299.16.1903 · Cited by 582
Self-citationClinical Outcomes and Stent Thrombosis Following Off-Label Use of Drug-Eluting Stents
Win, H. K., Caldera, A. E., Maresh, K., Lopez, J., Rihal, C. S., Parikh, M. A., Granada, J. F., Marulkar, S., Nassif, D., Cohen, D. J., et al. (2007) · JAMA · doi:10.1001/jama.297.18.2001 · Cited by 343
Urban, P., Gershlick, A. H., Guagliumi, G., Guyon, P., Lotan, C., Schofer, J., Seth, A., Sousa, J. E., Wijns, W., Berge, C., et al. (2006) · Circulation · doi:10.1161/circulationaha.104.532242 · Cited by 322
Self-citation
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Self-citationWriting Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
Self-citation2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention
Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.007 · Cited by 2,164
Self-citationKushner, F. G., Hand, M., Smith, S. C., King, S. B., Anderson, J. L., Antman, E. M., Bailey, S. R., Bates, E. R., Blankenship, J. C., Casey, D. E., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.015 · Cited by 1,911
Kushner, F. G., Hand, M., Smith, S. C., King, S. B., Anderson, J. L., Antman, E. M., Bailey, S. R., Bates, E. R., Blankenship, J. C., Casey, D. E., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.192663 · Cited by 1,700
Metadata
- Authors
- Stone, G. W., Lansky, A. J., Pocock, S. J., Gersh, B. J., Dangas, G., Wong, S. C., Witzenbichler, B., Guagliumi, G., Peruga, J. Z., Brodie, B. R., Dudek, D., Möckel, M., Ochala, A., Kellock, A., Parise, H., & Mehran, R.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2009-05-07
- Volume
- 360
- Issue
- 19
- Pages
- 1946-1959
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2101819411
- Cited by
- 443
- References
- 19
- FWCI
- 66.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Paclitaxel-Eluting Stents versus Bare-Metal Stents in Acute Myocardial Infarction. https://app.cochat.ai/papers/10.1056/nejmoa0810116
- The paper
- Stone, G. W., Lansky, A. J., Pocock, S. J., Gersh, B. J., Dangas, G., Wong, S. C., Witzenbichler, B., Guagliumi, G., Peruga, J. Z., Brodie, B. R., Dudek, D., Möckel, M., Ochala, A., Kellock, A., Parise, H., & Mehran, R. (2009). Paclitaxel-Eluting Stents versus Bare-Metal Stents in Acute Myocardial Infarction. New England Journal of Medicine. https://doi.org/10.1056/nejmoa0810116
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.