The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Intermittently Scanned Continuous Glucose Monitoring for Type 1 Diabetes
Open accessAbstract
BACKGROUND: In persons with type 1 diabetes and high glycated hemoglobin levels, the benefits of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels are uncertain. METHODS: In a parallel-group, multicenter, randomized, controlled trial involving participants with type 1 diabetes and glycated hemoglobin levels between 7.5% and 11.0%, we investigated the efficacy of intermittently scanned continuous glucose monitoring as compared with participant monitoring of blood glucose levels with fingerstick testing. The primary outcome was the glycated hemoglobin level at 24 weeks, analyzed according to the intention-to-treat principle. Key secondary outcomes included sensor data, participant-reported outcome measures, and safety. RESULTS: A total of 156 participants were randomly assigned, in a 1:1 ratio, to undergo intermittently scanned continuous glucose monitoring (the intervention group, 78 participants) or to monitor their own blood glucose levels with fingerstick testing (the usual-care group, 78 participants). At baseline, the mean (±SD) age of the participants was 44±15 years, and the mean duration of diabetes was 21±13 years; 44% of the participants were women. The mean baseline glycated hemoglobin level was 8.7±0.9% in the intervention group and 8.5±0.8% in the usual-care group; these levels decreased to 7.9±0.8% and 8.3±0.9%, respectively, at 24 weeks (adjusted mean between-group difference, -0.5 percentage points; 95% confidence interval [CI], -0.7 to -0.3; P<0.001). The time per day that the glucose level was in the target range was 9.0 percentage points (95% CI, 4.7 to 13.3) higher or 130 minutes (95% CI, 68 to 192) longer in the intervention group than in the usual-care group, and the time spent in a hypoglycemic state (blood glucose level, <70 mg per deciliter [<3.9 mmol per liter]) was 3.0 percentage points (95% CI, 1.4 to 4.5) lower or 43 minutes (95% CI, 20 to 65) shorter in the intervention group. Two participants in the usual-care group had an episode of severe hypoglycemia, and 1 participant in the intervention group had a skin reaction to the sensor. CONCLUSIONS: Among participants with type 1 diabetes and high glycated hemoglobin levels, the use of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels resulted in significantly lower glycated hemoglobin levels than levels monitored by fingerstick testing. (Funded by Diabetes UK and others; FLASH-UK ClinicalTrials.gov number, NCT03815006.).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Multiple imputation using chained equations: Issues and guidance for practice
White, I. R., Royston, P., & Wood, A. M. (2011) · Statistics in Medicine · doi:10.1002/sim.4067 · Cited by 9,792
State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Assessing Psychosocial Distress in Diabetes
Polonsky, W. H., Fisher, L., Earles, J., Dudl, R. J., Lees, J., Mullan, J., & Jackson, R. A. (2005) · Diabetes Care · doi:10.2337/diacare.28.3.626 · Cited by 1,575
Gilbody, S., Richards, D., Brealey, S., & Hewitt, C. (2007) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0333-y · Cited by 1,290
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Daneman, D. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68341-4 · Cited by 921
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Reddy, M., Jugnee, N., El Laboudi, A., Spanudakis, E., Anantharaja, S., & Oliver, N. (2018) · Diabetic Medicine · doi:10.1111/dme.13561 · Cited by 245
Cro, S., Morris, T. P., Kenward, M. G., & Carpenter, J. R. (2020) · Statistics in Medicine · doi:10.1002/sim.8569 · Cited by 203
Cited by
Continuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Wearable Devices in Cardiovascular Medicine
Hughes, A., Shandhi, M. M. H., Master, H., Dunn, J., & Brittain, E. (2023) · Circulation Research · doi:10.1161/circresaha.122.322389 · Cited by 291
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Metadata
- Authors
- Leelarathna, L., Evans, M. L., Neupane, S., Rayman, G., Lumley, S., Cranston, I., Narendran, P., Barnard-Kelly, K., Sutton, C. J., Elliott, R. A., Taxiarchi, V. P., Gkountouras, G., Burns, M., Mubita, W., Kanumilli, N., Camm, M., Thabit, H., & Wilmot, E. G.
- Affiliations
- University of Cambridge (GB)
- University Hospitals Birmingham NHS Foundation Trust (GB)
- From the Diabetes, Endocrinology, and Metabolism Centre, Manchester Royal Infirmary, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre (L.L., W.M., N.K., M.C., H.T.), the Division of Diabetes, Endocrinology, and Gastroenterology, Faculty of Biology, Medicine, and Health (L.L., H.T.), and the Centre for Biostatistics (C.J.S., V.P.T.), the Manchester Centre for Health Economics (R.A.E., G.G.), and the Manchester Clinical Trials Unit (C.J.S., M.B.), Division of Population Health, Health Service Research and Primary Care, University of Manchester, Manchester, Wellcome Trust–Medical Research Council Institute of Metabolic Science, National Institute for Health and Care Research Cambridge Biomedical Research Centre, Cambridge University Hospitals and University of Cambridge, Cambridge (M.L.E.), Elsie Bertram Diabetes Centre, Norfolk (S.N.), Norwich University Hospitals NHS Foundation Trust, Norwich (S.N.), the Diabetes and Endocrine Centre, Ipswich Hospital, East Suffolk and N...
- University of Nottingham (GB)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2022-10-20
- Volume
- 387
- Issue
- 16
- Pages
- 1477-1487
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4302023802
- Cited by
- 174
- References
- 26
- Citations by year
- 2026: 23 · 2025: 45 · 2024: 49 · 2023: 49 · 2022: 7
- FWCI
- 27.77
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Licence
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- Research Explorer (The University of Manchester) (submittedVersion, other-oa)
- Funders
- Diabetes UK (18/0005836)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- intermittently scanned continuous glucose monitoring, type 1 diabetes, HbA1c, glycemic control, hypoglycemia, time in range, patient-reported outcomes, diabetes self-management, glycemic variability, HbA1c reduction, hypoglycemia risk reduction, severe hypoglycemia
- MeSH terms
- Adult, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Male, Middle Aged, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intermittently Scanned Continuous Glucose Monitoring for Type 1 Diabetes. https://app.cochat.ai/papers/10.1056/nejmoa2205650
- The paper
- Leelarathna, L., Evans, M. L., Neupane, S., Rayman, G., Lumley, S., Cranston, I., Narendran, P., Barnard-Kelly, K., Sutton, C. J., Elliott, R. A., Taxiarchi, V. P., Gkountouras, G., Burns, M., Mubita, W., Kanumilli, N., Camm, M., Thabit, H., & Wilmot, E. G. (2022). Intermittently Scanned Continuous Glucose Monitoring for Type 1 Diabetes. New England Journal of Medicine. https://doi.org/10.1056/nejmoa2205650
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.