Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
AIM: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) remains uncertain. In this analysis, we sought to evaluate the impact of varying degrees of PVR on both mortality and changes in ventricular geometry and function. METHODS AND RESULTS: Clinical and echocardiographic outcomes of patients who underwent TAVR from the randomized cohorts and continued access registries in the PARTNER trial were analysed after stratifying by severity of post-implant PVR, which was graded as none/trace in 52.9% (n = 1288), mild in 38.0% (n = 925), and moderate/severe in 9.1% (n = 221). There were significant differences in baseline clinical and echocardiographic characteristics. After TAVR, all the patients demonstrated increase in left ventricular (LV) function and reduction in the LV mass index, although the magnitude of mass regression was lower in the moderate/severe PVR group. The 30-day mortality (3.1 vs. 3.4 vs. 4.5%, P = 0.56) and stroke (3.4 vs. 3.7 vs. 2.3%, P = 0.59) were similar in all groups (none/trace, mild, and moderate/severe). At 1 year, there was increased all-cause mortality (15.9 vs. 22.2 vs. 35.1%, P < 0.0001), cardiac mortality (6.1 vs. 7.4% vs. 16.3%, P < 0.0001) and re-hospitalization (14.4 vs. 23.0 vs. 31.3%, P < 0.0001) with worsening PVR. A multivariable analysis indicated that the presence of moderate/severe PVR (HR: 2.18, 95% CI: 1.57-3.02, P < 0.0001) or mild PVR (HR: 1.37, 95% CI: 1.14-1.90, P = 0.012) was associated with higher late mortality. CONCLUSION: Differences in baseline characteristics in patients with increasing severities of PVR may increase the risk of this complication. Despite these differences, multivariable analysis demonstrated that both mild and moderate/severe PVR predicted higher 1-year mortality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The association between moderate or severe paravalvular aortic regurgitation and increased mortality has been clearly established”
From Calcific aortic stenosis (2016) · cites this paper as [237]
In the citing paper
“with some studies even suggesting that this adverse association extends to mild regurgitation235;237;238.”
From Calcific aortic stenosis (2016) · cites this paper as [237]
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationZoghbi, W. A., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Kraft, C. D., Levine, R. A., Nihoyannopoulos, P., Otto, C. M., Quinones, M. A., Rakowski, H., et al. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00335-3 · Cited by 4,044
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationTwo-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationUpdated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Self-citationTamburino, C., Capodanno, D., Ramondo, A., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,124
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Research works printed but not linked: 1
- 2012, New England Journal of Medicine, 366, 1686, 10.1056/nejmoa1200384 · DOI · Paper page
Cited by
Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Self-citation2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Thourani, V. H., Kodali, S., Makkar, R. R., Herrmann, H. C., Williams, M., Babaliaros, V., Smalling, R., Lim, S., Malaisrie, S. C., Kapadia, S., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30073-3 · Cited by 1,028
Self-citationLindman, B. R., Clavel, M.-A., Mathieu, P., Iung, B., Lancellotti, P., Otto, C. M., & Pibarot, P. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.6 · Cited by 982
Five-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement
Makkar, R. R., Thourani, V. H., Mack, M. J., Kodali, S. K., Kapadia, S., Webb, J. G., Yoon, S.-H., Trento, A., Svensson, L. G., Herrmann, H. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1910555 · Cited by 832
Self-citation
Metadata
- Authors
- Kodali, S., Pibarot, P., Douglas, P. S., Williams, M., Xu, K., Thourani, V., Rihal, C. S., Zajarias, A., Doshi, D., Davidson, M., Tuzcu, E. M., Stewart, W., Weissman, N. J., Svensson, L., Greason, K., Maniar, H., Mack, M., Anwaruddin, S., Leon, M. B., & Hahn, R. T.
- Affiliations
- NewYork–Presbyterian Hospital (US)
- Duke Clinical Research Institute (US)
- Cardiovascular Research Foundation (US)
- Emory University (US)
- Mayo Clinic (US)
- Brigham and Women's Hospital (US)
- Cleveland Clinic (US)
- MedStar Health Research Institute (US)
- Washington University in St. Louis (US)
- Hospital of the University of Pennsylvania (US)
- Corresponding author
- Kodali, S.
- ORCID
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-10-01
- Volume
- 36
- Issue
- 7
- Pages
- 449-456
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2081463532
- Cited by
- 446
- References
- 40
- Citations by year
- 2026: 14 · 2025: 18 · 2024: 17 · 2023: 29 · 2022: 33 · 2021: 31 · 2020: 48 · 2019: 45 · 2018: 49 · 2017: 67 · 2016: 60 · 2015: 31 · 2014: 3
- FWCI
- 36.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- Corpus Université Laval (Université Laval) (submittedVersion)
- Funders
- Edwards Lifesciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- paravalvular leak, transcatheter aortic valve implantation, Edwards SAPIEN valve, PARTNER trial, aortic stenosis, mortality, left ventricular mass, ventricular geometry, hospital readmission, stroke, echocardiographic assessment, risk stratification, transcatheter versus surgical aortic valve replacement, left ventricular function
- MeSH terms
- Aged, 80 and over, Aortic Valve Insufficiency, Aortic Valve Stenosis, Echocardiography, Female, Humans, Male, Mitral Valve Insufficiency, Organ Size, Reoperation, Heart Valve Prolapse, Treatment Outcome, Transcatheter Aortic Valve Replacement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes. https://app.cochat.ai/papers/10.1093/eurheartj/ehu384
- The paper
- Kodali, S., Pibarot, P., Douglas, P. S., Williams, M., Xu, K., Thourani, V., Rihal, C. S., Zajarias, A., Doshi, D., Davidson, M., Tuzcu, E. M., Stewart, W., Weissman, N. J., Svensson, L., Greason, K., Maniar, H., Mack, M., Anwaruddin, S., Leon, M. B., & Hahn, R. T. (2015). Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes. European Heart Journal. https://doi.org/10.1093/eurheartj/ehu384
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.