The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
“Smart” Base Isolation Systems
Abstract
A “smart” base isolation strategy is proposed and shown to effectively protect structures against extreme earthquakes without sacrificing performance during the more frequent, moderate seismic events. The proposed smart base isolation system is composed of conventional low-damping elastomeric bearings and “smart” controllable (semiactive) dampers, such as magnetorheological fluid dampers. To demonstrate the advantages of this approach, the smart isolation system is compared to lead-rubber bearing isolation systems. The effectiveness of the isolation approaches are judged based on computed responses to several historical earthquakes scaled to various magnitudes. The limited performance of passive systems is revealed and the potential advantages of smart dampers are demonstrated. Two- and six-degree-of-freedom models of a base-isolated building are used as a test bed in this study. Smart isolation is shown to achieve notable decreases in base drifts over comparable passive systems with no accompanying increase in base shears or in accelerations imparted to the superstructure. In contrast to passive lead-rubber bearing systems, the adaptable nature of the smart damper isolation system provides good protection to both the structure and its contents over a wide range of ground motions and magnitudes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Method for Random Vibration of Hysteretic Systems
Wen, Y.-K. (1976) · Journal of the Engineering Mechanics Division · doi:10.1061/jmcea3.0002106 · Cited by 2,668
Modeling and control of magnetorheological dampers for seismic response reduction
Dyke, S. J., Spencer, B. F., Sain, M. K., & Carlson, J. D. (1996) · Smart Materials and Structures · doi:10.1088/0964-1726/5/5/006 · Cited by 1,341
Self-citationDesign of Seismic Isolated Structures: From Theory to Practice
Naeim, F., & Kelly, J. M. (1999) · Wiley eBooks · doi:10.1002/9780470172742 · Cited by 1,190
Design of seismic isolated structures : from theory to practice
Naeim, F., & Kelly, J. M. (1999) · Medical Entomology and Zoology · Cited by 937
Passive Energy Dissipation Systems in Structural Engineering
Dargush, G. F., & Soong, T. T. (1997) · Medical Entomology and Zoology · Cited by 880
4. Near‐Source Ground Motion and its Effects on Flexible Buildings
Hall, J. F., Heaton, T. H., Halling, M. W., & Wald, D. J. (1995) · Earthquake Spectra · doi:10.1193/1.1585828 · Cited by 768
Semi-active control systems for seismic protection of structures: a state-of-the-art review
Symans, M. D., & Constantinou, M. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00225-3 · Cited by 706
Earthquake-Resistant Design with Rubber
Kelly, J. M. (1997) · Springer eBooks · doi:10.1007/978-1-4471-0971-6 · Cited by 689
The role of damping in seismic isolation
Kelly, J. M. (1999) · Earthquake Engineering & Structural Dynamics · doi:10.1002/(sici)1096-9845(199901)28:1<3::aid-eqe801>3.0.co;2-d · Cited by 446
Controlling buildings: a new frontier in feedback
(1997) · IEEE Control Systems · doi:10.1109/37.642972 · Cited by 445
Cited by
The Hysteresis Bouc-Wen Model, a Survey
Ismail, M., Ikhouane, F., & Rodellar, J. (2009) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-009-9031-8 · Cited by 740
Computational methods in optimization considering uncertainties – An overview
Schuëller, G. I., & Jensen, H. A. (2008) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2008.05.004 · Cited by 572
Distributed Mass Damper System for Integrating Structural and Environmental Controls in Buildings
Fu, T. S., & Johnson, E. A. (2011) · Journal of Engineering Mechanics · doi:10.1061/(asce)em.1943-7889.0000211 · Cited by 53
Self-citationActive Control for a Distributed Mass Damper System
Fu, T. S., & Johnson, E. A. (2014) · Journal of Engineering Mechanics · doi:10.1061/(asce)em.1943-7889.0000650 · Cited by 16
Self-citationStructural Control Strategies for Earthquake Response Reduction of Buildings
(2014) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign) · Cited by 5
Metadata
- Authors
- Ramallo, J. C., Johnson, E. A., & Spencer, B. F.
- Venue
- Journal of Engineering Mechanics
- Published
- 2002-10
- Volume
- 128
- Issue
- 10
- Pages
- 1088-1099
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- DOI
- 10.1061/(asce)0733-9399(2002)128:10(1088
- OpenAlex
- W2045325874
- Cited by
- 376
- References
- 24
- FWCI
- 77.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: “Smart” Base Isolation Systems. https://app.cochat.ai/papers/10.1061/(asce)0733-9399(2002)128:10(1088
- The paper
- Ramallo, J. C., Johnson, E. A., & Spencer, B. F. (2002). “Smart” Base Isolation Systems. Journal of Engineering Mechanics. https://doi.org/10.1061/(asce)0733-9399(2002)128%3A10(1088
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.