Cited by 7,205Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesInfective Endocarditis Diagnosis and Management

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery

Open access

Abstract

BACKGROUND: Many patients with severe aortic stenosis and coexisting conditions are not candidates for surgical replacement of the aortic valve. Recently, transcatheter aortic-valve implantation (TAVI) has been suggested as a less invasive treatment for high-risk patients with aortic stenosis. METHODS: We randomly assigned patients with severe aortic stenosis, whom surgeons considered not to be suitable candidates for surgery, to standard therapy (including balloon aortic valvuloplasty) or transfemoral transcatheter implantation of a balloon-expandable bovine pericardial valve. The primary end point was the rate of death from any cause. RESULTS: A total of 358 patients with aortic stenosis who were not considered to be suitable candidates for surgery underwent randomization at 21 centers (17 in the United States). At 1 year, the rate of death from any cause (Kaplan–Meier analysis) was 30.7% with TAVI, as compared with 50.7% with standard therapy (hazard ratio with TAVI, 0.55; 95% confidence interval [CI], 0.40 to 0.74; P<0.001). The rate of the composite end point of death from any cause or repeat hospitalization was 42.5% with TAVI as compared with 71.6% with standard therapy (hazard ratio, 0.46; 95% CI, 0.35 to 0.59; P<0.001). Among survivors at 1 year, the rate of cardiac symptoms (New York Heart Association class III or IV) was lower among patients who had undergone TAVI than among those who had received standard therapy (25.2% vs. 58.0%, P<0.001). At 30 days, TAVI, as compared with standard therapy, was associated with a higher incidence of major strokes (5.0% vs. 1.1%, P=0.06) and major vascular complications (16.2% vs. 1.1%, P<0.001). In the year after TAVI, there was no deterioration in the functioning of the bioprosthetic valve, as assessed by evidence of stenosis or regurgitation on an echocardiogram. CONCLUSIONS: In patients with severe aortic stenosis who were not suitable candidates for surgery, TAVI, as compared with standard therapy, significantly reduced the rates of death from any cause, the composite end point of death from any cause or repeat hospitalization, and cardiac symptoms, despite the higher incidence of major strokes and major vascular events. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1008232

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Show all 43 references

Research works printed but not linked: 2

  1. Murphy ES, 1981, Circulation, 64, II
  2. 10.1016/j.athoracsur.2009.05.056 · DOI

Cited by

Sorted by citations

See all 7,205

Metadata

Authors
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., Brown, D. L., Block, P. C., Guyton, R. A., Pichard, A. D., Bavaria, J. E., Herrmann, H. C., Douglas, P. S., Petersen, J. L., Akin, J. J., Anderson, W. N., Wang, D., & Pocock, S.
Affiliations
  • NewYork–Presbyterian Hospital (US)
  • Medical City Dallas Hospital (US)
  • Stanford Medicine (US)
  • Cleveland Clinic (US)
  • University of British Columbia (CA)
  • Cedars-Sinai Medical Center (US)
  • Emory University (US)
  • MedStar Washington Hospital Center (US)
  • Hospital of the University of Pennsylvania (US)
  • Duke Medical Center (US)
  • Edwards Lifesciences (United States) (US)
  • London School of Hygiene & Tropical Medicine (GB)
Venue
New England Journal of Medicine
Published
2010-10-21
Volume
363
Issue
17
Pages
1597-1607
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2149609916
Cited by
7,205
References
43
Citations by year
2026: 226 · 2025: 309 · 2024: 312 · 2023: 349 · 2022: 374 · 2021: 410 · 2020: 462 · 2019: 521 · 2018: 503 · 2017: 565 · 2016: 555 · 2015: 570 · 2014: 511 · 2013: 580 · 2012: 569
FWCI
335.24
Type
journal article
Language
en
Open access
Locations
  • New England Journal of Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • LSHTM Research Online (London School of Hygiene and Tropical Medicine) (acceptedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
Keywords
transcatheter aortic valve implantation, severe aortic stenosis, inoperable patients, bovine pericardial valve, transfemoral access, balloon aortic valvuloplasty, all-cause mortality, stroke, vascular complications, cardiac symptoms, high-risk surgical patients, bioprosthetic valve durability, recurrent hospitalization
MeSH terms
Aged, Aged, 80 and over, Aortic Valve Stenosis, Cardiovascular Diseases, Catheterization, Echocardiography, Female, Cardiac Catheterization, Hospitalization, Humans, Male, Prospective Studies, Treatment Outcome, Heart Valve Prosthesis Implantation, Kaplan-Meier Estimate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review