The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Open accessAbstract
BACKGROUND: The use of transcatheter aortic-valve replacement has been shown to reduce mortality among high-risk patients with aortic stenosis who are not candidates for surgical replacement. However, the two procedures have not been compared in a randomized trial involving high-risk patients who are still candidates for surgical replacement. METHODS: At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either transcatheter aortic-valve replacement with a balloon-expandable bovine pericardial valve (either a transfemoral or a transapical approach) or surgical replacement. The primary end point was death from any cause at 1 year. The primary hypothesis was that transcatheter replacement is not inferior to surgical replacement. RESULTS: The rates of death from any cause were 3.4% in the transcatheter group and 6.5% in the surgical group at 30 days (P=0.07) and 24.2% and 26.8%, respectively, at 1 year (P=0.44), a reduction of 2.6 percentage points in the transcatheter group (upper limit of the 95% confidence interval, 3.0 percentage points; predefined margin, 7.5 percentage points; P=0.001 for noninferiority). The rates of major stroke were 3.8% in the transcatheter group and 2.1% in the surgical group at 30 days (P=0.20) and 5.1% and 2.4%, respectively, at 1 year (P=0.07). At 30 days, major vascular complications were significantly more frequent with transcatheter replacement (11.0% vs. 3.2%, P<0.001); adverse events that were more frequent after surgical replacement included major bleeding (9.3% vs. 19.5%, P<0.001) and new-onset atrial fibrillation (8.6% vs. 16.0%, P=0.006). More patients undergoing transcatheter replacement had an improvement in symptoms at 30 days, but by 1 year, there was not a significant between-group difference. CONCLUSIONS: In high-risk patients with severe aortic stenosis, transcatheter and surgical procedures for aortic-valve replacement were associated with similar rates of survival at 1 year, although there were important differences in periprocedural risks. (Funded by Edwards Lifesciences; Clinical Trials.gov number, NCT00530894.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Balloon-expandable and self-expanding transcatheter valves have been the most rigorously studied to date, specifically the CoreValve (Medtronic, Dublin, Ireland) and SAPIEN (Edwards, Irvine CA, USA) valves”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“there is a sizable sub-group that dies soon after TAVR or does not experience an improvement in quality of life, suggesting potential futility of TAVR in some patients201;202;220;244;245.”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The prevalence of considerable coronary disease in the setting of severe AS increases with age and was as high as 75% in recent trials comprised mostly of very elderly patients201;220.”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Although, in general, TAVR is associated with a survival advantage compared to conservative (no AVR) management”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Randomized trials of balloon-expandable and self-expanding valves have also demonstrated that TAVR is a viable alternative to surgery in patients at high risk for AVR (Table 4)220;221.”
From Calcific aortic stenosis (2016) · cites this paper as [220]
The cited source says what the claim attributes to it.
In the citing paper
“For patients at high or prohibitive risk of operative mortality, with surgical AVR, TAVR has been a transformative innovation, providing a life-saving treatment for patients who were previously not candidates for AVR”
From Calcific aortic stenosis (2016) · cites this paper as [220]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationPercutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis
Cribier, A. G., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Dérumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,169
Self-citationThe Society of Thoracic Surgeons 2008 Cardiac Surgery Risk Models: Part 2—Isolated Valve Surgery
O’Brien, S. M., Shahian, D. M., Filardo, G., Ferraris, V. A., Haan, C. K., Rich, J. B., Normand, S. T., DeLong, E. R., Shewan, C. M., Dokholyan, R. S., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.05.056 · Cited by 1,259
Shahian, D. M., O’Brien, S. M., Filardo, G., Ferraris, V. A., Haan, C. K., Rich, J. B., Normand, S. T., DeLong, E. R., Shewan, C. M., Dokholyan, R. S., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.05.053 · Cited by 1,256
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M. J., Mehran, R., Miller, D. C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,217
Self-citationBonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C., Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O’Gara, P. T., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190748 · Cited by 1,128
Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery?
Iung, B., Cachier, A., Baron, G., Messika-Zeitoun, D., Delahaye, F., Tornos, P., Gohlke-Bärwolf, C., Boersma, E., Ravaud, P., & Vahanian, A. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi471 · Cited by 1,108
Rodés‐Cabau, J., Webb, J. G., Cheung, A. W., Ye, J., Dumont, É., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 970
Self-citationPercutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E. H., Pasupati, S., & Lichtenstein, S. V. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 897
Self-citationThirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Michev, I., Lange, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.907402 · Cited by 872
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- Murphy ES, 1981, Circulation, 64, II
Cited by
Sorted by citations
Items 801–900 of 1,002
Kempfert, J., Treede, H., Rastan, A. J., Schönburg, M., Thielmann, M., Sorg, S., Mohr, F. W., & Walther, T. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs139 · Cited by 61
Xiong, T., Liao, Y., Zhao, Z., Xu, Y., Wei, X., Zuo, Z., Li, Y., Cao, J., Tang, H., Jilaihawi, H., et al. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.115.002096 · Cited by 61
Kong, W. Y., Yong, G., & Irish, A. B. (2012) · Nephrology · doi:10.1111/j.1440-1797.2012.01593.x · Cited by 61
Maan, A., Heist, E. K., Passeri, J. J., Inglessis, I., Baker, J. N., Ptaszek, L. M., Vlahakes, G. J., Ruskin, J. N., Palacios, I. F., Sundt, T. M., et al. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.10.027 · Cited by 61
Panchal, H. B., Ladia, V. M., Desai, S., Shah, T., & Ramu, V. K. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.05.015 · Cited by 62
Transcatheter aortic valve implantation (TAVI): Valve design and evolution
Fanning, J. P., Platts, D. G., Walters, D., & Fraser, J. F. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.07.117 · Cited by 61
Attizzani, G. F., Alkhalil, A., Padaliya, B. B., Tam, C.-C., Lopes, J. P., Fares, A., Bezerra, H. G., Medalion, B., Park, S., Deo, S. V., et al. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.08.044 · Cited by 61
Sabaté, M., Cánovas, S., García, E., Antolín, R. H., Maroto, L. C., Hernández, J. M., Briales, J. H. A., Muñoz-García, A. J., Gutiérrez, E., & Centeno, J. (2013) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.07.003 · Cited by 61
Mangner, N., Crusius, L., Haußig, S., Woitek, F. J., Kiefer, P., Stachel, G., Leontyev, S., Schlotter, F., Spindler, A., Höllriegel, R., et al. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.12.042 · Cited by 61
Bioprosthetic Heart Valves: Upgrading a 50-Year Old Technology
Li, K. Y. C. (2019) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2019.00047 · Cited by 61
Panoulas, V. F., Francis, D. P., Ruparelia, N., Malik, I. S., Chukwuemeka, A. O., Sen, S., Anderson, J. R., Nihoyannopoulos, P., Sutaria, N., Hannan, E. L., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.05.047 · Cited by 60
Self-citationKheradvar, A., Groves, E. M., Goergen, C. J., Alavi, S. H., Tranquillo, R. T., Simmons, C. A., Dasi, L. P., Grande-Allen, K. J., Mofrad, M. R. K., Falahatpisheh, A., et al. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1191-5 · Cited by 60
D’Ascenzo, F., Moretti, C., Salizzoni, S., Bollati, M., D’Amico, M., Ballocca, F., Giordana, F., Barbanti, M., Ussia, G. P., Brambilla, N., et al. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.04.161 · Cited by 60
Sinning, J., Hammerstingl, C., Schueler, R., Neugebauer, A., Keul, S., Ghanem, A., Mellert, F., Schiller, W., Müller, C., Vasa‐Nicotera, M., et al. (2016) · EuroIntervention · doi:10.4244/eijy15m02_02 · Cited by 60
Jhaveri, K. D., Saratzis, A. N., Wanchoo, R., & Sarafidis, P. A. (2017) · Kidney International · doi:10.1016/j.kint.2016.11.030 · Cited by 60
Foldyna, B., Troschel, F. M., Addison, D., Fintelmann, F. J., Elmariah, S., Furman, D., Eslami, P., Ghoshhajra, B. B., Lu, M. T., Murthy, V. L., et al. (2018) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2018.03.007 · Cited by 60
Assessment of Platelet REACtivity After Transcatheter Aortic Valve Replacement
Díaz, V. A. J., Tello‐Montoliu, A., Moreno, R., Cruz‐González, I., Alonso, J. A. B., Romaguera, R., Navarro, E. M., Juan‐Salvadores, P., Paredes-Galán, E., Castro, A. D. M., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.10.005 · Cited by 60
The Fate of Transcaval Access Tracts
Lederman, R. J., Babaliaros, V. C., Rogers, T., Stine, A. M., Chen, M. Y., Muhammad, K. I., Leonardi, R. A., Paone, G., Khan, J. M., Leshnower, B. G., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.11.035 · Cited by 60
Self-citationTranscatheter aortic valve replacement: current perspectives and future implications
Agarwal, S., Tuzcu, E. M., Krishnaswamy, A., Schoenhagen, P., Stewart, W. J., Svensson, L. G., & Kapadia, S. R. (2014) · Heart · doi:10.1136/heartjnl-2014-306254 · Cited by 59
Self-citationPatsalis, P., Al‐Rashid, F., Neumann, T., Plicht, B., Hildebrandt, H. A., Wendt, D., Thielmann, M., Jakob, H. G., Heusch, G., Erbel, R., et al. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.05.006 · Cited by 59
García-Valentín, A., Mestres, C. A., Bernabeu, E., Bahamonde, J. Á., Martín, I., Rueda, C., Domenech, A., Valencia, J., Fletcher, D., Machado, F., et al. (2015) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezv090 · Cited by 59
Kamperidis, V., Joyce, E., Debonnaire, P., Katsanos, S., van Rosendael, P. J., van der Kley, F., Sianos, G., Bax, J. J., Marsan, N. A., & Delgado, V. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.04.021 · Cited by 59
Gada, H., Kapadia, S. R., Tuzcu, E. M., Svensson, L. G., & Marwick, T. H. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.12.030 · Cited by 59
Self-citationHüsser, O., Holzamer, A., Philipp, A., Núñez, J. E., Bodı́, V., Müller, T. M., Lubnow, M., Luchner, A., Lunz, D., Riegger, G. A. J., et al. (2013) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.24806 · Cited by 59
Percutaneous Aortic Balloon Valvotomy in the United States: A 13-Year Perspective
Badheka, A. O., Patel, N., Singh, V., Shah, N. N., Chothani, A., Mehta, K. D., Deshmukh, A. J., Ghatak, A., Rathod, A. D., Desai, H. V., et al. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2014.02.025 · Cited by 59
Self-citationLi, K., & Sun, W. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2814 · Cited by 59
The Future of Cardiovascular Imaging
Carli, M. F. D., Geva, T., & Davidoff, R. (2016) · Circulation · doi:10.1161/circulationaha.116.023511 · Cited by 59
The Perceval Sutureless Aortic Valve
Powell, R., Pelletier, M. P., Chu, M. W. A., Bouchard, D., Melvin, K. N., & Adams, C. A. (2017) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0000000000000372 · Cited by 59
Elmariah, S., Fearon, W. F., Inglessis, I., Vlahakes, G. J., Lindman, B. R., Alu, M. C., Crowley, A., Kodali, S., Leon, M. B., Svensson, L. G., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.09.023 · Cited by 59
Self-citationMao, W., Wang, Q., Kodali, S., & Sun, W. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4040457 · Cited by 59
Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis
Lindman, B. R., Otto, C. M., Douglas, P. S., Hahn, R. T., Elmariah, S., Weissman, N. J., Stewart, W. J., Ayele, G. M., Zhang, F., Zajarías, A., et al. (2017) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.116.006308 · Cited by 60
Self-citationSex-Specific Determinants of Outcomes After Transcatheter Aortic Valve Replacement
Pighi, M., Piazza, N., Martucci, G. J., Lachapelle, K. J., Perrault, L. P., Asgar, A., Lauck, S., Webb, J. G., Popma, J. J., Kim, D. H., et al. (2019) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.118.005363 · Cited by 59
Self-citationKosmidou, I., Liu, Y., Alu, M. C., Liu, M., Madhavan, M. V., Chakravarty, T., Makkar, R., Thourani, V. H., BIVIANO, A. B., Kodali, S., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.06.001 · Cited by 59
Self-citationKondur, A., Briasoulis, Α., Palla, M., Penumetcha, A., Mallikethi‐Reddy, S., Badheka, A., & SCHREIBER, T. L. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.10.034 · Cited by 58
Mieghem, N. M. V., Head, S. J., van der Boon, R. M. A., Piazza, N., de Jaegere, P. P. T., Carrel, T. P., Kappetein, A. P., Lange, R. S., Walther, T., Windecker, S., et al. (2012) · EuroIntervention · doi:10.4244/eijv8i2a40 · Cited by 58
Gaede, L., Blumenstein, J., Kim, W., Liebetrau, C., Dörr, O., NEF, H. M., Hamm, C. W., Elsässer, A., & Möllmann, H. (2017) · Clinical Research in Cardiology · doi:10.1007/s00392-016-1070-1 · Cited by 58
Möllmann, H., Linke, A. H.-P., Holzhey, D. M., Walther, T., Manoharan, G., Schäfer, U., Kück, K., Boven, A. J. V., Redwood, S. R., Kováč, J., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.05.021 · Cited by 58
Kolte, D. S., Bhardwaj, B., Lu, M., Alu, M. C., Passeri, J. J., Inglessis, I., Vlahakes, G. J., Garcia, S. A., Cohen, D. J., Lindman, B. R., et al. (2022) · JAMA Cardiology · doi:10.1001/jamacardio.2022.2222 · Cited by 58
Self-citationTrauzeddel, R. F., Löbe, U., Barker, A. J., Gelsinger, C., Butter, C., Markl, M., Schulz‐Menger, J., & von Knobelsdorff‐Brenkenhoff, F. (2015) · International journal of cardiac imaging · doi:10.1007/s10554-015-0792-x · Cited by 58
Emmert, M. Y., Weber, B., Behr, L., Sammut, S., Frauenfelder, T., Wolint, P., Scherman, J., Béttex, D., Grünenfelder, J., Falk, V., et al. (2013) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezt243 · Cited by 58
Stangl, V., Baldenhofer, G., Laule, M., Baumann, G., & STANGL, K. (2014) · Journal of Interventional Cardiology · doi:10.1111/joic.12150 · Cited by 58
Vaquerizo, B., Spaziano, M., Ali, J. A., Mylote, D., Thériault-Lauzier, P., Alfagih, R., Martucci, G. J., Buithieu, J., & Piazza, N. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jev238 · Cited by 58
Arnold, S. V., Spertus, J. A., Vemulapalli, S., Dai, D., O’Brien, S. M., Baron, S. J., Kirtane, A. J., Mack, M. J., Green, P., Reynolds, M. R., et al. (2015) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.115.002875 · Cited by 58
Self-citationClinical Outcomes and Imaging Findings in Women Undergoing TAVR
Naoum, C., Blanke, P., Dvir, D., Pîbarot, P., Humphries, K. H., Webb, J. G., & Leipsic, J. A. (2016) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2016.02.009 · Cited by 58
Self-citationVillablanca, P. A., Mathew, V., Thourani, V. H., Rodés‐Cabau, J., Bangalore, S., Makkiya, M., Vlismas, P. P., Briceno, D. F., Slovut, D. P., Taub, C. C., et al. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.10.003 · Cited by 58
Self-citationBen‐Shoshan, J., Konigstein, M., Zahler, D., Margolis, G., Chorin, E., Steinvil, A., Arbel, Y., Aviram, G., Granot, Y. N., Barkagan, M., et al. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2016.09.030 · Cited by 58
Toutouzas, K. P., Benetos, G., Voudris, V., Drakopoulou, M. I., Stathogiannis, K. E., Latsios, G., Synetos, A. G., Antonopoulos, A. S., Kosmas, I., Iakovou, I. P., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.02.005 · Cited by 58
Brain Injury After Transcatheter Replacement of Bicuspid Versus Tricuspid Aortic Valves
Fan, J., Fang, X., Liu, C., Zhu, G., Hou, C. R., Jiang, J., Lin, X., Wang, L., He, Y., Zhu, Q., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.09.605 · Cited by 58
Self-citationManoharan, G., Linke, A. H.-P., Moellmann, H., Redwood, S. R., Frerker, C., Kovac, J., & Walther, T. (2016) · EuroIntervention · doi:10.4244/eijv12i6a125 · Cited by 57
Chen, S., Chau, K. H.-Y., & Nazif, T. M. (2020) · Annals of Cardiothoracic Surgery · doi:10.21037/acs-2020-av-23 · Cited by 57
Chinese Guidelines for the Diagnosis and Treatment of Heart Failure 2024
ZHANG, S.-Y. (2025) · 老年心脏病学杂志:英文版 · doi:10.26599/1671-5411.2025.03.002 · Cited by 60
Lehmkuhl, L., Foldyna, B., von ASPERN, K., Lücke, C., Grothoff, M., Nitzsche, S., Kempfert, J., Haensig, M., Rastan, A. J., Walther, T., et al. (2012) · International journal of cardiac imaging · doi:10.1007/s10554-012-0123-4 · Cited by 57
Mechanisms and management of TAVR-related complications
Fassa, A.-A., Himbert, D., & Vahanian, A. S. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.156 · Cited by 57
Use of the Hybrid Operating Room in Cardiovascular Medicine
Kaneko, T., & Davidson, M. (2014) · Circulation · doi:10.1161/circulationaha.114.006510 · Cited by 57
Szelkowski, L. A., Puri, N. K., Singh, R., & Massimiano, P. S. (2014) · Current Problems in Surgery · doi:10.1067/j.cpsurg.2014.10.001 · Cited by 57
Systematic review of the cost-effectiveness of transcatheter aortic valve implantation
Indraratna, P., Ang, S. C., Gada, H., Yan, T. D., Manganas, C., Bannon, P. G., & Cao, C. Q. (2013) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2013.10.023 · Cited by 57
Costs for Surgical Aortic Valve Replacement According to Preoperative Risk Categories
Osnabrugge, R. L. J., Speir, A. M., Head, S. J., Fonner, C. E., Fonner, E., Ailawadi, G., Kappetein, A. P., & Rich, J. B. (2013) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2013.04.038 · Cited by 57
The 100 most cited publications in cardiac surgery: a bibliometric analysis
O'Sullivan, K., Kelly, J. C., & Hurley, J. P. (2014) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-014-1193-1 · Cited by 59
Feuchtner, G. M., Plank, F., Bartel, T., Mueller, S., Leipsic, J. A., Schachner, T., Müller, L. C., Friedrich, G. J., Klauser, A. S., Grimm, M., et al. (2013) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2013.06.049 · Cited by 57
Al-Lamee, R. K., Broyd, C., Parker, J., Davies, J. E., Mayet, J., Sutaria, N., Ariff, B., Unsworth, B., Cousins, J., Bicknell, C. D., et al. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.10.024 · Cited by 57
Reed, G. W., Masri, A., Griffin, B. P., Kapadia, S. R., Ellis, S. G., & Desai, M. Y. (2016) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.115.003483 · Cited by 57
Self-citationDahya, V., Xiao, J., Prado, C. M. M., Burroughs, P., McGee, D., Silva, A. C., Hurt, J. E., Mohamed, S. G., Noel, T. E., & Batchelor, W. (2016) · American Heart Journal · doi:10.1016/j.ahj.2016.08.016 · Cited by 59
Gomes, B., Geis, N. A., Chorianopoulos, E., Meder, B., Leuschner, F., Katus, H. A., & Bekeredjian, R. (2016) · Journal of Interventional Cardiology · doi:10.1111/joic.12356 · Cited by 57
Liao, Y., Zhao, Z., Wei, X., Xu, Y., Zuo, Z., Li, Y., Zheng, M., Feng, Y., & Chen, M. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26912 · Cited by 57
Lv, W., Li, S., Liao, Y., Zhao, Z., Che, G., Chen, M., & Feng, Y. (2017) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivx191 · Cited by 57
D’Ascenzo, F., Benedetto, U., Bianco, M., Conrotto, F., Moretti, C., D’Onofrio, A., Agrifoglio, M., Colombo, A., Ribichini, F. L., Tarantini, G., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-17-00198 · Cited by 57
Echocardiographic Imaging for Transcatheter Aortic Valve Replacement
Hahn, R. T., Nicoara, A., Kapadia, S. R., Svensson, L. G., & Martin, R. P. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.10.022 · Cited by 57
Self-citationLavon, K., Marom, G., Bianchi, M., Halevi, R., Hamdan, A., Morany, A., Raanani, E., Bluestein, D., & Haj-Ali, R. M. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02012-y · Cited by 57
Factors in ProGlide® Vascular Closure Failure in Sheath Arteriotomies Greater than 16 French
Chen, I., Lee, T.-H., Chen, P., Shih, C.-C., & Chang, H.-H. (2019) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2019.03.037 · Cited by 57
Fairbairn, T. A., Meads, D. M., Mather, A. N., Motwani, M., Pavitt, S. H., Plein, S., Blackman, D. J., & Greenwood, J. P. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.035 · Cited by 57
Petronio, A. S., Giannini, C., Carlo, M. D., Bedogni, F., Colombo, A., Tamburino, C., Klugmann, S., Poli, A., Guarracino, F., Barbanti, M., et al. (2016) · EuroIntervention · doi:10.4244/eijy15m03_05 · Cited by 56
Guerrero, M. E., Greenbaum, A. B., & O’Neill, W. W. (2014) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25441 · Cited by 56
Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve
Xuan, Y., Krishnan, K., Ye, J., Dvir, D., Guccione, J. M., Ge, L., & Tseng, E. E. (2016) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2016.12.016 · Cited by 56
Infective endocarditis – A review of current therapy and future challenges
Rezar, R., Lichtenauer, M., Haar, M., Hödl, G., Kern, J. M., Zhou, Z., Wuppinger, T., Kraus, J., Strohmer, B., Hoppe, U. C., et al. (2020) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2020.10.007 · Cited by 56
Kobrin, D. M., McCarthy, F. H., Herrmann, H. C., Anwaruddin, S., KOBRIN, S. M., Szeto, W. Y., Bavaria, J. E., Groeneveld, P. W., & Desai, N. D. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.05.039 · Cited by 56
Self-citationMyocardial Injury After Transaortic Versus Transapical Transcatheter Aortic Valve Replacement
Ribeiro, H. B., Dahou, A., Ureña, M., Carrasco, J. L., Mohammadi, S., Doyle, D., Ven, F. L., Allende, R., Amat-Santos, I. J., Paradis, J., et al. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.01.029 · Cited by 56
Review of Reported Causes of Device Embolization Following Trans-Catheter Aortic Valve Implantation
Ibebuogu, U. N., Giri, S., Bolorunduro, O. B., Tartara, P., Kar, S., Holmes, D. R., & Alli, O. O. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.03.024 · Cited by 56
Wijeysundera, H. C., Wong, W. W. L., Bennell, M. C., Fremes, S. E., Radhakrishnan, S., Peterson, M. D., & Ko, D. T. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.03.009 · Cited by 56
Caceres, M., Braud, R. L., & Roselli, E. E. (2012) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2011.10.056 · Cited by 56
Dewey, T. M., Bowers, B. S., Thourani, V. H., Babaliaros, V. C., Smith, C. R., Leon, M. B., Svensson, L. G., Tuzcu, E. M., Miller, D. C., Teirstein, P. S., et al. (2013) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2013.05.093 · Cited by 56
Self-citationPasseri, J. J., Elmariah, S., Xu, K., Inglessis, I., Baker, J. N., Alu, M. C., Kodali, S., Leon, M. B., Svensson, L. G., Pîbarot, P., et al. (2015) · Heart · doi:10.1136/heartjnl-2014-306737 · Cited by 56
Self-citationThyregod, H. G. H., Søndergaard, L., Ihlemann, N., Franzen, O. W., Andersen, L. W., Hansen, P. B., Olsen, P. S., Nissen, H., Winkel, P., Gluud, C. N., et al. (2013) · Trials · doi:10.1186/1745-6215-14-11 · Cited by 56
Little, S. H., Oh, J. K., Gillam, L. D., Sengupta, P. P., Orsinelli, D. A., Cavalcante, J. L., Chang, J. D., Adams, D. H., Zorn, G. L., Pollak, A. W., et al. (2016) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.115.003426 · Cited by 56
Bureau, M.-L., Liuu, É., Christiaens, L. P., Pilotto, A., Mergy, J., Bellarbre, F., Ingrand, P., Paccalin, M., Cruz-Jentoft, A. J., Maggi, S., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.02.048 · Cited by 56
Sohn, S. H., Jang, M., Hwang, H. Y., & Kim, K. H. (2018) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2018.01.084 · Cited by 56
Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement
Chakravarty, T., Patel, A., Kapadia, S. R., Raschpichler, M., Smalling, R. W., Szeto, W. Y., Abramowitz, Y., Cheng, W., Douglas, P. S., Hahn, R. T., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.06.058 · Cited by 56
Self-citationYang, F., Xu, L., Kuang, D., Ge, Y., Guo, G., & Wang, Y. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.128244 · Cited by 56
Tran, K. T., Cimon, K., Severn, M., Pessoa-Silva, C. L., & Conly, J. M. (2013) · Europe PMC (PubMed Central) · Cited by 55
Möllmann, H., Bestehorn, K. P., Bestehorn, M., Papoutsis, K., Fleck, E., Ertl, G., Kück, K., & Hamm, C. W. (2016) · Clinical Research in Cardiology · doi:10.1007/s00392-016-0962-4 · Cited by 55
Witberg, G., Lador, A., Yahav, D., & Kornowski, R. (2018) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27518 · Cited by 55
Luraghi, G., Matas, J. F. R., Beretta, M., Chiozzi, N., Iannetti, L., & Migliavacca, F. (2020) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2020.1817409 · Cited by 55
Robotic aortic valve replacement
Badhwar, V., Wei, L. M., Cook, C. C. H., Hayanga, J. W. A., Daggubati, R. B., Sengupta, P. P., & Rankin, J. S. (2020) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2020.10.078 · Cited by 55
Transcatheter aortic valve implantation and cerebrovascular events: the current state of the art
Hynes, B. G., & Rodés‐Cabau, J. (2012) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2012.06477.x · Cited by 55
Hybrid Imaging During Transcatheter Structural Heart Interventions
Biaggi, P., Fernández‐Golfín, C., Hahn, R. T., & Corti, R. (2015) · Current Cardiovascular Imaging Reports · doi:10.1007/s12410-015-9349-6 · Cited by 55
Atrial Fibrillation, Stroke, and Mortality Rates After Transcatheter Aortic Valve Implantation
Yankelson, L., Steinvil, A., Gershovitz, L., Leshem‐Rubinow, E., Furer, A., Viskin, S., Keren, G., Banai, S., & Finkelstein, A. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.09.025 · Cited by 55
Seiffert, M., Conradi, L., Baldus, S. E., Schirmer, J. M., Blankenberg, S., Reichenspurner, H. C., Diemert, P., & Treede, H. (2013) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezt032 · Cited by 55
Expanding TAVI to Low and Intermediate Risk Patients
Voigtländer, L., & Seiffert, M. (2018) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2018.00092 · Cited by 55
Kumar, A., Sato, K., Narayanswami, J., Banerjee, K., Andress, K., Lokhande, C., Mohananey, D., Anumandla, A. K. R., Khan, A. R., Sawant, A. C., et al. (2018) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.118.006664 · Cited by 55
Self-citationThe Evolving Management of Aortic Valve Disease: 5-Year Trends in SAVR, TAVR, and Medical Therapy
Goldsweig, A. M., Tak, H. J., Chen, L., Aronow, H. D., Shah, B., Kolte, D. S., Velagapudi, P., Desai, N. R., Szerlip, M., & Abbott, J. D. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.05.044 · Cited by 55
Aguado, B. A., Schuetze, K. B., Grim, J. C., Walker, C. J., Cox, A. C., Ceccato, T. L., Tan, A. C., Sucharov, C. C., Leinwand, L. A., Taylor, M. R. G., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav3233 · Cited by 55
Metadata
- Authors
- Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., Williams, M., Dewey, T., Kapadia, S., Babaliaros, V., Thourani, V. H., Corso, P., Pichard, A. D., Bavaria, J. E., Herrmann, H. C., Akin, J. J., Anderson, W. N., Wang, D., & Pocock, S. J.
- Affiliations
- NewYork–Presbyterian Hospital (US)
- Baylor Scott & White Health (US)
- Stanford Medicine (US)
- Cleveland Clinic (US)
- University of British Columbia (CA)
- Cedars-Sinai Medical Center (US)
- Medical City Dallas Hospital (US)
- Emory University (US)
- MedStar Washington Hospital Center (US)
- Hospital of the University of Pennsylvania (US)
- Edwards Lifesciences (United States) (US)
- London School of Hygiene & Tropical Medicine (GB)
- ORCID
- Smith, Craig R.
- Leon, Martin B.
- Mack, Michael J.
- Miller, D. Craig
- Moses, Jeffrey W.
- Svensson, Lars G.
- Tuzcu, E. Murat
- Webb, John G.
- Fontana, Gregory P.
- Makkar, Raj R.
- Williams, Mathew
- Kapadia, Samir
- Babaliaros, Vasilis
- Thourani, Vinod H.
- Bavaria, Joseph E.
- Herrmann, Howard C.
- Anderson, William N.
- Wang, Duolao
- Pocock, Stuart J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2011-06-09
- Volume
- 364
- Issue
- 23
- Pages
- 2187-2198
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2165258820
- Cited by
- 6,345
- References
- 44
- Citations by year
- 2026: 194 · 2025: 239 · 2024: 315 · 2023: 331 · 2022: 340 · 2021: 396 · 2020: 457 · 2019: 507 · 2018: 503 · 2017: 545 · 2016: 533 · 2015: 502 · 2014: 455 · 2013: 484 · 2012: 449
- FWCI
- 322.18
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- LSHTM Research Online (London School of Hygiene and Tropical Medicine) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- transcatheter aortic valve implantation, surgical aortic valve replacement, severe aortic stenosis, high-risk patients, transapical approach, transfemoral access, non-inferiority, mortality, stroke, vascular complications, hemorrhage, atrial fibrillation, periprocedural risk, symptom improvement, randomized trial comparison
- MeSH terms
- Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Stenosis, Cardiovascular Diseases, Catheterization, Female, Cardiac Catheterization, Humans, Male, Postoperative Complications, Risk Factors, Heart Valve Prosthesis Implantation, Stroke, Intention to Treat Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review