The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Pregnancy-Adapted YEARS Algorithm for Diagnosis of Suspected Pulmonary Embolism
Open accessAbstract
BACKGROUND: Pulmonary embolism is one of the leading causes of maternal death in the Western world. Because of the low specificity and sensitivity of the d-dimer test, all pregnant women with suspected pulmonary embolism undergo computed tomographic (CT) pulmonary angiography or ventilation-perfusion scanning, both of which involve radiation exposure to the mother and fetus. Whether a pregnancy-adapted algorithm could be used to safely avoid diagnostic imaging in pregnant women with suspected pulmonary embolism is unknown. METHODS: In a prospective study involving pregnant women with suspected pulmonary embolism, we assessed three criteria from the YEARS algorithm (clinical signs of deep-vein thrombosis, hemoptysis, and pulmonary embolism as the most likely diagnosis) and measured the d-dimer level. Pulmonary embolism was ruled out if none of the three criteria were met and the d-dimer level was less than 1000 ng per milliliter or if one or more of the three criteria were met and the d-dimer level was less than 500 ng per milliliter. Adaptation of the YEARS algorithm for pregnant women involved compression ultrasonography for women with symptoms of deep-vein thrombosis; if the results were positive (i.e., a clot was present), CT pulmonary angiography was not performed. All patients in whom pulmonary embolism had not been ruled out underwent CT pulmonary angiography. The primary outcome was the incidence of venous thromboembolism at 3 months. The secondary outcome was the proportion of patients in whom CT pulmonary angiography was not indicated to safely rule out pulmonary embolism. RESULTS: A total of 510 women were screened, of whom 12 (2.4%) were excluded. Pulmonary embolism was diagnosed in 20 patients (4.0%) at baseline. During follow-up, popliteal deep-vein thrombosis was diagnosed in 1 patient (0.21%; 95% confidence interval [CI], 0.04 to 1.2); no patient had pulmonary embolism. CT pulmonary angiography was not indicated, and thus was avoided, in 195 patients (39%; 95% CI, 35 to 44). The efficiency of the algorithm was highest during the first trimester of pregnancy and lowest during the third trimester; CT pulmonary angiography was avoided in 65% of patients who began the study in the first trimester and in 32% who began the study in the third trimester. CONCLUSIONS: Pulmonary embolism was safely ruled out by the pregnancy-adapted YEARS diagnostic algorithm across all trimesters of pregnancy. CT pulmonary angiography was avoided in 32 to 65% of patients. (Funded by Leiden University Medical Center and 17 other participating hospitals; Artemis Netherlands Trial Register number, NL5726.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antithrombotic Therapy for VTE Disease
Kearon, C., Akl, E. A., Ornelas, J., Blaivas, A., Jimenez, D., Bounameaux, H., Huisman, M., King, C. S., Morris, T. A., Sood, N., et al. (2016) · Chest · doi:10.1016/j.chest.2015.11.026 · Cited by 4,830
Self-citation2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Self-citationAnderson, D., Rodger, M., Ginsberg, J., Kearon, C., Gent, M., Turpie, A., Bormanis, J., Weitz, J., Chamberlain, M., Bowie, D., et al. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613830 · Cited by 1,659
Heit, J. A., Kobbervig, C. E., James, A. H., Petterson, T. M., Bailey, K. R., & Melton, L. J. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-143-10-200511150-00006 · Cited by 1,338
James, A. H., Jamison, M. G., Brancazio, L. R., & Myers, E. R. (2006) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2005.11.008 · Cited by 979
Age-Adjusted D-Dimer Cutoff Levels to Rule Out Pulmonary Embolism: The ADJUST-PE Study
Righini, M., Van Es, J., Den Exter, P. L., Roy, P.-M., Verschuren, F., Ghuysen, A., Rutschmann, O. T., Sanchez, O., Jaffrelot, M., Trinh-Duc, A., et al. (2014) · JAMA · doi:10.1001/jama.2014.2135 · Cited by 958
Self-citationBritish Thoracic Society guidelines for the management of suspected acute pulmonary embolism
(2003) · Thorax · doi:10.1136/thorax.58.6.470 · Cited by 686
van der Hulle, T., Cheung, W. Y., Kooij, S., Beenen, L. F. M., van Bemmel, T., van Es, J., Faber, L. M., Hazelaar, G. M., Heringhaus, C., Hofstee, H., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30885-1 · Cited by 548
Self-citationManagement of venous thrombo-embolism: an update
Konstantinides, S., & Torbicki, A. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu243 · Cited by 383
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
Self-citationKonstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Self-citationMehta, L. S., Warnes, C. A., Bradley, E., Burton, T., Economy, K., Mehran, R., Safdar, B., Sharma, G., Wood, M., Valente, A. M., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000772 · Cited by 464
Metadata
- Authors
- van der Pol, L. M., Tromeur, C., Bistervels, I. M., Ni Ainle, F., van Bemmel, T., Bertoletti, L., Couturaud, F., van Dooren, Y. P. A., Elias, A., Faber, L. M., Hofstee, H. M. A., van der Hulle, T., Kruip, M. J. H. A., Maignan, M., Mairuhu, A. T. A., Middeldorp, S., Nijkeuter, M., Roy, P.-M., Sanchez, O., Schmidt, J., ten Wolde, M., Klok, F. A., & Huisman, M. V.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2019-03-21
- Volume
- 380
- Issue
- 12
- Pages
- 1139-1149
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2923518692
- Cited by
- 359
- References
- 25
- FWCI
- 30.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pregnancy-Adapted YEARS Algorithm for Diagnosis of Suspected Pulmonary Embolism. https://app.cochat.ai/papers/10.1056/nejmoa1813865
- The paper
- van der Pol, L. M., Tromeur, C., Bistervels, I. M., Ni Ainle, F., van Bemmel, T., Bertoletti, L., Couturaud, F., van Dooren, Y. P. A., Elias, A., Faber, L. M., Hofstee, H. M. A., van der Hulle, T., Kruip, M. J. H. A., Maignan, M., Mairuhu, A. T. A., Middeldorp, S., Nijkeuter, M., Roy, P.-M., Sanchez, O., . . . Huisman, M. V. (2019). Pregnancy-Adapted YEARS Algorithm for Diagnosis of Suspected Pulmonary Embolism. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1813865
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.