Pilot-Scale Electrocoagulation with Bipolar Aluminum Electrodes for On-Site Domestic Greywater Reuse
The DOI matches its Crossref record.
Abstract
Designing a reclaimed water system provides an economically and environmentally favorable method for disposing of wastewater. However, some critical influences on on-site reclaimed water systems, such as limited building area, often limit the effectiveness of conventional treatment methods. This work established a compact and inexpensive electrocoagulation process with a capacity of 28m3∕day to reclaim domestic greywater for human noncontact usage. The total unit cost of on-site domestic greywater reuse was U.S.$0.27∕m3, which was below the local potable water rate. Moreover, the treatment facility required an area of 8m2. Both unit cost and required area in this work are lower than those reported in the literature. The experimental results support the feasibility of the on-site reuse of greywater in high-rise buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A comprehensive review of electrocoagulation for water treatment: Potentials and challenges
Moussa, D. T., El-Naas, M. H., Nasser, M., & Al-Marri, M. J. (2017) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.10.032 · Cited by 963
Review of the technological approaches for grey water treatment and reuses
Li, F., Wichmann, K., & Otterpohl, R. (2009) · Science of The Total Environment · doi:10.1016/j.scitotenv.2009.02.004 · Cited by 651
Characteristics and treatment of greywater—a review
Ghaitidak, D. M., & Yadav, K. D. (2013) · Environmental Science and Pollution Research · doi:10.1007/s11356-013-1533-0 · Cited by 352
Zaied, B. K., Rashid, M., Nasrullah, M., Zularisam, A. W., Pant, D., & Singh, L. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138095 · Cited by 328
Recent progress on electrocoagulation process for wastewater treatment: A review
Das, P. P., Sharma, M., & Purkait, M. K. (2022) · Separation and Purification Technology · doi:10.1016/j.seppur.2022.121058 · Cited by 312
Metadata
- Authors
- Lin, C.-J., Lo, S.-L., Kuo, C.-Y., & Wu, C.-H.
- Venue
- Journal of Environmental Engineering
- Published
- 2005-03
- Volume
- 131
- Issue
- 3
- Pages
- 491-495
- ISSN
- 0733-9372 (ISSN-L)
- 1943-7870
- DOI
- 10.1061/(asce)0733-9372(2005)131:3(491
- OpenAlex
- W2140522184
- Cited by
- 125
- References
- 0
- FWCI
- 8.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pilot-Scale Electrocoagulation with Bipolar Aluminum Electrodes for On-Site Domestic Greywater Reuse. https://app.cochat.ai/papers/10.1061/(asce)0733-9372(2005)131:3(491
- The paper
- Lin, C.-J., Lo, S.-L., Kuo, C.-Y., & Wu, C.-H. (2005). Pilot-Scale Electrocoagulation with Bipolar Aluminum Electrodes for On-Site Domestic Greywater Reuse. Journal of Environmental Engineering. https://doi.org/10.1061/(asce)0733-9372(2005)131%3A3(491
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.