The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report
Open accessAbstract
BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advanced heart failure treated with continuous-flow left ventricular assist device
Slaughter, M. S., Rogers, J. G., Milano, C. A., Russell, S. D., Conte, J. V., Feldman, D., Sun, B., Tatooles, A. J., Delgado, R. M., Long, J. W., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0909938 · Cited by 3,063
Self-citationKonstam, M. A., Kiernan, M. S., Bernstein, D., Bozkurt, B., Jacob, M., Kapur, N. K., Kociol, R. D., Lewis, E. F., Mehra, M. R., Pagani, F. D., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000560 · Cited by 945
Self-citationIntrapericardial Left Ventricular Assist Device for Advanced Heart Failure
Rogers, J. G., Pagani, F. D., Tatooles, A. J., Bhat, G., Slaughter, M. S., Birks, E. J., Boyce, S. W., Najjar, S. S., Jeevanandam, V., Anderson, A. S., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1602954 · Cited by 758
Self-citationA Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure
Mehra, M. R., Naka, Y., Uriel, N., Goldstein, D. J., Cleveland, J. C., Colombo, P. C., Walsh, M. N., Milano, C. A., Patel, C. B., Jorde, U. P., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1610426 · Cited by 751
Self-citationTwo-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure
Mehra, M. R., Goldstein, D. J., Uriel, N., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C., Walsh, M. N., Milano, C. A., Patel, C. B., Ewald, G. A., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1800866 · Cited by 722
Self-citationAnkersmit, H. J., Tugudea, S., Spanier, T., Weinberg, A. D., Artrip, J. H., Burke, E. M., Flannery, M., Mancini, D., Rose, E. A., Edwards, N. M., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10359-8 · Cited by 194
Netuka, I., Ivák, P., Tučanová, Z., Gregor, S., Szárszoi, O., Sood, P., Crandall, D., Rimsans, J., Connors, J. M., & Mehra, M. R. (2018) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2018.03.002 · Cited by 168
Self-citationTabit, C. E., Chen, P., Kim, G. H., et al. (2016) · Circulation · doi:10.1161/circulationaha.115.019692 · Cited by 154
Heatley, G. J., Sood, P., Goldstein, D. J., Uriel, N. Y., Cleveland, J. C., Middlebrook, D., & Mehra, M. R. (2016) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2016.01.021 · Cited by 151
Self-citationRich, J. D., Gošev, I., Patel, C. B., Joseph, S. M., Katz, J. N., Eckman, P., Lee, S., Sundareswaran, K. S., Kılıç, A., Bethea, B. T., et al. (2016) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2016.08.010 · Cited by 136
Self-citation
Cited by
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
Self-citation2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Self-citationAdvanced Heart Failure Therapies for Hypertrophic Cardiomyopathy
Liang, L. W., Lumish, H. S., Sewanan, L. R., Shimada, Y. J., Maurer, M. S., Weiner, S. D., Sayer, G., Uriel, N., & Clerkin, K. J. (2023) · JACC: Heart Failure · doi:10.1016/j.jchf.2023.07.004 · Cited by 30
Self-citation
Metadata
- Authors
- Mehra, M. R., Uriel, N., Naka, Y., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C. T., Walsh, M. N., Milano, C. A., Patel, C. B., Hutchins, S. W., Ransom, J., Ewald, G. A., Itoh, A., Raval, N. Y., Silvestry, S. C., Cogswell, R., John, R., Bhimaraj, A., Bruckner, B. A., Lowes, B. D., Um, J. Y., Jeevanandam, V., Sayer, G., Mangi, A. A., Molina, E. J., Sheikh, F., Aaronson, K., Pagani, F. D., Cotts, W. G., Tatooles, A. J., Babu, A., Chomsky, D., Katz, J. N., Tessmann, P. B., Dean, D., Krishnamoorthy, A., Chuang, J., Topuria, I., Sood, P., & Goldstein, D. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2019-04-25
- Volume
- 380
- Issue
- 17
- Pages
- 1618-1627
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2922229775
- Cited by
- 1,312
- References
- 13
- FWCI
- 55.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report. https://app.cochat.ai/papers/10.1056/nejmoa1900486
- The paper
- Mehra, M. R., Uriel, N., Naka, Y., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C. T., Walsh, M. N., Milano, C. A., Patel, C. B., Hutchins, S. W., Ransom, J., Ewald, G. A., Itoh, A., Raval, N. Y., Silvestry, S. C., Cogswell, R., John, R., Bhimaraj, A., Bruckner, B. A., . . . Goldstein, D. J. (2019). A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1900486
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.