Nonlinear Analysis of Axially Loaded Concrete-Filled Tube Columns with Confinement Effect
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Proper material constitutive models for concrete-filled tube (CFT) columns are proposed and verified by the nonlinear finite element program ABAQUS against experimental data. The cross sections of the CFT columns in the numerical analysis are categorized into three groups, i.e., circular section, square section, and square section stiffened by reinforcing ties. Via the numerical analyses, it is shown that for circular CFT columns, the tubes can provide a good confining effect to the concrete especially when the width-to-thickness ratio D/t is small (say D/t<40). For square CFT columns, the tubes do not provide a large confining effect to the concrete especially when the width-to-thickness ratio B/t is large (say B/t>30). The confining effect of square CFT columns with reinforcing ties is enhanced by the use of reinforcing ties especially when the tie spacing is small and the tie number (or tie diameter) is large.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theoretical Stress‐Strain Model for Confined Concrete
Mander, J. B., Priestley, M. J. N., & Park, R. (1988) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1988)114:8(1804 · Cited by 8,454
318-14: Building Code Requirements for Structural Concrete and Commentary
(2014) · American Concrete Institute eBooks · doi:10.14359/51688187 · Cited by 1,408
A study of the failure of concrete under combined compressive stresses
Richart, F. E., Brandtzæg, A., & Brown, R. L. (1928) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign) · Cited by 949
Axially Loaded Concrete-Filled Steel Tubes
Schneider, S. P. (1998) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1998)124:10(1125 · Cited by 816
DISCUSSION OF EQUATION FOR THE STRESS - STRAIN CURVE OF CONCRETE’ BY DESAYI AND KRISHNAN
Sanez, L. P. (1964) · Cited by 554
Axial Load Behavior of Stiffened Concrete-Filled Steel Columns
Huang, C. S., Yeh, Y.-K., Liu, G.-Y., Hu, H.-T., Tsai, K. C., Weng, Y. T., Wang, S. H., & Wu, M.-H. (2002) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2002)128:9(1222 · Cited by 333
Self-citationStrength of Steel-Encased Concrete Beam Columns
Furlong, R. W. (1967) · Journal of the Structural Division · doi:10.1061/jsdeag.0001761 · Cited by 310
Strength of Concrete Filled Steel Tubular Columns
Knowles, R. B., & Park, R. (1969) · Journal of the Structural Division · doi:10.1061/jsdeag.0002425 · Cited by 273
Strength of Concrete‐Filled Thin‐Walled Steel Box Columns: Experiment
Ge, H., & Usami, T. (1992) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1992)118:11(3036 · Cited by 268
Local and post-local buckling of concrete filled steel welded box columns
Uy, B. (1998) · Journal of Constructional Steel Research · doi:10.1016/s0143-974x(98)80102-8 · Cited by 252
Cited by
Finite element modelling of concrete-filled steel stub columns under axial compression
Tao, Z., Wang, Z.-B., & Yu, Q. (2013) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2013.07.001 · Cited by 1,297
Behaviour of normal and high strength concrete-filled compact steel tube circular stub columns
Ellobody, E., Young, B., & Lam, D. (2006) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2005.11.002 · Cited by 464
Lee, S.-H., Uy, B., Kim, S.-H., Choi, Y.-H., & Choi, S.-M. (2011) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2010.07.003 · Cited by 191
Stiffened concrete-filled steel tubes: A systematic review
Alatshan, F., Osman, S. A., Hamid, R., & Mashiri, F. (2020) · Thin-Walled Structures · doi:10.1016/j.tws.2019.106590 · Cited by 129
Compressive strength of concrete-filled stainless steel tube stub columns
Dai, P., Yang, L., Wang, J., & Zhou, Y. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2019.110106 · Cited by 92
Chen, Z., Xu, W., & Zhou, J. (2022) · Engineering Structures · doi:10.1016/j.engstruct.2022.114993 · Cited by 59
Bond-slip behaviour of concrete filled double skin steel tubular (CFDST) columns
Hasan, H. G., & Ekmekyapar, T. (2021) · Marine Structures · doi:10.1016/j.marstruc.2021.103061 · Cited by 41
Metadata
- Authors
- Hu, H.-T., Huang, C.-S., Wu, M.-H., & Wu, Y.-M.
- Venue
- Journal of Structural Engineering
- Published
- 2003-10
- Volume
- 129
- Issue
- 10
- Pages
- 1322-1329
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2003)129:10(1322
- OpenAlex
- W2036049912
- Cited by
- 626
- References
- 13
- FWCI
- 20.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.