Patent Foramen Ovale Closure or Antiplatelet Therapy for Cryptogenic Stroke

Søndergaard, Lars, Kasner, Scott E., Rhodes, John F., Andersen, Grethe, Iversen, Helle K., Nielsen-Kudsk, Jens E., Settergren, Magnus, Sjöstrand, Christina, Roine, Risto O., Hildick-Smith, David, Spence, J. David, Thomassen, Lars · 2017 · New England Journal of Medicine

Abstract

BACKGROUND: The efficacy of closure of a patent foramen ovale (PFO) in the prevention of recurrent stroke after cryptogenic stroke is uncertain. We investigated the effect of PFO closure combined with antiplatelet therapy versus antiplatelet therapy alone on the risks of recurrent stroke and new brain infarctions. METHODS: In this multinational trial involving patients with a PFO who had had a cryptogenic stroke, we randomly assigned patients, in a 2:1 ratio, to undergo PFO closure plus antiplatelet therapy (PFO closure group) or to receive antiplatelet therapy alone (antiplatelet-only group). Imaging of the brain was performed at the baseline screening and at 24 months. The coprimary end points were freedom from clinical evidence of ischemic stroke (reported here as the percentage of patients who had a recurrence of stroke) through at least 24 months after randomization and the 24-month incidence of new brain infarction, which was a composite of clinical ischemic stroke or silent brain infarction detected on imaging. RESULTS: We enrolled 664 patients (mean age, 45.2 years), of whom 81% had moderate or large interatrial shunts. During a median follow-up of 3.2 years, clinical ischemic stroke occurred in 6 of 441 patients (1.4%) in the PFO closure group and in 12 of 223 patients (5.4%) in the antiplatelet-only group (hazard ratio, 0.23; 95% confidence interval [CI], 0.09 to 0.62; P=0.002). The incidence of new brain infarctions was significantly lower in the PFO closure group than in the antiplatelet-only group (22 patients [5.7%] vs. 20 patients [11.3%]; relative risk, 0.51; 95% CI, 0.29 to 0.91; P=0.04), but the incidence of silent brain infarction did not differ significantly between the study groups (P=0.97). Serious adverse events occurred in 23.1% of the patients in the PFO closure group and in 27.8% of the patients in the antiplatelet-only group (P=0.22). Serious device-related adverse events occurred in 6 patients (1.4%) in the PFO closure group, and atrial fibrillation occurred in 29 patients (6.6%) after PFO closure. CONCLUSIONS: Among patients with a PFO who had had a cryptogenic stroke, the risk of subsequent ischemic stroke was lower among those assigned to PFO closure combined with antiplatelet therapy than among those assigned to antiplatelet therapy alone; however, PFO closure was associated with higher rates of device complications and atrial fibrillation. (Funded by W.L. Gore and Associates; Gore REDUCE ClinicalTrials.gov number, NCT00738894 .).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1707404

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 1,137

Metadata

Authors
Søndergaard, L., Kasner, S. E., Rhodes, J. F., Andersen, G., Iversen, H. K., Nielsen-Kudsk, J. E., Settergren, M., Sjöstrand, C., Roine, R. O., Hildick-Smith, D., Spence, J. D., & Thomassen, L.
Venue
New England Journal of Medicine
Published
2017-09-14
Volume
377
Issue
11
Pages
1033-1042
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2755497194
Cited by
1,137
References
23
FWCI
97.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.