Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 4,847

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients

Open access
Mack, Michael J., Leon, Martin B., Thourani, Vinod H., Makkar, Raj, Kodali, Susheel K., Russo, Mark, Kapadia, Samir R., Malaisrie, S. Chris, Cohen, David J., Pibarot, Philippe, Leipsic, Jonathon, Hahn, Rebecca T., Blanke, Philipp, Williams, Mathew R., McCabe, James M., Brown, David L., Babaliaros, Vasilis, Goldman, Scott, Szeto, Wilson Y., Genereux, Philippe, Pershad, Ashish, Pocock, Stuart J., Alu, Maria C., Webb, John G., Smith, Craig R.·2019·New England Journal of Medicine

Abstract

BACKGROUND: Among patients with aortic stenosis who are at intermediate or high risk for death with surgery, major outcomes are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. There is insufficient evidence regarding the comparison of the two procedures in patients who are at low risk. METHODS: We randomly assigned patients with severe aortic stenosis and low surgical risk to undergo either TAVR with transfemoral placement of a balloon-expandable valve or surgery. The primary end point was a composite of death, stroke, or rehospitalization at 1 year. Both noninferiority testing (with a prespecified margin of 6 percentage points) and superiority testing were performed in the as-treated population. RESULTS: At 71 centers, 1000 patients underwent randomization. The mean age of the patients was 73 years, and the mean Society of Thoracic Surgeons risk score was 1.9% (with scores ranging from 0 to 100% and higher scores indicating a greater risk of death within 30 days after the procedure). The Kaplan-Meier estimate of the rate of the primary composite end point at 1 year was significantly lower in the TAVR group than in the surgery group (8.5% vs. 15.1%; absolute difference, -6.6 percentage points; 95% confidence interval [CI], -10.8 to -2.5; P<0.001 for noninferiority; hazard ratio, 0.54; 95% CI, 0.37 to 0.79; P = 0.001 for superiority). At 30 days, TAVR resulted in a lower rate of stroke than surgery (P = 0.02) and in lower rates of death or stroke (P = 0.01) and new-onset atrial fibrillation (P<0.001). TAVR also resulted in a shorter index hospitalization than surgery (P<0.001) and in a lower risk of a poor treatment outcome (death or a low Kansas City Cardiomyopathy Questionnaire score) at 30 days (P<0.001). There were no significant between-group differences in major vascular complications, new permanent pacemaker insertions, or moderate or severe paravalvular regurgitation. CONCLUSIONS: Among patients with severe aortic stenosis who were at low surgical risk, the rate of the composite of death, stroke, or rehospitalization at 1 year was significantly lower with TAVR than with surgery. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1814052

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 4,847

Metadata

Authors
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., Leipsic, J., Hahn, R. T., Blanke, P., Williams, M. R., McCabe, J. M., Brown, D. L., Babaliaros, V., Goldman, S., Szeto, W. Y., Genereux, P., Pershad, A., Pocock, S. J., Alu, M. C., Webb, J. G., & Smith, C. R.
Venue
New England Journal of Medicine
Published
2019-05-02
Volume
380
Issue
18
Pages
1695-1705
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2921388585
Cited by
4,847
References
5
FWCI
445.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. https://app.cochat.ai/papers/10.1056/nejmoa1814052
The paper
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., Leipsic, J., Hahn, R. T., Blanke, P., Williams, M. R., McCabe, J. M., Brown, D. L., Babaliaros, V., Goldman, S., Szeto, W. Y., . . . Smith, C. R. (2019). Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1814052

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.