Vibration Control of Tall Buildings Using Mega SubConfiguration
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An innovative vibration-control system is proposed to reduce the dynamic response of tall buildings to wind and seismic loads. This system takes advantage of the so-called megasubstructure configuration, which is especially popular in tall buildings. Substructures contained in the megastructure serve as energy absorbers so that no additional mass is required for the intended vibration control as seen in the conventional mass damper systems. The proposed system naturally resolves the difficulties in augmenting damping capacities of tall buildings associated with the high rigidity and deformation in the dominant bending mode. Dynamic characteristics of the proposed control system including the frequency response and the energy flow are investigated. Optimal values of structural parameters such as the damping ratio and stiffness of the substructure are determined. The feasibility and effectiveness of this unique control system in improving human comfort and protecting structures under both wind and earthquake loads are demonstrated through analytical and numerical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimum absorber parameters for various combinations of response and excitation parameters
Warburton, G. B. (1982) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290100304 · Cited by 1,043
Random Vibration in Mechanical Systems
(1963) · Elsevier eBooks · doi:10.1016/c2013-0-12506-8 · Cited by 899
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Optimal tuned mass damper for seismic applications and practical design formulas
Hoang, N., Fujino, Y., & Warnitchai, P. (2008) · Engineering Structures · doi:10.1016/j.engstruct.2007.05.007 · Cited by 382
Dynamic response and optimal design of structures with large mass ratio TMD
De Angelis, M., Perno, S., & Reggio, A. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1117 · Cited by 239
Innovations in earthquake risk reduction for resilience: Recent advances and challenges
Freddi, F., Galasso, C., Cremen, G., Dall’Asta, A., Di Sarno, L., Giaralis, A., Gutiérrez-Urzúa, F., Málaga-Chuquitaype, C., Mitoulis, S. A., Petrone, C., et al. (2021) · International Journal of Disaster Risk Reduction · doi:10.1016/j.ijdrr.2021.102267 · Cited by 224
“while suppressing more than one vibration mode [213,214].”
BackgroundReggio, A., & Angelis, M. D. (2015) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2548 · Cited by 191
“Sensitivity analyses The assumption of a stochastic white noise design input is long-established in the literature on TMD [15, 26, 27] and recognized as a reasonable idealization for its seismic design [14, 28, 29].”
BackgroundMethodStructural control and vibration issues in wind turbines: A review
Xie, F., & Aly, A.-M. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2019.110087 · Cited by 159
Seismic vibration control of building structures with multiple tuned mass damper floors integrated
Xiang, P., & Nishitani, A. (2014) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2379 · Cited by 91
Aly, A. M. (2014) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1068 · Cited by 74
Moutinho, C. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2174 · Cited by 64
Sadek (1997) · doi:10.1002/(sici)1096-9845(199706)26:6<617::aid-eqe664>3.0.co;2-z
Metadata
- Authors
- Feng, M. Q., & Mita, A.
- Venue
- Journal of Engineering Mechanics
- Published
- 1995-10
- Volume
- 121
- Issue
- 10
- Pages
- 1082-1088
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- DOI
- 10.1061/(asce)0733-9399(1995)121:10(1082
- OpenAlex
- W2001942696
- Cited by
- 176
- References
- 2
- FWCI
- 9.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.