CoChat

Efficacy and Safety of Baxdrostat in Uncontrolled and Resistant Hypertension

Open access
Flack, John M., Azizi, Michel, Brown, Jenifer M., Dwyer, Jamie P., Fronczek, Jakub, Jones, Erika S.W., Olsson, Daniel S., Perl, Shira, Shibata, Hirotaka, Wang, Ji-Guang, Wilderäng, Ulrica, Wittes, Janet, Williams, Bryan · 2025 · New England Journal of Medicine
Cited by 171

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Aldosterone dysregulation plays an important pathogenic role in hard-to-control hypertension. In several studies, baxdrostat, an aldosterone synthase inhibitor, reduced the seated systolic blood pressure of patients with uncontrolled or resistant hypertension. METHODS: In this phase 3, multinational, double-blind, randomized, placebo-controlled trial, we recruited patients with a seated systolic blood pressure of between 140 mm Hg and less than 170 mm Hg despite the receipt of stable treatment with two antihypertensive medications (uncontrolled hypertension) or three or more such medications (resistant hypertension), including a diuretic. After a 2-week placebo run-in period, we randomly assigned patients with a seated systolic blood pressure of 135 mm Hg or more in a 1:1:1 ratio to receive baxdrostat at a dose of 1 mg, baxdrostat at a dose of 2 mg, or placebo once daily for 12 weeks. The primary end point was the change in seated systolic blood pressure from baseline to week 12. RESULTS: A total of 796 patients underwent randomization and 794 received 1-mg baxdrostat (264 patients), 2-mg baxdrostat (266 patients), or placebo (264 patients) in addition to background therapy. At 12 weeks, the change from baseline in the least-squares mean seated systolic blood pressure was -14.5 mm Hg (95% confidence interval [CI], -16.5 to -12.5) with 1-mg baxdrostat, -15.7 mm Hg (95% CI, -17.6 to -13.7) with 2-mg baxdrostat, and -5.8 mm Hg (95% CI, -7.9 to -3.8) with placebo. The estimated difference from placebo (placebo-corrected difference) was -8.7 mm Hg (95% CI, -11.5 to -5.8) with 1-mg baxdrostat and -9.8 mm Hg (95% CI, -12.6 to -7.0) with 2-mg baxdrostat (P<0.001 for both comparisons). A potassium level of more than 6.0 mmol per liter was reported in 6 patients (2.3%) with 1-mg baxdrostat, in 8 patients (3.0%) with 2-mg baxdrostat, and in 1 patient (0.4%) with placebo. CONCLUSIONS: Among patients with uncontrolled or resistant hypertension, the addition of baxdrostat to background therapy resulted in a significantly lower seated systolic blood pressure at 12 weeks than placebo. (Funded by AstraZeneca and others; BaxHTN ClinicalTrials.gov number, NCT06034743.).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejmoa2507109

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Flack, J. M., Azizi, M., Brown, J. M., Dwyer, J. P., Fronczek, J., Jones, E. S. W., Olsson, D. S., Perl, S., Shibata, H., Wang, J.-G., Wilderäng, U., Wittes, J., & Williams, B.
Venue
New England Journal of Medicine
Published
2025-10-09
Volume
393
Issue
14
Pages
1363-1374
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W4413846475
Cited by
171
References
23
FWCI
101.83
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.