Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 322

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Safety of Coronary Sirolimus-Eluting Stents in Daily Clinical Practice: One-Year Follow-Up of the e-Cypher Registry

Urban, Philip, Gershlick, Anthony H., Guagliumi, Giulio, Guyon, Philippe, Lotan, Chaim, Schofer, Joachim, Seth, Ashok, Sousa, J. Eduardo, Wijns, William, Berge, Claude, Deme, Monika, Stoll, Hans-Peter·2006·Circulation

Abstract

Background— The expanding indications for sirolimus-eluting stents (SES) include increasingly complex coronary lesions and populations with clinical profiles markedly different from those of early pivotal controlled studies. The e-Cypher registry monitored the safety and efficacy of SES currently implanted worldwide in daily practice. Methods and Results— Between April 2002 and September 2005, data were collected on 15 157 patients who underwent implantation of ≥1 SES at 279 medical centers from 41 countries. An independent endpoint review committee adjudicated all reported major adverse cardiovascular events, stent thromboses, and target-vessel revascularizations. Data were managed and analyzed by independent organizations. Predictors of adverse clinical events were identified by regression analysis. The mean age of the sample was 61.7±11.4 years; 77.7% were men, and 28.6% were diabetics. A total of 18 295 lesions were treated (20 503 SES) during the index procedure. The cumulative rates of major adverse cardiovascular events were 1.36% at 30 days, 3.38% at 6 months, and 5.80% at 1 year. The rates of acute, subacute, and late stent thrombosis were 0.13%, 0.56%, and 0.19% of patients, respectively, representing a 12-month actuarial incidence of 0.87%. Insulin-dependent diabetes, acute coronary syndrome at presentation, and advanced age were clinical predictors, whereas TIMI flow grade <3 after the index procedure, treatment of multiple lesions, a prominently calcified or totally occluded target lesion, and multivessel disease were the angiographic or procedural predictors of stent thrombosis at 12 months. Conclusions— This analysis of 1-year data collected by the e-Cypher registry suggests a high degree of safety of SES, with a rate of stent thrombosis similar to that observed in randomized trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.532242

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 322

Metadata

Authors
Urban, P., Gershlick, A. H., Guagliumi, G., Guyon, P., Lotan, C., Schofer, J., Seth, A., Sousa, J. E., Wijns, W., Berge, C., Deme, M., & Stoll, H.-P.
Venue
Circulation
Published
2006-03-21
Volume
113
Issue
11
Pages
1434-1441
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2097373927
Cited by
322
References
22
FWCI
52.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety of Coronary Sirolimus-Eluting Stents in Daily Clinical Practice: One-Year Follow-Up of the e-Cypher Registry. https://app.cochat.ai/papers/10.1161/circulationaha.104.532242
The paper
Urban, P., Gershlick, A. H., Guagliumi, G., Guyon, P., Lotan, C., Schofer, J., Seth, A., Sousa, J. E., Wijns, W., Berge, C., Deme, M., & Stoll, H.-P. (2006). Safety of Coronary Sirolimus-Eluting Stents in Daily Clinical Practice: One-Year Follow-Up of the e-Cypher Registry. Circulation. https://doi.org/10.1161/circulationaha.104.532242

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.