Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days
Open accessAbstract
BACKGROUND: The relative benefits and risks of performing coronary-artery bypass grafting (CABG) with a beating-heart technique (off-pump CABG), as compared with cardiopulmonary bypass (on-pump CABG), are not clearly established. METHODS: At 79 centers in 19 countries, we randomly assigned 4752 patients in whom CABG was planned to undergo the procedure off-pump or on-pump. The first coprimary outcome was a composite of death, nonfatal stroke, nonfatal myocardial infarction, or new renal failure requiring dialysis at 30 days after randomization. RESULTS: There was no significant difference in the rate of the primary composite outcome between off-pump and on-pump CABG (9.8% vs. 10.3%; hazard ratio for the off-pump group, 0.95; 95% confidence interval [CI], 0.79 to 1.14; P=0.59) or in any of its individual components. The use of off-pump CABG, as compared with on-pump CABG, significantly reduced the rates of blood-product transfusion (50.7% vs. 63.3%; relative risk, 0.80; 95% CI, 0.75 to 0.85; P<0.001), reoperation for perioperative bleeding (1.4% vs. 2.4%; relative risk, 0.61; 95% CI, 0.40 to 0.93; P=0.02), acute kidney injury (28.0% vs. 32.1%; relative risk, 0.87; 95% CI, 0.80 to 0.96; P=0.01), and respiratory complications (5.9% vs. 7.5%; relative risk, 0.79; 95% CI, 0.63 to 0.98; P=0.03) but increased the rate of early repeat revascularizations (0.7% vs. 0.2%; hazard ratio, 4.01; 95% CI, 1.34 to 12.0; P=0.01). CONCLUSIONS: There was no significant difference between off-pump and on-pump CABG with respect to the 30-day rate of death, myocardial infarction, stroke, or renal failure requiring dialysis. The use of off-pump CABG resulted in reduced rates of transfusion, reoperation for perioperative bleeding, respiratory complications, and acute kidney injury but also resulted in an increased risk of early revascularization. (Funded by the Canadian Institutes of Health Research; CORONARY ClinicalTrials.gov number, NCT00463294.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Need for expertise based randomised controlled trials
Devereaux, P. J., Bhandari, M., Clarke, M., Montori, V. M., Cook, D. J., Yusuf, S., Sackett, D. L., Cinà, C. S., Walter, S. D., Haynes, B., et al. (2005) · BMJ · doi:10.1136/bmj.330.7482.88 · Cited by 427
Self-citation
Cited by
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Self-citationAboyans, V., Ricco, J.-B., Bartelink, M.-L. E. L., Björck, M., Brodmann, M., Cohnert, T., Collet, J.-P., Czerny, M., De Carlo, M., Debus, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx095 · Cited by 3,293
2018 ESC/EACTS Guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · EuroIntervention · doi:10.4244/eijy19m01_01 · Cited by 1,259
Metadata
- Authors
- Lamy, A., Devereaux, P. J., Prabhakaran, D., Taggart, D. P., Hu, S., Paolasso, E., Straka, Z., Piegas, L. S., Akar, A. R., Jain, A. R., Noiseux, N., Padmanabhan, C., Bahamondes, J.-C., Novick, R. J., Vaijyanath, P., Reddy, S., Tao, L., Olavegogeascoechea, P. A., Airan, B., Sulling, T.-A., Whitlock, R. P., Ou, Y., Ng, J., Chrolavicius, S., & Yusuf, S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2012-04-19
- Volume
- 366
- Issue
- 16
- Pages
- 1489-1497
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2132547422
- Cited by
- 707
- References
- 1
- FWCI
- 75.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days. https://app.cochat.ai/papers/10.1056/nejmoa1200388
- The paper
- Lamy, A., Devereaux, P. J., Prabhakaran, D., Taggart, D. P., Hu, S., Paolasso, E., Straka, Z., Piegas, L. S., Akar, A. R., Jain, A. R., Noiseux, N., Padmanabhan, C., Bahamondes, J.-C., Novick, R. J., Vaijyanath, P., Reddy, S., Tao, L., Olavegogeascoechea, P. A., Airan, B., . . . Yusuf, S. (2012). Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1200388
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.