Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 637

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

An index to identify stroke-related vs incidental patent foramen ovale in cryptogenic stroke

Open access
Kent, David M., Ruthazer, Robin, Weimar, Christian, Mas, Jean-Louis, Serena, Joaquín, Homma, Shunichi, Di Angelantonio, Emanuele, Di Tullio, Marco R., Lutz, Jennifer S., Elkind, Mitchell S.V., Griffith, John, Jaigobin, Cheryl, Mattle, Heinrich P., Michel, Patrik, Mono, Marie-Louise, Nedeltchev, Krassen, Papetti, Federica, Thaler, David E.·2013·Neurology

Abstract

OBJECTIVE: We aimed to create an index to stratify cryptogenic stroke (CS) patients with patent foramen ovale (PFO) by their likelihood that the stroke was related to their PFO. METHODS: Using data from 12 component studies, we used generalized linear mixed models to predict the presence of PFO among patients with CS, and derive a simple index to stratify patients with CS. We estimated the stratum-specific PFO-attributable fraction and stratum-specific stroke/TIA recurrence rates. RESULTS: Variables associated with a PFO in CS patients included younger age, the presence of a cortical stroke on neuroimaging, and the absence of these factors: diabetes, hypertension, smoking, and prior stroke or TIA. The 10-point Risk of Paradoxical Embolism score is calculated from these variables so that the youngest patients with superficial strokes and without vascular risk factors have the highest score. PFO prevalence increased from 23% (95% confidence interval [CI]: 19%-26%) in those with 0 to 3 points to 73% (95% CI: 66%-79%) in those with 9 or 10 points, corresponding to attributable fraction estimates of approximately 0% to 90%. Kaplan-Meier estimated stroke/TIA 2-year recurrence rates decreased from 20% (95% CI: 12%-28%) in the lowest Risk of Paradoxical Embolism score stratum to 2% (95% CI: 0%-4%) in the highest. CONCLUSION: Clinical characteristics identify CS patients who vary markedly in PFO prevalence, reflecting clinically important variation in the probability that a discovered PFO is likely to be stroke-related vs incidental. Patients in strata more likely to have stroke-related PFOs have lower recurrence risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.0b013e3182a08d59

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 637

Metadata

Authors
Kent, D. M., Ruthazer, R., Weimar, C., Mas, J.-L., Serena, J., Homma, S., Di Angelantonio, E., Di Tullio, M. R., Lutz, J. S., Elkind, M. S. V., Griffith, J., Jaigobin, C., Mattle, H. P., Michel, P., Mono, M.-L., Nedeltchev, K., Papetti, F., & Thaler, D. E.
Venue
Neurology
Published
2013-08-13
Volume
81
Issue
7
Pages
619-625
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W1974635311
Cited by
637
References
25
FWCI
20.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An index to identify stroke-related vs incidental patent foramen ovale in cryptogenic stroke. https://app.cochat.ai/papers/10.1212/wnl.0b013e3182a08d59
The paper
Kent, D. M., Ruthazer, R., Weimar, C., Mas, J.-L., Serena, J., Homma, S., Di Angelantonio, E., Di Tullio, M. R., Lutz, J. S., Elkind, M. S. V., Griffith, J., Jaigobin, C., Mattle, H. P., Michel, P., Mono, M.-L., Nedeltchev, K., Papetti, F., & Thaler, D. E. (2013). An index to identify stroke-related vs incidental patent foramen ovale in cryptogenic stroke. Neurology. https://doi.org/10.1212/wnl.0b013e3182a08d59

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.