Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 3,674

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients

Open access
Popma, Jeffrey J., Deeb, G. Michael, Yakubov, Steven J., Mumtaz, Mubashir, Gada, Hemal, O’Hair, Daniel, Bajwa, Tanvir, Heiser, John C., Merhi, William, Kleiman, Neal S., Askew, Judah, Sorajja, Paul, Rovin, Joshua, Chetcuti, Stanley J., Adams, David H., Teirstein, Paul S., Zorn, George L., Forrest, John K., Tchétché, Didier, Resar, Jon, Walton, Antony, Piazza, Nicolo, Ramlawi, Basel, Robinson, Newell, Petrossian, George, Gleason, Thomas G., Oh, Jae K., Boulware, Michael J., Qiao, Hongyan, Mugglin, Andrew S., Reardon, Michael J.·2019·New England Journal of Medicine

Abstract

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. METHODS: We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. RESULTS: ). CONCLUSIONS: In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1816885

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 3,674

Metadata

Authors
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., Askew, J., Sorajja, P., Rovin, J., Chetcuti, S. J., Adams, D. H., Teirstein, P. S., Zorn, G. L., Forrest, J. K., Tchétché, D., Resar, J., Walton, A., Piazza, N., Ramlawi, B., Robinson, N., Petrossian, G., Gleason, T. G., Oh, J. K., Boulware, M. J., Qiao, H., Mugglin, A. S., & Reardon, M. J.
Venue
New England Journal of Medicine
Published
2019-05-02
Volume
380
Issue
18
Pages
1706-1715
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2922215374
Cited by
3,674
References
1
FWCI
342.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients. https://app.cochat.ai/papers/10.1056/nejmoa1816885
The paper
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., Askew, J., Sorajja, P., Rovin, J., Chetcuti, S. J., Adams, D. H., Teirstein, P. S., Zorn, G. L., Forrest, J. K., Tchétché, D., . . . Reardon, M. J. (2019). Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1816885

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.