The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Optical Coherence Tomography–Guided versus Angiography-Guided PCI
Abstract
Data regarding clinical outcomes after optical coherence tomography (OCT)–guided percutaneous coronary intervention (PCI) as compared with angiography-guided PCI are limited. Download a PDF of the Research Summary. In this prospective, randomized, single-blind trial, we randomly assigned patients with medication-treated diabetes or complex coronary-artery lesions to undergo OCT-guided PCI or angiography-guided PCI. A final blinded OCT procedure was performed in patients in the angiography group. The two primary efficacy end points were the minimum stent area after PCI as assessed with OCT and target-vessel failure at 2 years, defined as a composite of death from cardiac causes, target-vessel myocardial infarction, or ischemia-driven target-vessel revascularization. Safety was also assessed. The trial was conducted at 80 sites in 18 countries. A total of 2487 patients underwent randomization: 1233 patients were assigned to undergo OCT-guided PCI, and 1254 to undergo angiography-guided PCI. The minimum stent area after PCI was 5.72±2.04 mm2 in the OCT group and 5.36±1.87 mm2 in the angiography group (mean difference, 0.36 mm2; 95% confidence interval [CI], 0.21 to 0.51; P<0.001). Target-vessel failure within 2 years occurred in 88 patients in the OCT group and in 99 patients in the angiography group (Kaplan–Meier estimates, 7.4% and 8.2%, respectively; hazard ratio, 0.90; 95% CI, 0.67 to 1.19; P=0.45). OCT-related adverse events occurred in 1 patient in the OCT group and in 2 patients in the angiography group. Stent thrombosis within 2 years occurred in 6 patients (0.5%) in the OCT group and in 17 patients (1.4%) in the angiography group. Among patients undergoing PCI, OCT guidance resulted in a larger minimum stent area than angiography guidance, but there was no apparent between-group difference in the percentage of patients with target-vessel failure at 2 years. (Funded by Abbott; ILUMIEN IV: OPTIMAL PCI ClinicalTrials.gov number, NCT03507777.) QUICK TAKE VIDEO SUMMARYOCT-Guided vs. Angiography-Guided PCI 02:10
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduced Rate of Hospital Admissions for ACS during Covid-19 Outbreak in Northern Italy
De Filippo, O., D’Ascenzo, F., Angelini, F., Bocchino, P. P., Conrotto, F., Saglietto, A., Secco, G. G., Campo, G., Gallone, G., Verardi, R., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2009166 · Cited by 1,020
Reduction of hospitalizations for myocardial infarction in Italy in the COVID-19 era
De Rosa, S., Spaccarotella, C., Basso, C., Calabrò, M. P., Curcio, A., Filardi, P. P., Mancone, M., Mercuro, G., Muscoli, S., Nodari, S., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa409 · Cited by 938
COVID-19 pandemic and admission rates for and management of acute coronary syndromes in england
Mafham, M. M., Spata, E., Goldacre, R., Gair, D., Curnow, P., Bray, M., Hollings, S., Roebuck, C., Gale, C. P., Mamas, M. A., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31356-8 · Cited by 714
Ali, Z. A., Maehara, A., Généreux, P., Shlofmitz, R. A., Fabbiocchi, F., Nazif, T. M., Guagliumi, G., Meraj, P. M., Alfonso, F., Samady, H., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31922-5 · Cited by 658
Self-citationClinical Impact of OCT Findings During PCI
Prati, F., Romagnoli, E., Burzotta, F., Limbruno, U., Gatto, L., La Manna, A., Versaci, F., Marco, V., Di Vito, L., Imola, F., et al. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.08.013 · Cited by 360
Self-citationAdriaenssens, T., Joner, M., Godschalk, T. C., Malik, N., Alfonso, F., Xhepa, E., De Cock, D., Komukai, K., Tada, T., Cuesta, J., et al. (2017) · Circulation · doi:10.1161/circulationaha.117.026788 · Cited by 280
Self-citationSoeda, T., Uemura, S., Park, S.-J., Jang, Y., Lee, S., Cho, J.-M., Kim, S.-J., Vergallo, R., Minami, Y., Ong, D. S., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.014704 · Cited by 260
Clinical Utility of Intravascular Imaging
Mintz, G. S., Matsumura, M., Ali, Z. A., & Maehara, A. (2022) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2022.04.026 · Cited by 111
Self-citationImpact of post‐procedural minimal stent area on 2‐year clinical outcomes in the SYNTAX II trial
Katagiri, Y., Maria, G. L. D., Kogame, N., Chichareon, P., Takahashi, K., Chang, C. C., Modolo, R., Walsh, S. J., Sabaté, M., Davies, J. E., et al. (2019) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28105 · Cited by 43
Self-citationMalik, A. H., Yandrapalli, S., Aronow, W. S., Panza, J. A., & Cooper, H. A. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.07.033 · Cited by 38
Impact of Intravascular Ultrasound–Guided Optimal Stent Expansion on 3-Year Hard Clinical Outcomes
Lee, Y., Zhang, J., Mintz, G. S., Hong, S., Ahn, C., Kim, J., Kim, B., Ko, Y., Choi, D., Jang, Y., et al. (2021) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.121.011124 · Cited by 35
Long‐Term Outcomes and Clinical Predictors of Mortality Following Occurrence of Stent Thrombosis
Ishihara, T., Okada, K., Kida, H., Tsujimura, T., Iida, O., Okuno, S., Hata, Y., Toyoshima, T., Higashino, N., Kikuchi, A., et al. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.121.023276 · Cited by 33
Siddiqi, T. J., Khan, M. S., Galougahi, K. K., Shlofmitz, E. S., Moses, J. W., Rao, S. V., West, N. E. J., Wolff, E., Hochler, J., Chau, K., et al. (2022) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.30416 · Cited by 18
Self-citation
Cited by
2024 ESC Guidelines for the management of chronic coronary syndromes
Vrints, C., Andreotti, F., Koskinas, K. C., Rossello, X., Adamo, M., Ainslie, J., Banning, A. P., Budaj, A., Buechel, R. R., Chiariello, G. A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae177 · Cited by 2,774
Self-citationRao, S. V., O’Donoghue, M. L., Ruel, M., Rab, T., Tamis-Holland, J. E., Alexander, J. H., Baber, U., Baker, H., Cohen, M. G., Cruz-Ruiz, M., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001309 · Cited by 625
2025 ACC/AHA/ACEP/NAEMSP/SCAI Guideline for the Management of Patients With Acute Coronary Syndromes
Rao, S. V., O’Donoghue, M. L., Ruel, M., Rab, T., Tamis-Holland, J. E., Alexander, J. H., Baber, U., Baker, H., Cohen, M. G., Cruz-Ruiz, M., et al. (2025) · JACC · doi:10.1016/j.jacc.2024.11.009 · Cited by 552
Stone, G. W., Christiansen, E. H., Ali, Z. A., Andreasen, L. N., Maehara, A., Ahmad, Y., Landmesser, U., & Holm, N. R. (2024) · The Lancet · doi:10.1016/s0140-6736(23)02454-6 · Cited by 323
Self-citation
Metadata
- Authors
- Ali, Z. A., Landmesser, U., Maehara, A., Matsumura, M., Shlofmitz, R. A., Guagliumi, G., Price, M. J., Hill, J. M., Akasaka, T., Prati, F., Bezerra, H. G., Wijns, W., Leistner, D., Canova, P., Alfonso, F., Fabbiocchi, F., Dogan, O., McGreevy, R. J., McNutt, R. W., Nie, H., Buccola, J., West, N. E. J., & Stone, G. W.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2023-10-19
- Volume
- 389
- Issue
- 16
- Pages
- 1466-1476
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4386209818
- Cited by
- 309
- References
- 13
- FWCI
- 73.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.