Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 707

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days

Open access
Lamy, André, Devereaux, P.J., Prabhakaran, Dorairaj, Taggart, David P., Hu, Shengshou, Paolasso, Ernesto, Straka, Zbynek, Piegas, Leopoldo S., Akar, Ahmet Ruchan, Jain, Anil R., Noiseux, Nicolas, Padmanabhan, Chandrasekar, Bahamondes, Juan-Carlos, Novick, Richard J., Vaijyanath, Prashant, Reddy, Sukesh, Tao, Liang, Olavegogeascoechea, Pablo A., Airan, Balram, Sulling, Toomas-Andres, Whitlock, Richard P., Ou, Yongning, Ng, Jennifer, Chrolavicius, Susan, Yusuf, Salim·2012·New England Journal of Medicine

Abstract

BACKGROUND: The relative benefits and risks of performing coronary-artery bypass grafting (CABG) with a beating-heart technique (off-pump CABG), as compared with cardiopulmonary bypass (on-pump CABG), are not clearly established. METHODS: At 79 centers in 19 countries, we randomly assigned 4752 patients in whom CABG was planned to undergo the procedure off-pump or on-pump. The first coprimary outcome was a composite of death, nonfatal stroke, nonfatal myocardial infarction, or new renal failure requiring dialysis at 30 days after randomization. RESULTS: There was no significant difference in the rate of the primary composite outcome between off-pump and on-pump CABG (9.8% vs. 10.3%; hazard ratio for the off-pump group, 0.95; 95% confidence interval [CI], 0.79 to 1.14; P=0.59) or in any of its individual components. The use of off-pump CABG, as compared with on-pump CABG, significantly reduced the rates of blood-product transfusion (50.7% vs. 63.3%; relative risk, 0.80; 95% CI, 0.75 to 0.85; P<0.001), reoperation for perioperative bleeding (1.4% vs. 2.4%; relative risk, 0.61; 95% CI, 0.40 to 0.93; P=0.02), acute kidney injury (28.0% vs. 32.1%; relative risk, 0.87; 95% CI, 0.80 to 0.96; P=0.01), and respiratory complications (5.9% vs. 7.5%; relative risk, 0.79; 95% CI, 0.63 to 0.98; P=0.03) but increased the rate of early repeat revascularizations (0.7% vs. 0.2%; hazard ratio, 4.01; 95% CI, 1.34 to 12.0; P=0.01). CONCLUSIONS: There was no significant difference between off-pump and on-pump CABG with respect to the 30-day rate of death, myocardial infarction, stroke, or renal failure requiring dialysis. The use of off-pump CABG resulted in reduced rates of transfusion, reoperation for perioperative bleeding, respiratory complications, and acute kidney injury but also resulted in an increased risk of early revascularization. (Funded by the Canadian Institutes of Health Research; CORONARY ClinicalTrials.gov number, NCT00463294.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1200388

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 707

Metadata

Authors
Lamy, A., Devereaux, P. J., Prabhakaran, D., Taggart, D. P., Hu, S., Paolasso, E., Straka, Z., Piegas, L. S., Akar, A. R., Jain, A. R., Noiseux, N., Padmanabhan, C., Bahamondes, J.-C., Novick, R. J., Vaijyanath, P., Reddy, S., Tao, L., Olavegogeascoechea, P. A., Airan, B., Sulling, T.-A., Whitlock, R. P., Ou, Y., Ng, J., Chrolavicius, S., & Yusuf, S.
Venue
New England Journal of Medicine
Published
2012-04-19
Volume
366
Issue
16
Pages
1489-1497
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2132547422
Cited by
707
References
1
FWCI
75.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days. https://app.cochat.ai/papers/10.1056/nejmoa1200388
The paper
Lamy, A., Devereaux, P. J., Prabhakaran, D., Taggart, D. P., Hu, S., Paolasso, E., Straka, Z., Piegas, L. S., Akar, A. R., Jain, A. R., Noiseux, N., Padmanabhan, C., Bahamondes, J.-C., Novick, R. J., Vaijyanath, P., Reddy, S., Tao, L., Olavegogeascoechea, P. A., Airan, B., . . . Yusuf, S. (2012). Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1200388

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.