The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Open accessAbstract
BACKGROUND: The use of transcatheter aortic-valve replacement has been shown to reduce mortality among high-risk patients with aortic stenosis who are not candidates for surgical replacement. However, the two procedures have not been compared in a randomized trial involving high-risk patients who are still candidates for surgical replacement. METHODS: At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either transcatheter aortic-valve replacement with a balloon-expandable bovine pericardial valve (either a transfemoral or a transapical approach) or surgical replacement. The primary end point was death from any cause at 1 year. The primary hypothesis was that transcatheter replacement is not inferior to surgical replacement. RESULTS: The rates of death from any cause were 3.4% in the transcatheter group and 6.5% in the surgical group at 30 days (P=0.07) and 24.2% and 26.8%, respectively, at 1 year (P=0.44), a reduction of 2.6 percentage points in the transcatheter group (upper limit of the 95% confidence interval, 3.0 percentage points; predefined margin, 7.5 percentage points; P=0.001 for noninferiority). The rates of major stroke were 3.8% in the transcatheter group and 2.1% in the surgical group at 30 days (P=0.20) and 5.1% and 2.4%, respectively, at 1 year (P=0.07). At 30 days, major vascular complications were significantly more frequent with transcatheter replacement (11.0% vs. 3.2%, P<0.001); adverse events that were more frequent after surgical replacement included major bleeding (9.3% vs. 19.5%, P<0.001) and new-onset atrial fibrillation (8.6% vs. 16.0%, P=0.006). More patients undergoing transcatheter replacement had an improvement in symptoms at 30 days, but by 1 year, there was not a significant between-group difference. CONCLUSIONS: In high-risk patients with severe aortic stenosis, transcatheter and surgical procedures for aortic-valve replacement were associated with similar rates of survival at 1 year, although there were important differences in periprocedural risks. (Funded by Edwards Lifesciences; Clinical Trials.gov number, NCT00530894.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Balloon-expandable and self-expanding transcatheter valves have been the most rigorously studied to date, specifically the CoreValve (Medtronic, Dublin, Ireland) and SAPIEN (Edwards, Irvine CA, USA) valves”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“there is a sizable sub-group that dies soon after TAVR or does not experience an improvement in quality of life, suggesting potential futility of TAVR in some patients201;202;220;244;245.”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The prevalence of considerable coronary disease in the setting of severe AS increases with age and was as high as 75% in recent trials comprised mostly of very elderly patients201;220.”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Although, in general, TAVR is associated with a survival advantage compared to conservative (no AVR) management”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Randomized trials of balloon-expandable and self-expanding valves have also demonstrated that TAVR is a viable alternative to surgery in patients at high risk for AVR (Table 4)220;221.”
From Calcific aortic stenosis (2016) · cites this paper as [220]
The cited source says what the claim attributes to it.
In the citing paper
“For patients at high or prohibitive risk of operative mortality, with surgical AVR, TAVR has been a transformative innovation, providing a life-saving treatment for patients who were previously not candidates for AVR”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationPercutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis
Cribier, A. G., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Dérumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,169
Self-citationThe Society of Thoracic Surgeons 2008 Cardiac Surgery Risk Models: Part 2—Isolated Valve Surgery
O’Brien, S. M., Shahian, D. M., Filardo, G., Ferraris, V. A., Haan, C. K., Rich, J. B., Normand, S. T., DeLong, E. R., Shewan, C. M., Dokholyan, R. S., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.05.056 · Cited by 1,259
Shahian, D. M., O’Brien, S. M., Filardo, G., Ferraris, V. A., Haan, C. K., Rich, J. B., Normand, S. T., DeLong, E. R., Shewan, C. M., Dokholyan, R. S., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.05.053 · Cited by 1,256
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M. J., Mehran, R., Miller, D. C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,217
Self-citationBonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190748 · Cited by 1,128
Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery?
Iung, B., Cachier, A., Baron, G., Messika-Zeitoun, D., Delahaye, F., Tornos, P., Gohlke-Bärwolf, C., Boersma, E., Ravaud, P., & Vahanian, A. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi471 · Cited by 1,108
Rodés‐Cabau, J., Webb, J. G., Cheung, A. W., Ye, J., Dumont, É., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 970
Self-citationPercutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E. H., Pasupati, S., & Lichtenstein, S. V. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 897
Self-citationThirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Michev, I., Lange, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.907402 · Cited by 872
Self-citation
Research works printed but not linked: 1
- Murphy ES, 1981, Circulation, 64, II
Cited by
Sorted by citations
Items 601–700 of 1,002
Ullah, W., Zahid, S., Zaidi, S. R., Sarvepalli, D., Haq, S., Roomi, S., Mukhtar, M., Khan, M. A., Gowda, S. N., Ruggiero, N. J., et al. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.121.020906 · Cited by 82
Evolution of Transcatheter Aortic Valve Replacement
Bourantas, C. V., & Serruys, P. W. J. C. (2014) · Circulation Research · doi:10.1161/circresaha.114.302292 · Cited by 82
Yehya, A., Rajagopal, V., Meduri, C., Kauten, J. R., Brown, M., Dean, L., Webster, J., Krishnamoorthy, A., Hrobowski, T. N., & Dean, D. A. (2019) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2019.03.001 · Cited by 82
Schymik, G., Würth, A., Bramlage, P., Herbinger, T., Heimeshoff, M., Pilz, L. R., Schymik, J. S., Wondraschek, R., Süselbeck, T., Gerhardus, J., et al. (2015) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.113.000761 · Cited by 81
AKI after Transcatheter or Surgical Aortic Valve Replacement
Thongprayoon, C., Cheungpasitporn, W., Srivali, N., Harrison, A. M., Gunderson, T. M., Kittanamongkolchai, W., Greason, K. L., & KASHANI, K. B. (2015) · Journal of the American Society of Nephrology · doi:10.1681/asn.2015050577 · Cited by 81
Incidence and Outcomes of Surgical Bailout During TAVR
Pineda, A. M., Harrison, J. K., Kleiman, N. S., Rihal, C. S., Kodali, S., Kirtane, A. J., Leon, M. B., Sherwood, M. W., Manandhar, P., Vemulapalli, S., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.04.026 · Cited by 81
Self-citationCurrent Therapeutic Options in Aortic Stenosis
Boskovski, M. T., & Gleason, T. G. (2021) · Circulation Research · doi:10.1161/circresaha.121.318040 · Cited by 86
McIlroy, D. R., Bellomo, R., Billings, F. T., Karkouti, K., Prowle, J. R., Shaw, A., & Myles, P. S. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.08.010 · Cited by 83
Harris, B. S., Cecco, C. N. D., Schoepf, U. J., Steinberg, D. H., Bayer, R. R., Krazinski, A. W., Dyer, K. T., Sandhu, M. K., Zile, M. R., & Meinel, F. G. (2014) · Radiology · doi:10.1148/radiol.14140763 · Cited by 81
Improving the Methods for the Economic Evaluation of Medical Devices
Tarricone, R., Callea, G., Ogorevc, M., & Rupel, V. P. (2017) · Health Economics · doi:10.1002/hec.3471 · Cited by 81
Blackman, D. J., Baxter, P. D., Gale, C. P., Moat, N. E., MacCarthy, P. A., Hildick‐Smith, D., Trivedi, U., Cunningham, D., de Belder, M., & Ludman, P. (2013) · Journal of Interventional Cardiology · doi:10.1111/joic.12084 · Cited by 80
Ben‐Dor, I., Maluenda, G., Dvir, D., Barbash, I. M., Okubagzi, P. G., Torguson, R., Lindsay, J. M., Satler, L. F., Pichard, A. D., & Waksman, R. (2012) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.24682 · Cited by 80
Self-citationSeiffert, M., Diemert, P., Koschyk, D. H., Schirmer, J. M., Conradi, L., Schnabel, R. B., Blankenberg, S., Reichenspurner, H. C., Baldus, S. E., & Treede, H. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.01.138 · Cited by 80
Muneretto, C., Bisleri, G., Moggi, A., Bacco, L. D., Tespili, M., Repossini, A., & Rambaldini, M. (2014) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivu340 · Cited by 80
Beohar, N., Kirtane, A. J., Blackstone, E. H., Waksman, R., Holmes, D. R., Minha, S., Alli, O. O., Suri, R. M., Svensson, L. G., Leon, M. B., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.10.050 · Cited by 80
Self-citationKhera, S., Kolte, D. S., Gupta, T., Goldsweig, A. M., Velagapudi, P., Kalra, A., Tang, G. H. L., Aronow, W. S., Fonarow, G. C., Bhatt, D. L., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.1630 · Cited by 80
Tam, D. Y., Vo, T. X., Wijeysundera, H. C., Dvir, D., Friedrich, J. O., & Fremes, S. E. (2018) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27686 · Cited by 80
Transcatheter Aortic Valve Implantation in Patients With Severe Left Ventricular Dysfunction
Fraccaro, C., Al-Lamee, R. K., Tarantini, G., Maisano, F., Napodano, M., Montorfano, M., Frigo, A. C., Iliceto, S., Gerosa, G., Isabella, G., et al. (2012) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.111.964213 · Cited by 80
Aortic Valve Reconstruction Using Autologous Pericardium for Aortic Stenosis
Ozaki, S., Kawase, I., Yamashita, H., Uchida, S., Takatoh, M., Hagiwara, S., & Kiyohara, N. (2015) · Circulation Journal · doi:10.1253/circj.cj-14-1092 · Cited by 80
Green, P., Cohen, D. J., Généreux, P., McAndrew, T., Arnold, S. V., Alu, M. C., Beohar, N., Rihal, C. S., Mack, M. J., Kapadia, S. R., et al. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.046 · Cited by 80
Self-citationNakamura, M., Chakravarty, T., Jilaihawi, H., Doctor, N., Dohad, S. Y., Fontana, G. P., Cheng, W., & Makkar, R. (2013) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25130 · Cited by 80
Self-citationSnow, T. M., Ludman, P., BANYA, W. A. S., de Belder, M., MacCarthy, P. A., Davies, S., Mario, C. D., & Moat, N. E. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.06.166 · Cited by 79
Sutureless Aortic Valve Replacement: A Canadian Multicentre Study
Mazine, A., Teoh, K., Bouhout, I., Bhatnagar, G., Pelletier, M. P., Voisine, P., Demers, P., Carrier, M., & Bouchard, D. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.10.030 · Cited by 79
Nguyen, T. C., Babaliaros, V. C., Razavi, S. A., Kilgo, P. D., Guyton, R. A., Devireddy, C. M., Shults, C., Mavromatis, K., Kanitkar, M., Block, P. C., et al. (2013) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2013.07.065 · Cited by 79
Self-citationEffect of Hospital Volume on Outcomes of Transcatheter Aortic Valve Implantation
Badheka, A. O., Patel, N., Panaich, S., Patel, S. D., Jhamnani, S., Singh, V., Pant, S., Patel, N., Patel, N., Arora, S., et al. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.05.019 · Cited by 79
Transapical and Transaortic Transcatheter Aortic Valve Replacement in the United States
Thourani, V. H., Jensen, H., Babaliaros, V. C., Suri, R. M., Vemulapalli, S., Dai, D., Brennan, J. M., Rumsfeld, J. S., Edwards, F. H., Tuzcu, E. M., et al. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.05.010 · Cited by 79
Self-citationYerasi, C., Rogers, T., Forrestal, B. J., Case, B. C., Khan, J. M., Ben‐Dor, I., Satler, L. F., García‐García, H. M., Cohen, J. E., Kitahara, H., et al. (2021) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2021.03.058 · Cited by 79
2026 ESC Guidelines for the management of heart failure
Køber, L., Adamo, M., Ruwald, A., Tomasoni, D., Anderson, L., Andersson, C., Brugts, J. J., Chioncel, O. D., Donal, E., Ferdinandy, P., et al. (2026) · European Heart Journal · doi:10.1093/eurheartj/ehag100 · Cited by 109
Khawaja, M. Z., Thomas, M., Joshi, A., Asrress, K., Wilson, K., Bolter, K., Young, C. P., Hancock, J., Bapat, V., & Redwood, S. R. (2012) · EuroIntervention · doi:10.4244/eijv8i5a87 · Cited by 79
Matsumoto, S., Yamada, Y., Hashimoto, M., Okamura, T., Yamada, M., Yashima, F., Hayashida, K., Fukuda, K., & Jinzaki, M. (2016) · European Radiology · doi:10.1007/s00330-016-4547-4 · Cited by 79
Svensson, L. G., Blackstone, E. H., Apperson-Hansen, C., Ruggieri, P. M., Ainkaran, P., Naugle, R. I., Lima, B., Roselli, E. E., Cooper, M., Somogyi, D., et al. (2015) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2015.07.054 · Cited by 78
Self-citationCharacterization of Neurological Injury in Transcatheter Aortic Valve Implantation
Fanning, J. P., Walters, D., Platts, D. G., Eeles, E. M., Bellapart, J., & Fraser, J. F. (2014) · Circulation · doi:10.1161/circulationaha.113.004103 · Cited by 78
Imaging to select and guide transcatheter aortic valve implantation
Zamorano, J. L., Gonçalves, A., & Lang, R. M. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht569 · Cited by 78
The development of transcatheter aortic valve replacement (TAVR)
Cribier, A. G. (2017) · Global Cardiology Science and Practice · doi:10.21542/gcsp.2016.32 · Cited by 78
Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside
Saxon, J. T., Allen, K. B., Cohen, D. J., & Chhatriwalla, A. K. (2017) · Interventional Cardiology Reviews Research Resources · doi:10.15420/icr.2017:29:1 · Cited by 78
Early Versus Standard Discharge After Transcatheter Aortic Valve Replacement
Kotronias, R. A., Teitelbaum, M., Webb, J. G., Mylotte, D., Barbanti, M., Wood, D. A., Ballantyne, B. A., Osborne, A., Solo, K., Kwok, C. S., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.04.042 · Cited by 78
Self-citationLansky, A. J., Makkar, R. R., Nazif, T. M., Messe, S. R., Forrest, J. K., Sharma, R. P., Schöfer, J., Linke, A. H.-P., Brown, D. L., Dhoble, A., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab213 · Cited by 78
Self-citationRusso, N., Compostella, L., Tarantini, G., Setzu, T., Napodano, M., Bottio, T., D’Onofrio, A., Isabella, G., Gerosa, G., Iliceto, S., et al. (2013) · European Journal of Preventive Cardiology · doi:10.1177/2047487313494029 · Cited by 78
Kapadia, S. R., Huded, C. P., Kodali, S., Svensson, L. G., Tuzcu, E. M., Baron, S. J., Cohen, D. J., Miller, D. C., Thourani, V. H., Herrmann, H. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.2172 · Cited by 78
Self-citationA Call for an Evidence-Based Approach to the Heart Team for Patients With Severe Aortic Stenosis
Coylewright, M. J., Mack, M. J., Holmes, D. R., & O’Gara, P. T. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.02.033 · Cited by 77
Self-citationHayashida, K., Romano, M., Lefèvre, T., Chevalier, B., Farge, A., Hovasse, T., Houérou, D. L., & Morice, M. (2013) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezt037 · Cited by 77
Initial Experience of a Second-Generation Self-Expanding Transcatheter Aortic Valve
Kalra, S. S., Firoozi, S., Yeh, J., Blackman, D. J., Rashid, S., Davies, S., Moat, N. E., Dalby, M. C. D., Kabir, T., Khogali, S., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.11.025 · Cited by 77
Fujita, B., Schmidt, T., Bleiziffer, S., Bauer, T., Beckmann, A., Bekeredjian, R., Möllmann, H., Walther, T., Landwehr, S., Hamm, C. W., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz168 · Cited by 77
Bosmans, J. M., Bleiziffer, S., Gerckens, U. J., Wenaweser, P., Brecker, S. J., Tamburino, C., & Linke, A. H.-P. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.05.025 · Cited by 77
Pasic, M., Dreysse, S. T., Unbehaun, A., Buz, S., Drews, T., Klein, C., D’Ancona, G., & Hetzer, R. (2012) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivr144 · Cited by 77
Braghiroli, J., Kapoor, K., Thielhelm, T. P., Ferreira, T., & Cohen, M. G. (2020) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2019.09.12 · Cited by 77
Nijenhuis, V. J., Bennaghmouch, N., Hassell, M. E. C. J., Baan, J., van Kuijk, J. P., Agostoni, P., Hof, A. W. J. V. ’., Kievit, P. C., Veenstra, L. F., van der Harst, P., et al. (2015) · American Heart Journal · doi:10.1016/j.ahj.2015.11.008 · Cited by 76
3rd GUIDELINE FOR PERIOPERATIVE CARDIOVASCULAR EVALUATION OF THE BRAZILIAN SOCIETY OF CARDIOLOGY
Gualandro, D., Yu, P., Caramelli, B., Marques, A., Calderaro, D., Fornari, L. S., Pinho, C., Feitosa, A. K. N., Polanczyk, C. A., Rochitte, C. E., et al. (2017) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20170140 · Cited by 79
Need for Permanent Pacemaker After Surgical Aortic Valve Replacement Reduces Long-Term Survival
Mehaffey, J. H., Haywood, N. S., Hawkins, R. B., Kern, J. A., Teman, N. R., Kron, I. L., Yarboro, L. T., & Ailawadi, G. (2018) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.02.041 · Cited by 76
Pre-procedural fit-testing of TAVR valves using parametric modeling and 3D printing
Hosny, A., Dilley, J. D., Kelil, T., Mathur, M., Dean, M. N., Weaver, J. C., & Ripley, B. A. (2018) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2018.09.007 · Cited by 76
Life Expectancy After Surgical Aortic Valve Replacement
Martinsson, A., Nielsen, S. J., Milojevic, M., Redfors, B., Ömerovic, E., Tønnessen, T., Guðbjartsson, T., Dellgren, G., & Jeppsson, A. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.861 · Cited by 76
Transapical Transcatheter Aortic Valve for Severe Aortic Regurgitation
Wendt, D., Kahlert, P., Pasa, S., Chilali, K. E., Al‐Rashid, F., Tsagakis, K., Dohle, D., Erbel, R., Jakob, H. G., & Thielmann, M. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.04.016 · Cited by 76
Gender differences in patients undergoing TAVI: a multicentre study
D’Ascenzo, F., Gonella, A., Moretti, C., Omedè, P., Salizzoni, S., Torre, M. L., Giordana, F., Barbanti, M., Ussia, G. P., Brambilla, N., et al. (2013) · EuroIntervention · doi:10.4244/eijv9i3a59 · Cited by 76
Asami, M., Lanz, J., Stortecky, S., Räber, L., Franzone, A., Heg, D., Hunziker, L., Roost, E., Siontis, G. C. M., Valgimigli, M., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.01.240 · Cited by 76
Lindman, B. R., Pibarot, P., Arnold, S. V., Suri, R. M., McAndrew, T. C., Maniar, H. S., Zajarias, A., Kodali, S., Kirtane, A. J., Thourani, V. H., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.057 · Cited by 75
Self-citationSchymik, G., Heimeshoff, M., Bramlage, P., Herbinger, T., Würth, A., Pilz, L. R., Schymik, J. S., Wondraschek, R., Süselbeck, T., Gerhardus, J., et al. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25866 · Cited by 75
Sinning, J., Horack, M., Grube, E., Gerckens, U. J., Erbel, R., Eggebrecht, H., Zahn, R., Linke, A. H.-P., Sievert, H., Figulla, H., et al. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.04.016 · Cited by 75
Onsea, K., Agostoni, P., Samim, M., Voskuil, M., Kluin, J., Budde, R. P. J., Hendrikse, J., Ramjankhan, F. Z., van Klarenbosch, J., Doesburg, P., et al. (2012) · EuroIntervention · doi:10.4244/eijv8i1a9 · Cited by 75
Serruys, P. W. J. C., Modolo, R., Reardon, M. J., Miyazaki, Y., Windecker, S., Popma, J. J., Chang, Y., Kleiman, N. S., Lilly, S. M., Amrane, H., et al. (2018) · EuroIntervention · doi:10.4244/eij-d-18-00460 · Cited by 75
Faurie, B., Souteyrand, G., Staat, P., Godin, M., Caussin, C., BELLE, E. V., Mangin, L., Meyer, P., Dumonteil, N., Abdellaoui, M., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.09.029 · Cited by 75
Shroff, G. R., Bangalore, S., Bhave, N. M., Chang, T. I., García, S., Mathew, R. O., Rangaswami, J., Ternacle, J., Thourani, V. H., & Pîbarot, P. (2021) · Circulation · doi:10.1161/cir.0000000000000979 · Cited by 76
Self-citationCT and MR Imaging of the Aortic Valve: Radiologic-Pathologic Correlation
Bennett, C. J., Maleszewski, J. J., & Araoz, P. A. (2012) · Radiographics · doi:10.1148/rg.325115727 · Cited by 75
Rossi, A., Cecco, C. N. D., Kennon, S. R. O., Zou, L., Meinel, F. G., Toscano, W., Segreto, S., Achenbach, S. S., Hausleiter, J., Schoepf, U. J., et al. (2017) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2017.06.001 · Cited by 75
Moriyama, N., Laakso, T., Biancari, F., Raivio, P. M., Jalava, M. P., Jaakkola, J., Dahlbacka, S., Kinnunen, E., Juvonen, T. S., Husso, A., et al. (2019) · EuroIntervention · doi:10.4244/eij-d-19-00247 · Cited by 81
Testa, L., Latib, A., Brambilla, N., MARCO, F. D., Fiorina, C., Adamo, M., Giannini, C., Angelillis, M., Barbanti, M., Sgroi, C., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz925 · Cited by 75
Meredith, I. T., Hood, K. L., Haratani, N., Allocco, D. J., & Dawkins, K. D. (2012) · EuroIntervention · doi:10.4244/eijv8sqa12 · Cited by 74
Petronio, A. S., Angelillis, M., Backer, O. D., Giannini, C., Costa, G., Fiorina, C., Castriota, F., Bedogni, F., Laborde, J. C., & Søndergaard, L. (2020) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2020.01.007 · Cited by 74
Laakso, T., Laine, M., Moriyama, N., Dahlbacka, S., Airaksinen, J. K. E., Virtanen, M. P. O., Husso, A., Tauriainen, T., Niemelä, M. J., Mäkikallio, T. H., et al. (2020) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezaa254 · Cited by 77
Swift, S. L., Puehler, T., Misso, K., Lang, S., Forbes, C. A., Kleijnen, J., Danner, M., Kühn, C., Haneya, A., Seoudy, H., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-054222 · Cited by 74
Bleeding Events After Transcatheter Aortic Valve Replacement
Avvedimento, M., Nuche, J., Farjat-Pasos, J. I., & Rodés‐Cabau, J. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.11.050 · Cited by 74
Sannino, A., Losi, M. A., Schiattarella, G. G., Gargiulo, G., Perrino, C., Stabile, E., Toscano, E., Giugliano, G., Brevetti, L., Franzone, A., et al. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.06.022 · Cited by 74
Transcatheter Valve-In-Valve Implantation for Failed Balloon-Expandable Transcatheter Aortic Valves
Toggweiler, S., Wood, D. A., Rodés‐Cabau, J., Kapadia, S. R., Willson, A. B., Ye, J., Cheung, A. W., Leipsic, J. A., Binder, R. K., Gurvitch, R., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.03.008 · Cited by 74
Self-citationPredictors and Prognostic Value of Myocardial Injury During Transcatheter Aortic Valve Implantation
Yong, Z. Y., Wiegerinck, E. M. A., Dijk, K. B., Koch, K. T., Vis, M. M., Bouma, B. J., Henriques, J. P. S., Cocchieri, R., Piek, J. J., de Mol, B. A. J. M., et al. (2012) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.111.964882 · Cited by 74
Griese, D. P., Reents, W., Tóth, A., Kerber, S., Diegeler, A., & Babin–Ebell, J. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu187 · Cited by 74
Saji, M., Lim, D. S., Ragosta, M., LaPar, D. J., Downs, E., Ghanta, R. K., Kern, J. A., Dent, J. M., & Ailawadi, G. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2016.04.043 · Cited by 74
Jensen, H., Condado, J. F., Devireddy, C. M., Binongo, J., Leshnower, B. G., Babaliaros, V. C., Sarin, E. L., Lerakis, S., Guyton, R. A., Stewart, J. P., et al. (2015) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2015.07.078 · Cited by 73
Self-citationThrombo-embolic prevention after transcatheter aortic valve implantation
Vranckx, P., Windecker, S., Welsh, R. C., Valgimigli, M., Mehran, R., & Dangas, G. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx390 · Cited by 73
Transcatheter aortic valve implantation in lower-risk patients: what is the perspective?
Tarantini, G., Fovino, L. N., & Gersh, B. J. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx489 · Cited by 73
Outcome after transvascular transcatheter aortic valve implantation in 2016
Gaede, L., Blumenstein, J., Liebetrau, C., Dörr, O., Kim, W., NEF, H. M., Hüsser, O., Elsässer, A., Hamm, C. W., & Möllmann, H. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx688 · Cited by 73
Mieghem, N. M. V., Unverdorben, M., Valgimigli, M., Mehran, R., Boersma, E. H., Baber, U., Hengstenberg, C., Shi, M., Chen, C. Y.-H., Saito, S., et al. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.07.006 · Cited by 75
Impact of Transcatheter Aortic Valve Replacement on Severity of Chronic Kidney Disease
Cubeddu, R. J., Asher, C. R., Lowry, A. M., Blackstone, E. H., Kapadia, S. R., Alu, M. C., Thourani, V. H., Mack, M. J., Kodali, S., Herrmann, H. C., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.07.048 · Cited by 73
Self-citationTAVR: A Review of Current Practices and Considerations in Low-Risk Patients
Spears, J., Al-Saiegh, Y., Goldberg, D. M., Manthey, S., & Goldberg, S. (2020) · Journal of Interventional Cardiology · doi:10.1155/2020/2582938 · Cited by 75
Moreira, R., Velz, T., Alves, N. M., Gesche, V. N., Malischewski, A., Schmitz‐Rode, T., Frese, J., Jockenhoevel, S., & Mela, P. (2014) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2014.0214 · Cited by 73
Völler, H., Salzwedel, A., Nitardy, A., Buhlert, H., Treszl, A., & Wegscheider, K. (2014) · European Journal of Preventive Cardiology · doi:10.1177/2047487314526072 · Cited by 73
The rise of cardiovascular medicine
Braunwald, E. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr452 · Cited by 73
Spaziano, M., Mylotte, D., Thériault-Lauzier, P., Backer, O. D., Søndergaard, L., Bosmans, J. M., Debry, N., Modine, T., Barbanti, M., Tamburino, C., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-16-00303 · Cited by 73
Howell, N. J., Head, S. J., Freemantle, N., van der Meulen, T. A., Senanayake, E. L., Menon, A., Kappetein, A. P., & Pagano, D. (2013) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezt174 · Cited by 72
Systemic inflammatory response syndrome after transcatheter or surgical aortic valve replacement
Lindman, B. R., Goldstein, J., Nassif, M. E., Zajarías, A., Novak, E. L., Tibrewala, A., Vatterott, A. M., Lawler, C., Damiano, R. J., Moon, M. R., et al. (2015) · Heart · doi:10.1136/heartjnl-2014-307057 · Cited by 74
Yamamoto, M., Watanabe, Y., Tada, N., Naganuma, T., Araki, M., Yamanaka, F., Mizutani, K., Tabata, M., Ueno, H., Takagi, K., et al. (2018) · Cardiovascular revascularization medicine · doi:10.1016/j.carrev.2018.11.024 · Cited by 72
TAVI and the future of aortic valve replacement
Howard, C., Jullian, L., Joshi, M., Noshirwani, A., Bashir, M., & Harky, A. (2019) · Journal of Cardiac Surgery · doi:10.1111/jocs.14226 · Cited by 72
Masha, L., Vemulapalli, S., Manandhar, P., Balan, P., Shah, P. B., Kosinski, A. S., & Stewart, G. C. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.02.033 · Cited by 72
Potpara, T., Grygier, M., Hæusler, K. G., Nielsen‐Kudsk, J. E., Berti, S. L., Genovesi, S., Marijon, É., Bovéda, S., Tzikas, A., Boriani, G., et al. (2024) · EP Europace · doi:10.1093/europace/euae035 · Cited by 78
Stem Cell–Based Transcatheter Aortic Valve Implantation
Emmert, M. Y., Weber, B., Wolint, P., Behr, L., Sammut, S., Frauenfelder, T., Frese, L., Scherman, J., Brokopp, C. E., Templin, C., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.04.010 · Cited by 72
Dvir, D., Webb, J. G., Piazza, N., Blanke, P., Barbanti, M., Bleiziffer, S., Wood, D. A., Mylotte, D., Wilson, A., Tan, J., et al. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25823 · Cited by 72
Self-citationBaumbach, A., Mullen, M. J., Brickman, A. M., Aggarwal, S. K., Pietras, C. G., Forrest, J. K., Hildick‐Smith, D., Meller, S. M., Gambone, L., den Heijer, P., et al. (2015) · EuroIntervention · doi:10.4244/eijy15m04_01 · Cited by 72
Liao, Y., Deng, X., Meng, Y., Zhao, Z., Xiong, T., Meng, X., Zuo, Z., Li, Y., Cao, J., Xu, Y., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-15-00254 · Cited by 72
Local and general anaesthesia do not influence outcome of transfemoral aortic valve implantation
Dall’Ara, G., Eltchaninoff, H., Moat, N. E., Laroche, C., Goicolea, J., Ussia, G. P., Kala, P., Wenaweser, P., Zembala, M., Nickenig, G., et al. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.09.025 · Cited by 71
Kadakia, M. B., Herrmann, H. C., Desai, N. D., Fox, Z. E., Ogbara, J., Anwaruddin, S., Jagasia, D. H., Bavaria, J. E., Szeto, W. Y., Vallabhajosyula, P., et al. (2014) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.113.001030 · Cited by 71
Self-citationTranscatheter aortic valve implantation (TAVI): risky and costly
Brabandt, H. V., Neyt, M., & Hulstaert, F. (2012) · BMJ · doi:10.1136/bmj.e4710 · Cited by 71
Thourani, V. H., Li, C., Devireddy, C. M., Jensen, H., Kilgo, P., Leshnower, B. G., Mavromatis, K., Sarin, E. L., Nguyen, T. C., Kanitkar, M., et al. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2014.10.012 · Cited by 71
Self-citation
Metadata
- Authors
- Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., Williams, M., Dewey, T., Kapadia, S., Babaliaros, V., Thourani, V. H., Corso, P., Pichard, A. D., Bavaria, J. E., Herrmann, H. C., Akin, J. J., Anderson, W. N., Wang, D., & Pocock, S. J.
- Affiliations
- NewYork–Presbyterian Hospital (US)
- Baylor Scott & White Health (US)
- Stanford Medicine (US)
- Cleveland Clinic (US)
- University of British Columbia (CA)
- Cedars-Sinai Medical Center (US)
- Medical City Dallas Hospital (US)
- Emory University (US)
- MedStar Washington Hospital Center (US)
- Hospital of the University of Pennsylvania (US)
- Edwards Lifesciences (United States) (US)
- London School of Hygiene & Tropical Medicine (GB)
- ORCID
- Smith, Craig R.
- Leon, Martin B.
- Mack, Michael J.
- Miller, D. Craig
- Moses, Jeffrey W.
- Svensson, Lars G.
- Tuzcu, E. Murat
- Webb, John G.
- Fontana, Gregory P.
- Makkar, Raj R.
- Williams, Mathew
- Kapadia, Samir
- Babaliaros, Vasilis
- Thourani, Vinod H.
- Bavaria, Joseph E.
- Herrmann, Howard C.
- Anderson, William N.
- Wang, Duolao
- Pocock, Stuart J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2011-06-09
- Volume
- 364
- Issue
- 23
- Pages
- 2187-2198
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2165258820
- Cited by
- 6,345
- References
- 44
- Citations by year
- 2026: 194 · 2025: 239 · 2024: 315 · 2023: 331 · 2022: 340 · 2021: 396 · 2020: 457 · 2019: 507 · 2018: 503 · 2017: 545 · 2016: 533 · 2015: 502 · 2014: 455 · 2013: 484 · 2012: 449
- FWCI
- 322.18
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- LSHTM Research Online (London School of Hygiene and Tropical Medicine) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- transcatheter aortic valve implantation, surgical aortic valve replacement, severe aortic stenosis, high-risk patients, transapical approach, transfemoral access, non-inferiority, mortality, stroke, vascular complications, hemorrhage, atrial fibrillation, periprocedural risk, symptom improvement, randomized trial comparison
- MeSH terms
- Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Stenosis, Cardiovascular Diseases, Catheterization, Female, Cardiac Catheterization, Humans, Male, Postoperative Complications, Risk Factors, Heart Valve Prosthesis Implantation, Stroke, Intention to Treat Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›