Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,687

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays

Open access
Reichlin, Tobias, Hochholzer, Willibald, Bassetti, Stefano, Steuer, Stephan, Stelzig, Claudia, Hartwiger, Sabine, Biedert, Stefan, Schaub, Nora, Buerge, Christine, Potocki, Mihael, Noveanu, Markus, Breidthardt, Tobias, Twerenbold, Raphael, Winkler, Katrin, Bingisser, Roland, Mueller, Christian·2009·New England Journal of Medicine

Abstract

BACKGROUND: The rapid and reliable diagnosis of acute myocardial infarction is a major unmet clinical need. METHODS: We conducted a multicenter study to examine the diagnostic accuracy of new, sensitive cardiac troponin assays performed on blood samples obtained in the emergency department from 718 consecutive patients who presented with symptoms suggestive of acute myocardial infarction. Cardiac troponin levels were determined in a blinded fashion with the use of four sensitive assays (Abbott-Architect Troponin I, Roche High-Sensitive Troponin T, Roche Troponin I, and Siemens Troponin I Ultra) and a standard assay (Roche Troponin T). The final diagnosis was adjudicated by two independent cardiologists. RESULTS: Acute myocardial infarction was the adjudicated final diagnosis in 123 patients (17%). The diagnostic accuracy of measurements obtained at presentation, as quantified by the area under the receiver-operating-characteristic curve (AUC), was significantly higher with the four sensitive cardiac troponin assays than with the standard assay (AUC for Abbott-Architect Troponin I, 0.96; 95% confidence interval [CI], 0.94 to 0.98; for Roche High-Sensitive Troponin T, 0.96; 95% CI, 0.94 to 0.98; for Roche Troponin I, 0.95; 95% CI, 0.92 to 0.97; and for Siemens Troponin I Ultra, 0.96; 95% CI, 0.94 to 0.98; vs. AUC for the standard assay, 0.90; 95% CI, 0.86 to 0.94). Among patients who presented within 3 hours after the onset of chest pain, the AUCs were 0.93 (95% CI, 0.88 to 0.99), 0.92 (95% CI, 0.87 to 0.97), 0.92 (95% CI, 0.86 to 0.99), and 0.94 (95% CI, 0.90 to 0.98) for the sensitive assays, respectively, and 0.76 (95% CI, 0.64 to 0.88) for the standard assay. We did not assess the effect of the sensitive troponin assays on clinical management. CONCLUSIONS: The diagnostic performance of sensitive cardiac troponin assays is excellent, and these assays can substantially improve the early diagnosis of acute myocardial infarction, particularly in patients with a recent onset of chest pain. (ClinicalTrials.gov number, NCT00470587.)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa0900428

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,687

Metadata

Authors
Reichlin, T., Hochholzer, W., Bassetti, S., Steuer, S., Stelzig, C., Hartwiger, S., Biedert, S., Schaub, N., Buerge, C., Potocki, M., Noveanu, M., Breidthardt, T., Twerenbold, R., Winkler, K., Bingisser, R., & Mueller, C.
Venue
New England Journal of Medicine
Published
2009-08-27
Volume
361
Issue
9
Pages
858-867
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2098002403
Cited by
1,687
References
1
FWCI
88.18
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays. https://app.cochat.ai/papers/10.1056/nejmoa0900428
The paper
Reichlin, T., Hochholzer, W., Bassetti, S., Steuer, S., Stelzig, C., Hartwiger, S., Biedert, S., Schaub, N., Buerge, C., Potocki, M., Noveanu, M., Breidthardt, T., Twerenbold, R., Winkler, K., Bingisser, R., & Mueller, C. (2009). Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays. New England Journal of Medicine. https://doi.org/10.1056/nejmoa0900428

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.