Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 249

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Bag-Mask Ventilation during Tracheal Intubation of Critically Ill Adults

Open access
Casey, Jonathan D., Janz, David R., Russell, Derek W., Vonderhaar, Derek J., Joffe, Aaron M., Dischert, Kevin M., Brown, Ryan M., Zouk, Aline N., Gulati, Swati, Heideman, Brent E., Lester, Michael G., Toporek, Alexandra H., Bentov, Itay, Self, Wesley H., Rice, Todd W., Semler, Matthew W. · 2019 · New England Journal of Medicine

Abstract

BACKGROUND: Hypoxemia is the most common complication during tracheal intubation of critically ill adults and may increase the risk of cardiac arrest and death. Whether positive-pressure ventilation with a bag-mask device (bag-mask ventilation) during tracheal intubation of critically ill adults prevents hypoxemia without increasing the risk of aspiration remains controversial. METHODS: In a multicenter, randomized trial conducted in seven intensive care units in the United States, we randomly assigned adults undergoing tracheal intubation to receive either ventilation with a bag-mask device or no ventilation between induction and laryngoscopy. The primary outcome was the lowest oxygen saturation observed during the interval between induction and 2 minutes after tracheal intubation. The secondary outcome was the incidence of severe hypoxemia, defined as an oxygen saturation of less than 80%. RESULTS: Among the 401 patients enrolled, the median lowest oxygen saturation was 96% (interquartile range, 87 to 99) in the bag-mask ventilation group and 93% (interquartile range, 81 to 99) in the no-ventilation group (P = 0.01). A total of 21 patients (10.9%) in the bag-mask ventilation group had severe hypoxemia, as compared with 45 patients (22.8%) in the no-ventilation group (relative risk, 0.48; 95% confidence interval [CI], 0.30 to 0.77). Operator-reported aspiration occurred during 2.5% of intubations in the bag-mask ventilation group and during 4.0% in the no-ventilation group (P = 0.41). The incidence of new opacity on chest radiography in the 48 hours after tracheal intubation was 16.4% and 14.8%, respectively (P = 0.73). CONCLUSIONS: Among critically ill adults undergoing tracheal intubation, patients receiving bag-mask ventilation had higher oxygen saturations and a lower incidence of severe hypoxemia than those receiving no ventilation. (Funded by Vanderbilt Institute for Clinical and Translational Research and others; PreVent ClinicalTrials.gov number, NCT03026322.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1812405

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 249

Metadata

Authors
Casey, J. D., Janz, D. R., Russell, D. W., Vonderhaar, D. J., Joffe, A. M., Dischert, K. M., Brown, R. M., Zouk, A. N., Gulati, S., Heideman, B. E., Lester, M. G., Toporek, A. H., Bentov, I., Self, W. H., Rice, T. W., & Semler, M. W.
Venue
New England Journal of Medicine
Published
2019-02-28
Volume
380
Issue
9
Pages
811-821
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2916303890
Cited by
249
References
1
FWCI
37.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bag-Mask Ventilation during Tracheal Intubation of Critically Ill Adults. https://app.cochat.ai/papers/10.1056/nejmoa1812405
The paper
Casey, J. D., Janz, D. R., Russell, D. W., Vonderhaar, D. J., Joffe, A. M., Dischert, K. M., Brown, R. M., Zouk, A. N., Gulati, S., Heideman, B. E., Lester, M. G., Toporek, A. H., Bentov, I., Self, W. H., Rice, T. W., & Semler, M. W. (2019). Bag-Mask Ventilation during Tracheal Intubation of Critically Ill Adults. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1812405

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.