The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Heat-Stable Carbetocin versus Oxytocin to Prevent Hemorrhage after Vaginal Birth
Open accessAbstract
BACKGROUND: Postpartum hemorrhage is the most common cause of maternal death. Oxytocin is the standard therapy for the prevention of postpartum hemorrhage, but it requires cold storage, which is not available in many countries. In a large trial, we compared a novel formulation of heat-stable carbetocin with oxytocin. METHODS: We enrolled women across 23 sites in 10 countries in a randomized, double-blind, noninferiority trial comparing intramuscular injections of heat-stable carbetocin (at a dose of 100 μg) with oxytocin (at a dose of 10 IU) administered immediately after vaginal birth. Both drugs were kept in cold storage (2 to 8°C) to maintain double-blinding. There were two primary outcomes: the proportion of women with blood loss of at least 500 ml or the use of additional uterotonic agents, and the proportion of women with blood loss of at least 1000 ml. The noninferiority margins for the relative risks of these outcomes were 1.16 and 1.23, respectively. RESULTS: A total of 29,645 women underwent randomization. The frequency of blood loss of at least 500 ml or the use of additional uterotonic agents was 14.5% in the carbetocin group and 14.4% in the oxytocin group (relative risk, 1.01; 95% confidence interval [CI], 0.95 to 1.06), a finding that was consistent with noninferiority. The frequency of blood loss of at least 1000 ml was 1.51% in the carbetocin group and 1.45% in the oxytocin group (relative risk, 1.04; 95% CI, 0.87 to 1.25), with the confidence interval crossing the margin of noninferiority. The use of additional uterotonic agents, interventions to stop bleeding, and adverse effects did not differ significantly between the two groups. CONCLUSIONS: Heat-stable carbetocin was noninferior to oxytocin for the prevention of blood loss of at least 500 ml or the use of additional uterotonic agents. Noninferiority was not shown for the outcome of blood loss of at least 1000 ml; low event rates for this outcome reduced the power of the trial. (Funded by Merck Sharpe & Dohme; CHAMPION Australian New Zealand Clinical Trials Registry number, ACTRN12614000870651 ; EudraCT number, 2014-004445-26 ; and Clinical Trials Registry-India number, CTRI/2016/05/006969 .).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global causes of maternal death: a WHO systematic analysis
Say, L., Chou, D., Gemmill, A., Tunçalp, Ö., Moller, A.-B., Daniels, J., Gülmezoglu, A. M., Temmerman, M., & Alkema, L. (2014) · The Lancet Global Health · doi:10.1016/s2214-109x(14)70227-x · Cited by 6,582
Self-citation
Cited by
FIGO recommendations on the management of postpartum hemorrhage 2022
Escobar, M. F., Nassar, A. H., Theron, G., Barnea, E. R., Nicholson, W., Ramasauskaite, D., Lloyd, I., Chandraharan, E., Miller, S., Burke, T., et al. (2022) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.14116 · Cited by 406
Metadata
- Authors
- Widmer, M., Piaggio, G., Nguyen, T. M. H., Osoti, A., Owa, O. O., Misra, S., Coomarasamy, A., Abdel-Aleem, H., Mallapur, A. A., Qureshi, Z., Lumbiganon, P., Patel, A. B., Carroli, G., Fawole, B., Goudar, S. S., Pujar, Y. V., Neilson, J., Hofmeyr, G. J., Su, L. L., Ferreira de Carvalho, J., Pandey, U., Mugerwa, K., Shiragur, S. S., Byamugisha, J., Giordano, D., & Gülmezoglu, A. M.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2018-08-23
- Volume
- 379
- Issue
- 8
- Pages
- 743-752
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2811495257
- Cited by
- 209
- References
- 1
- FWCI
- 20.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.