Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 359

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Pregnancy-Adapted YEARS Algorithm for Diagnosis of Suspected Pulmonary Embolism

Open access
van der Pol, Liselotte M., Tromeur, Cecile, Bistervels, Ingrid M., Ni Ainle, Fionnuala, van Bemmel, Thomas, Bertoletti, Laurent, Couturaud, Francis, van Dooren, Yordi P.A., Elias, Antoine, Faber, Laura M., Hofstee, Herman M.A., van der Hulle, Tom, Kruip, Marieke J.H.A., Maignan, Maxime, Mairuhu, Albert T.A., Middeldorp, Saskia, Nijkeuter, Mathilde, Roy, Pierre-Marie, Sanchez, Olivier, Schmidt, Jeannot, ten Wolde, Marije, Klok, Frederikus A., Huisman, Menno V.·2019·New England Journal of Medicine

Abstract

BACKGROUND: Pulmonary embolism is one of the leading causes of maternal death in the Western world. Because of the low specificity and sensitivity of the d-dimer test, all pregnant women with suspected pulmonary embolism undergo computed tomographic (CT) pulmonary angiography or ventilation-perfusion scanning, both of which involve radiation exposure to the mother and fetus. Whether a pregnancy-adapted algorithm could be used to safely avoid diagnostic imaging in pregnant women with suspected pulmonary embolism is unknown. METHODS: In a prospective study involving pregnant women with suspected pulmonary embolism, we assessed three criteria from the YEARS algorithm (clinical signs of deep-vein thrombosis, hemoptysis, and pulmonary embolism as the most likely diagnosis) and measured the d-dimer level. Pulmonary embolism was ruled out if none of the three criteria were met and the d-dimer level was less than 1000 ng per milliliter or if one or more of the three criteria were met and the d-dimer level was less than 500 ng per milliliter. Adaptation of the YEARS algorithm for pregnant women involved compression ultrasonography for women with symptoms of deep-vein thrombosis; if the results were positive (i.e., a clot was present), CT pulmonary angiography was not performed. All patients in whom pulmonary embolism had not been ruled out underwent CT pulmonary angiography. The primary outcome was the incidence of venous thromboembolism at 3 months. The secondary outcome was the proportion of patients in whom CT pulmonary angiography was not indicated to safely rule out pulmonary embolism. RESULTS: A total of 510 women were screened, of whom 12 (2.4%) were excluded. Pulmonary embolism was diagnosed in 20 patients (4.0%) at baseline. During follow-up, popliteal deep-vein thrombosis was diagnosed in 1 patient (0.21%; 95% confidence interval [CI], 0.04 to 1.2); no patient had pulmonary embolism. CT pulmonary angiography was not indicated, and thus was avoided, in 195 patients (39%; 95% CI, 35 to 44). The efficiency of the algorithm was highest during the first trimester of pregnancy and lowest during the third trimester; CT pulmonary angiography was avoided in 65% of patients who began the study in the first trimester and in 32% who began the study in the third trimester. CONCLUSIONS: Pulmonary embolism was safely ruled out by the pregnancy-adapted YEARS diagnostic algorithm across all trimesters of pregnancy. CT pulmonary angiography was avoided in 32 to 65% of patients. (Funded by Leiden University Medical Center and 17 other participating hospitals; Artemis Netherlands Trial Register number, NL5726.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1813865

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 359

Metadata

Authors
van der Pol, L. M., Tromeur, C., Bistervels, I. M., Ni Ainle, F., van Bemmel, T., Bertoletti, L., Couturaud, F., van Dooren, Y. P. A., Elias, A., Faber, L. M., Hofstee, H. M. A., van der Hulle, T., Kruip, M. J. H. A., Maignan, M., Mairuhu, A. T. A., Middeldorp, S., Nijkeuter, M., Roy, P.-M., Sanchez, O., Schmidt, J., ten Wolde, M., Klok, F. A., & Huisman, M. V.
Venue
New England Journal of Medicine
Published
2019-03-21
Volume
380
Issue
12
Pages
1139-1149
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2923518692
Cited by
359
References
25
FWCI
30.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pregnancy-Adapted YEARS Algorithm for Diagnosis of Suspected Pulmonary Embolism. https://app.cochat.ai/papers/10.1056/nejmoa1813865
The paper
van der Pol, L. M., Tromeur, C., Bistervels, I. M., Ni Ainle, F., van Bemmel, T., Bertoletti, L., Couturaud, F., van Dooren, Y. P. A., Elias, A., Faber, L. M., Hofstee, H. M. A., van der Hulle, T., Kruip, M. J. H. A., Maignan, M., Mairuhu, A. T. A., Middeldorp, S., Nijkeuter, M., Roy, P.-M., Sanchez, O., . . . Huisman, M. V. (2019). Pregnancy-Adapted YEARS Algorithm for Diagnosis of Suspected Pulmonary Embolism. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1813865

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.