The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart Failure
Abstract
BACKGROUND: Cardiac-resynchronization therapy (CRT) benefits patients with left ventricular systolic dysfunction and a wide QRS complex. Most of these patients are candidates for an implantable cardioverter-defibrillator (ICD). We evaluated whether adding CRT to an ICD and optimal medical therapy might reduce mortality and morbidity among such patients. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more or a paced QRS duration of 200 msec or more to receive either an ICD alone or an ICD plus CRT. The primary outcome was death from any cause or hospitalization for heart failure. RESULTS: We followed 1798 patients for a mean of 40 months. The primary outcome occurred in 297 of 894 patients (33.2%) in the ICD-CRT group and 364 of 904 patients (40.3%) in the ICD group (hazard ratio in the ICD-CRT group, 0.75; 95% confidence interval [CI], 0.64 to 0.87; P<0.001). In the ICD-CRT group, 186 patients died, as compared with 236 in the ICD group (hazard ratio, 0.75; 95% CI, 0.62 to 0.91; P = 0.003), and 174 patients were hospitalized for heart failure, as compared with 236 in the ICD group (hazard ratio, 0.68; 95% CI, 0.56 to 0.83; P<0.001). However, at 30 days after device implantation, adverse events had occurred in 124 patients in the ICD-CRT group, as compared with 58 in the ICD group (P<0.001). CONCLUSIONS: Among patients with NYHA class II or III heart failure, a wide QRS complex, and left ventricular systolic dysfunction, the addition of CRT to an ICD reduced rates of death and hospitalization for heart failure. This improvement was accompanied by more adverse events. (Funded by the Canadian Institutes of Health Research and Medtronic of Canada; ClinicalTrials.gov number, NCT00251251.).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Patients with T2DM did not experience a higher rate of complications related to device implantation, including infection.170”
From Type 2 diabetes mellitus and heart failure: A position statement from the Heart Failure Association of the European Society of Cardiology (2018) · cites this paper as [170]
In the citing paper
“Also, subgroup analysis of the RAFT trial showed that the benefit of CRT-D was similar in patients with and without T2DM.170”
From Type 2 diabetes mellitus and heart failure: A position statement from the Heart Failure Association of the European Society of Cardiology (2018) · cites this paper as [170]
Citations
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J., Erdmann, E., Freemantle, N., Gras, D., KAPPENBERGER, L. J., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,300
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
ACC/AHA 2005 Guideline Update for the Diagnosis and Management of Chronic Heart Failure in the Adult
Hunt, S. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.022 · Cited by 4,137
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
Braham, W. I. T. A., Isher, W. E. G. F., Mith, L. S., Elurgio, D. A. B. D., Eon, A. N. R. L., Oh, E., Ocovic, D. U. Z. K., Acker, M. G., Lavell, L. C., Ayes, D. A. L. H., et al. (2002) · Cited by 3,808
Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M. L., Konstam, M. A., MANCINI, D. M., Michl, K., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.192065 · Cited by 3,739
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C. M., Garrigue, S., KAPPENBERGER, L. J., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,718
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
WRITING COMMITTEE MEMBERS, Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.167586 · Cited by 2,251
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,772
Young, J. B., Abraham, W. T., & Smith, A. L. (2003) · ACC Current Journal Review · doi:10.1016/j.accreview.2003.08.087 · Cited by 1,670
2009 Focused Update: ACCF/AHA Guidelines for the Diagnosis and Management of Heart Failure in Adults
Jessup, M. L., Abraham, W. T., Casey, D. E., Feldman, A. M., Francis, G. S., Ganiats, T. G., Konstam, M. A., MANCINI, D. M., Rahko, P. S., Silver, M. A., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.192064 · Cited by 1,425
Linde, C. M., Abraham, W. T., Gold, M. R., Sutton, M. S. J., Ghio, S., & Daubert, J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.027 · Cited by 1,269
Auricchio, A., Stellbrink, C., Sack, S., Block, M. S., Vogt, J. Ü., Bakker, P. F. A., Huth, C., Schöndube, F. A., WOLFHARD, U. F., Böcker, D., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01895-8 · Cited by 1,025
Nelson, G. S., Berger, R. D., Fetics, B. J., Talbot, M. W., Spinelli, J., Hare, J. M., & Kass, D. A. (2000) · Circulation · doi:10.1161/01.cir.102.25.3053 · Cited by 759
Calculating the number needed to treat for trials where the outcome is time to an event
Altman, D. G., & Andersen, P. K. (1999) · BMJ · doi:10.1136/bmj.319.7223.1492 · Cited by 710
Higgins, S. L., Hummel, J. D., Niazi, I. K., GIUDICI, M. C., WORLEY, S. J., Saxon, L. A., BOEHMER, J. P., Higginbotham, M. B., Marco, T. D., Foster, E., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)01042-8 · Cited by 707
Arnold, J. M. O., Liu, P. P., Demers, C., Dorian, P., Giannetti, N., Haddad, H. A., Heckman, G. A., Howlett, J. G., Ignaszewski, A. P., Johnstone, D. E., et al. (2006) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(06)70237-9 · Cited by 410
Sutton, M. G. S. J., Plappert, T. J., Hilpisch, K. E., Abraham, W. T., Hayes, D. L., & Chinchoy, E. C. (2006) · Circulation · doi:10.1161/circulationaha.104.520817 · Cited by 366
León, A. R., Abraham, W. T., Curtis, A. B., Daubert, J. P., Fisher, W. G., Gurley, J. C., Hayes, D. L., Lieberman, R. A., Petersen‐Stejskal, S., & Wheelan, K. R. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.031 · Cited by 249
Effect of Cardiac Resynchronization on Myocardial Efficiency and Regional Oxidative Metabolism
Ukkonen, H., Beanlands, R. S., Burwash, I. G., de Kemp, R., Nahmias, C., Fallen, E. L., Hill, M. R. S., & Tang, A. (2003) · Circulation · doi:10.1161/01.cir.0000047068.02226.95 · Cited by 206
Self-citationMechanism of improvement in mitral regurgitation after cardiac resynchronization therapy
Ypenburg, C., Lancellotti, P., Tops, L. F., Boersma, E. H., Bleeker, G. B., Holman, E. R., Thomas, J. D., Schalij, M. J., Piérard, L., & Bax, J. J. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn063 · Cited by 131
Duray, G. Z., Schmitt, J., Cicek-Hartvig, S., Hohnloser, S. H., & Israel, C. W. (2008) · EP Europace · doi:10.1093/europace/eun322 · Cited by 65
Self-citationResynchronization/defibrillation for ambulatory heart failure trial: rationale and trial design
TANG, A. S. L., Wells, G. A., Arnold, M., Connolly, S. J., Hohnloser, S. H., Nichol, G., Rouleau, J. L., Sheldon, R. S., & Talajic, M. R. (2008) · Current Opinion in Cardiology · doi:10.1097/hco.0b013e32831bc63b · Cited by 53
Self-citationChan, K., Tang, A., Achilli, A., Sassara, M., Bocchiardo, M., Gaïta, F., Cavaglià, S., Hilpisch, K. E., Hill, M. R. S., & Gras, D. (2003) · PubMed · Cited by 18
Self-citationYoung, J. B. (2003) · JAMA · doi:10.1001/jama.289.20.2685 · Cited by 4
Flagged first, then by citations
Research works printed but not linked: 1
- Chan KL, 2003, Can J Cardiol, 19, 387
Cited by
Sorted by citations
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O. D., et al. (2021) · PubMed · doi:10.1093/eurheartj/ehab670 · Cited by 20,604
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes
Knuuti, J., Wijns, W., Saraste, A., Capodanno, D., Barbato, E., Funck-Brentano, C., Prescott, E., Storey, R. F., Deaton, C., Cuisset, T., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz425 · Cited by 7,166
Metadata
- Authors
- Tang, A. S. L., Wells, G. A., Talajic, M., Arnold, M. O., Sheldon, R., Connolly, S., Hohnloser, S. H., Nichol, G., Birnie, D. H., Sapp, J. L., Yee, R., Healey, J. S., & Rouleau, J. L.
- Affiliations
- University of British Columbia (CA)
- Ottawa Heart Institute (CA)
- Montreal Heart Institute (CA)
- London Health Sciences Centre (CA)
- University of Calgary (CA)
- Hamilton Health Sciences (CA)
- Goethe University Frankfurt (DE)
- University of Washington (US)
- Queen Elizabeth II Health Sciences Centre (CA)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2010-12-16
- Volume
- 363
- Issue
- 25
- Pages
- 2385-2395
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2141895646
- Cited by
- 1,859
- References
- 28
- Citations by year
- 2026: 55 · 2025: 67 · 2024: 73 · 2023: 109 · 2022: 76 · 2021: 88 · 2020: 107 · 2019: 99 · 2018: 100 · 2017: 121 · 2016: 141 · 2015: 154 · 2014: 149 · 2013: 190 · 2012: 176
- FWCI
- 113.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Funders
- Canadian Institutes of Health Research
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Keywords
- cardiac resynchronization therapy, implantable cardioverter-defibrillator, heart failure, wide QRS complex, left ventricular systolic dysfunction, mortality, heart failure hospitalization, device implantation complications, optimal medical therapy, left ventricular ejection fraction
- MeSH terms
- Aged, Cardiac Pacing, Artificial, Double-Blind Method, Electrocardiography, Female, Heart Failure, Hospitalization, Humans, Male, Middle Aged, Severity of Illness Index, Defibrillators, Implantable, Ventricular Dysfunction, Left, Kaplan-Meier Estimate, Intention to Treat Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review