CoChat

Drug-Coated Balloons for Dysfunctional Dialysis Arteriovenous Fistulas

Open access
Lookstein, Robert A., Haruguchi, Hiroaki, Ouriel, Kenneth, Weinberg, Ido, Lei, Lanyu, Cihlar, Stephanie, Holden, Andrew · 2020 · New England Journal of Medicine
Cited by 219

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Standard percutaneous transluminal angioplasty is the current recommended treatment for dysfunctional hemodialysis fistulas, yet long-term outcomes of this treatment are poor. Drug-coated balloons delivering the antirestenotic agent paclitaxel may improve outcomes. METHODS: In this prospective, single-blinded, 1:1 randomized trial, we enrolled 330 participants at 29 international sites. Patients with new or restenotic lesions in native upper-extremity arteriovenous fistulas were eligible for participation. After successful high-pressure percutaneous transluminal angioplasty, participants were randomly assigned to receive treatment with a drug-coated balloon or a standard balloon. The primary effectiveness end point was target-lesion primary patency, defined as freedom from clinically driven target-lesion revascularization or access-circuit thrombosis during the 6 months after the index procedure. The primary safety end point, serious adverse events involving the arteriovenous access circuit within 30 days, was assessed in a noninferiority analysis (margin of noninferiority, 7.5 percentage points). The primary analyses included all participants with available end-point data. Additional sensitivity analyses were performed to assess the effect of missing data. RESULTS: A total of 330 participants underwent randomization; 170 were assigned to receive treatment with a drug-coated balloon, and 160 were assigned to receive treatment with a standard balloon. During the 6 months after the index procedure, target-lesion primary patency was maintained more often in participants who had been treated with a drug-coated balloon than in those who had been treated with a standard balloon (82.2% [125 of 152] vs. 59.5% [88 of 148]; difference in risk, 22.8 percentage points; 95% confidence interval [CI], 12.8 to 32.8; P<0.001). Drug-coated balloons were noninferior to standard balloons with respect to the primary safety end point (4.2% [7 of 166] and 4.4% [7 of 158], respectively; difference in risk, -0.2 percentage points; 95% CI, -5.5 to 5.0; P = 0.002 for noninferiority). Sensitivity analyses confirmed the results of the primary analyses. CONCLUSIONS: Drug-coated balloon angioplasty was superior to standard angioplasty for the treatment of stenotic lesions in dysfunctional hemodialysis arteriovenous fistulas during the 6 months after the procedure and was noninferior with respect to access circuit-related serious adverse events within 30 days. (Funded by Medtronic; IN.PACT AV Access Study ClinicalTrials.gov number, NCT03041467.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa1914617

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 219

Metadata

Authors
Lookstein, R. A., Haruguchi, H., Ouriel, K., Weinberg, I., Lei, L., Cihlar, S., & Holden, A.
Venue
New England Journal of Medicine
Published
2020-08-20
Volume
383
Issue
8
Pages
733-742
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W3062066963
Cited by
219
References
14
FWCI
26.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.