Design of Circular Thin-Walled Concrete Filled Steel Tubes
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
In this paper several design methods have been developed that can be used to conservatively estimate the strength of circular thin-walled concrete filled steel tubes under different loading conditions. The loading conditions examined include axial loading of the steel only, axial loading of the concrete only, and simultaneous loading of the concrete and steel both axially and at small eccentricities. Recent tests on circular concrete filled steel tubes have been used to calibrate and validate the proposed design methods. The test specimens were short with a length-to-diameter ratio of 3.5 and a diameter thickness ratio between 60 and 220. The internal concrete had nominal unconfined cylinder strengths of 50, 80, and 120 MPa. The bond (or lack of) between the steel and internal concrete was critical in determining the formation of a local buckle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theoretical Stress‐Strain Model for Confined Concrete
Mander, J. B., Priestley, M. J. N., & Park, R. (1988) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1988)114:8(1804 · Cited by 8,454
Chung, K. F., & Narayanan, R. G. (1994) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 1,132
Building Code Requirements for Reinforced Concrete
ACI Committee (1962) · ACI Journal Proceedings · doi:10.14359/7919 · Cited by 610
Strength of Steel-Encased Concrete Beam Columns
Furlong, R. W. (1967) · Journal of the Structural Division · doi:10.1061/jsdeag.0001761 · Cited by 310
Strength of Concrete Filled Steel Tubular Columns
Knowles, R. B., & Park, R. (1969) · Journal of the Structural Division · doi:10.1061/jsdeag.0002425 · Cited by 273
Structural Behavior of Concrete Filled Steel Tubes
Gardner, N. J., & Jacobson, E. R. (1967) · ACI Journal Proceedings · doi:10.14359/7575 · Cited by 194
Beam-column behaviour of steel tubes filled with high strength concrete
Prion, H. G. L., & Boehme, J. (1994) · Canadian Journal of Civil Engineering · doi:10.1139/l94-024 · Cited by 164
Tests on Circular Thin-walled Steel Tubes Filled with Medium and High Strength Concrete
O’Shea, M. D., & Bridge, R. Q. (1998) · Cited by 49
Self-citationAxial Capacity of Concrete Infilled Cold-formed Steel Columns
Lin, C. Y. (1988) · Cited by 36
Use of Spiral Welded Steel Tubes in Pipe Columns
Gardner, N. J. (1968) · ACI Journal Proceedings · doi:10.14359/7525 · Cited by 31
Cited by
Axial capacity of circular concrete-filled tube columns
Giakoumelis, G., & Lam, D. (2004) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2003.10.001 · Cited by 638
State of the art report on steel–concrete composite columns
Shanmugam, N. E., & Lakshmi, B. (2001) · Journal of Constructional Steel Research · doi:10.1016/s0143-974x(01)00021-9 · Cited by 466
Structural design of stainless steel concrete filled columns
Lam, D., & Gardner, L. (2008) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2008.04.012 · Cited by 327
Sarir, P., Chen, J., Asteris, P. G., Armaghani, D. J., & Tahir, M. M. (2021) · Engineering with Computers · doi:10.1007/s00366-019-00808-y · Cited by 285
Experimental and computational study of concrete filled steel tubular columns under axial loads
Gupta, P. K., Sarda, S. M., & Kumar, M. S. (2007) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2006.04.004 · Cited by 234
Metadata
- Authors
- O'Shea, M. D., & Bridge, R. Q.
- Venue
- Journal of Structural Engineering
- Published
- 2000-11
- Volume
- 126
- Issue
- 11
- Pages
- 1295-1303
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2000)126:11(1295
- OpenAlex
- W2062597658
- Cited by
- 433
- References
- 10
- FWCI
- 21.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.