The DOI matches its Crossref record.
Frequency Domain Optimal Control Strategies for Aseismic Protection
Abstract
This paper discusses frequency domain optimal control strategies for active control of civil engineering structures under seismic loading. The basic problem formulation is presented, and a description of two specific techniques, the H2 and H∞ control methods, are given. Numerical examples showing H2 control of a seismically excited eight‐story building are given to illustrate the application and delineate the advantages of the frequency domain approaches. The main thrusts of the examples are to show that frequency‐domain design methods can be effectively used to: (1) Optimally control a structure using output feedback of acceleration measurements; and (2) selectively shape the output structural response in a desirable manner. In contrast to previously reported time‐domain‐based controllers, the numerical studies show that these control techniques are capable of reducing the building's response in both the first and second mode response using an active mass damper. The frequency domain optimal control design methods are shown to be flexible and to offer a good match between control concepts and engineering practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Passive, Adaptive and Active Tuned Vibration Absorbers—A Survey
Sun, J. Q., Jolly, M. R., & Norris, M. A. (1995) · Journal of Mechanical Design · doi:10.1115/1.2836462 · Cited by 320
LQR control with frequency‐dependent scheduled gain for a semi‐active floor isolation system
Shi, Y., Becker, T. C., Furukawa, S., Sato, E., & Nakashima, M. (2014) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2352 · Cited by 30
Structural Control Strategies for Earthquake Response Reduction of Buildings
(2014) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign) · Cited by 5
Structural Control: Past, Present, and Future
(1997) · doi:10.1061/(asce)0733-9399(1997)123:9(897
(2004) · doi:10.1061/(asce)0733-9399(2004)130:4(366
Metadata
- Authors
- Spencer, B. F., Suhardjo, J., & Sain, M. K.
- Venue
- Journal of Engineering Mechanics
- Published
- 1994-01
- Volume
- 120
- Issue
- 1
- Pages
- 135-158
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- DOI
- 10.1061/(asce)0733-9399(1994)120:1(135
- OpenAlex
- W1984521178
- Cited by
- 191
- References
- 0
- FWCI
- 50.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency Domain Optimal Control Strategies for Aseismic Protection. https://app.cochat.ai/papers/10.1061/(asce)0733-9399(1994)120:1(135
- The paper
- Spencer, B. F., Suhardjo, J., & Sain, M. K. (1994). Frequency Domain Optimal Control Strategies for Aseismic Protection. Journal of Engineering Mechanics. https://doi.org/10.1061/(asce)0733-9399(1994)120%3A1(135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.