CoChat

Von Willebrand Factor Multimers during Transcatheter Aortic-Valve Replacement

Van Belle, Eric, Rauch, Antoine, Vincent, Flavien, Robin, Emmanuel, Kibler, Marion, Labreuche, Julien, Jeanpierre, Emmanuelle, Levade, Marie, Hurt, Christopher, Rousse, Natacha, Dally, Jean-Baptiste, Debry, Nicolas, Dallongeville, Jean, Vincentelli, Andre, Delhaye, Cedric, Auffray, Jean-Luc, Juthier, Francis, Schurtz, Guillaume, Lemesle, Gilles, Caspar, Thibault, Morel, Olivier, Dumonteil, Nicolas, Duhamel, Alain, Paris, Camille, Dupont-Prado, Annabelle, Legendre, Paulette, Mouquet, Frederic, Marchant, Berenice, Hermoire, Sylvie, Corseaux, Delphine, Moussa, Karim, Manchuelle, Aurelie, Bauchart, Jean-Jacques, Loobuyck, Valentin, Caron, Claudine, Zawadzki, Christophe, Leroy, Fabrice, Bodart, Jean-Christophe, Staels, Bart, Goudemand, Jenny, Lenting, Peter J., Susen, Sophie · 2016 · New England Journal of Medicine
Cited by 159

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Postprocedural aortic regurgitation occurs in 10 to 20% of patients undergoing transcatheter aortic-valve replacement (TAVR) for aortic stenosis. We hypothesized that assessment of defects in high-molecular-weight (HMW) multimers of von Willebrand factor or point-of-care assessment of hemostasis could be used to monitor aortic regurgitation during TAVR. METHODS: We enrolled 183 patients undergoing TAVR. Patients with aortic regurgitation after the initial implantation, as identified by means of transesophageal echocardiography, underwent additional balloon dilation to correct aortic regurgitation. HMW multimers and the closure time with adenosine diphosphate (CT-ADP), a point-of-care measure of hemostasis, were assessed at baseline and 5 minutes after each step of the procedure. Mortality was evaluated at 1 year. A second cohort (201 patients) was studied to validate the use of CT-ADP in order to identify patients with aortic regurgitation. RESULTS: After the initial implantation, HMW multimers normalized in patients without aortic regurgitation (137 patients). Among the 46 patients with aortic regurgitation, normalization occurred in 20 patients in whom additional balloon dilation was successful but did not occur in the 26 patients with persistent aortic regurgitation. A similar sequence of changes was observed with CT-ADP. A CT-ADP value of more than 180 seconds had sensitivity, specificity, and negative predictive value of 92.3%, 92.4%, and 98.6%, respectively, for aortic regurgitation, with similar results in the validation cohort. Multivariable analyses showed that the values for HMW multimers and CT-ADP at the end of TAVR were each associated with mortality at 1 year. CONCLUSIONS: The presence of HMW-multimer defects and a high value for a point-of-care hemostatic test, the CT-ADP, were each predictive of the presence of aortic regurgitation after TAVR and were associated with higher mortality 1 year after the procedure. (Funded by Lille 2 University and others; ClinicalTrials.gov number, NCT02628509.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1505643

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 159

Metadata

Authors
Van Belle, E., Rauch, A., Vincent, F., Robin, E., Kibler, M., Labreuche, J., Jeanpierre, E., Levade, M., Hurt, C., Rousse, N., Dally, J.-B., Debry, N., Dallongeville, J., Vincentelli, A., Delhaye, C., Auffray, J.-L., Juthier, F., Schurtz, G., Lemesle, G., Caspar, T., Morel, O., Dumonteil, N., Duhamel, A., Paris, C., Dupont-Prado, A., Legendre, P., Mouquet, F., Marchant, B., Hermoire, S., Corseaux, D., Moussa, K., Manchuelle, A., Bauchart, J.-J., Loobuyck, V., Caron, C., Zawadzki, C., Leroy, F., Bodart, J.-C., Staels, B., Goudemand, J., Lenting, P. J., & Susen, S.
Venue
New England Journal of Medicine
Published
2016-07-28
Volume
375
Issue
4
Pages
335-344
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2479787736
Cited by
159
References
3
FWCI
19.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Von Willebrand Factor Multimers during Transcatheter Aortic-Valve Replacement. https://app.cochat.ai/papers/10.1056/nejmoa1505643
The paper
Van Belle, E., Rauch, A., Vincent, F., Robin, E., Kibler, M., Labreuche, J., Jeanpierre, E., Levade, M., Hurt, C., Rousse, N., Dally, J.-B., Debry, N., Dallongeville, J., Vincentelli, A., Delhaye, C., Auffray, J.-L., Juthier, F., Schurtz, G., Lemesle, G., . . . Susen, S. (2016). Von Willebrand Factor Multimers during Transcatheter Aortic-Valve Replacement. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1505643

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.