Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,312

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report

Open access
Mehra, Mandeep R., Uriel, Nir, Naka, Yoshifumi, Cleveland, Joseph C., Yuzefpolskaya, Melana, Salerno, Christopher T., Walsh, Mary N., Milano, Carmelo A., Patel, Chetan B., Hutchins, Steven W., Ransom, John, Ewald, Gregory A., Itoh, Akinobu, Raval, Nirav Y., Silvestry, Scott C., Cogswell, Rebecca, John, Ranjit, Bhimaraj, Arvind, Bruckner, Brian A., Lowes, Brian D., Um, John Y., Jeevanandam, Valluvan, Sayer, Gabriel, Mangi, Abeel A., Molina, Ezequiel J., Sheikh, Farooq, Aaronson, Keith, Pagani, Francis D., Cotts, William G., Tatooles, Antone J., Babu, Ashok, Chomsky, Don, Katz, Jason N., Tessmann, Paul B., Dean, David, Krishnamoorthy, Arun, Chuang, Joyce, Topuria, Ia, Sood, Poornima, Goldstein, Daniel J.·2019·New England Journal of Medicine

Abstract

BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1900486

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 1,312

Metadata

Authors
Mehra, M. R., Uriel, N., Naka, Y., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C. T., Walsh, M. N., Milano, C. A., Patel, C. B., Hutchins, S. W., Ransom, J., Ewald, G. A., Itoh, A., Raval, N. Y., Silvestry, S. C., Cogswell, R., John, R., Bhimaraj, A., Bruckner, B. A., Lowes, B. D., Um, J. Y., Jeevanandam, V., Sayer, G., Mangi, A. A., Molina, E. J., Sheikh, F., Aaronson, K., Pagani, F. D., Cotts, W. G., Tatooles, A. J., Babu, A., Chomsky, D., Katz, J. N., Tessmann, P. B., Dean, D., Krishnamoorthy, A., Chuang, J., Topuria, I., Sood, P., & Goldstein, D. J.
Venue
New England Journal of Medicine
Published
2019-04-25
Volume
380
Issue
17
Pages
1618-1627
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2922229775
Cited by
1,312
References
13
FWCI
55.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report. https://app.cochat.ai/papers/10.1056/nejmoa1900486
The paper
Mehra, M. R., Uriel, N., Naka, Y., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C. T., Walsh, M. N., Milano, C. A., Patel, C. B., Hutchins, S. W., Ransom, J., Ewald, G. A., Itoh, A., Raval, N. Y., Silvestry, S. C., Cogswell, R., John, R., Bhimaraj, A., Bruckner, B. A., . . . Goldstein, D. J. (2019). A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1900486

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.