Seismic Behavior and Design of High-Strength Square Concrete-Filled Steel Tube Beam Columns
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The behavior of high strength square concrete filled steel tube (CFT) beam columns subjected to constant axial load and cyclically varying flexural loading was investigated experimentally. The effects of the width-to-thickness (b/t) ratio, the yield stress (σy) of the steel tube, and the level of axial load on the behavior (stiffness, strength, ductility, and energy dissipation) of high strength square CFT beam columns were studied. Eight cyclic beam-column specimens were tested. Crushing of concrete and cyclic local buckling in the steel tube affected the cyclic strength and stiffness of the CFT specimens. The elastic section flexural stiffness under cyclic loading decreases rapidly due to tension cracking of the concrete infill and local buckling of the steel tube. The total energy dissipated by the cyclic specimens is dominated by the flexural energy dissipated in the failure segment (plastic hinge region). Both the current American Concrete Institute code provisions and the modified Architectural Institute of Japan method predict the moment capacities of the high strength square CFT specimens accurately. The cyclic curvature ductility (μϕ-c) decreases significantly with an increase in the axial load level. At higher axial load levels, the steel tube b/t ratio and σy have a small influence on μϕ-c. However, at lower axial load levels, increasing the steel tube b/t ratio or σy reduces μϕ-c.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American society for testing and materials
Mather, B., & Etris, S. F. (2006) · Encyclopedia of Earth Science · doi:10.1007/0-387-30720-6_5 · Cited by 5,558
Design of composite steel and concrete structures
Johnson, R. P., & Anderson, D. R. (1993) · Thomas Telford eBooks · Cited by 378
Architectural Institute of Japan
(1999) · TRENDS IN THE SCIENCES · doi:10.5363/tits.4.5_37 · Cited by 275
Experimental Behavior of High Strength Square Concrete-Filled Steel Tube Beam-Columns
Varma, A. H., Ricles, J. M., Sause, R., & Lu, L.-W. (2002) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2002)128:3(309 · Cited by 203
Self-citation
Cited by
Structural behavior of UHPC filled steel tube columns under axial loading
Chen, S., Zhang, R., Jia, L.-J., Wang, J.-Y., & Gu, P. (2018) · Thin-Walled Structures · doi:10.1016/j.tws.2018.06.016 · Cited by 181
“This is unfavorable to the load transfer between the steel tube and the core concrete, which weakens the composite effect of the cross section, resulting in a sharp drop in axial load after the peak strength [15,16].”
BackgroundUltra-High Strength Concrete Filled Composite Columns for Multi-Storey Building Construction
Liew, J. Y. R., & Xiong, D. X. (2012) · Advances in Structural Engineering · doi:10.1260/1369-4332.15.9.1487 · Cited by 170
Structural behavior of UHPC filled steel tubular columns under eccentric loading
Zhang, R., Chen, S., Gu, P., & Huang, Y. (2020) · Thin-Walled Structures · doi:10.1016/j.tws.2020.106959 · Cited by 88
Metadata
- Authors
- Varma, A. H., Ricles, J. M., Sause, R., & Lu, L.-W.
- Venue
- Journal of Structural Engineering
- Published
- 2004-02
- Volume
- 130
- Issue
- 2
- Pages
- 169-179
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2004)130:2(169
- OpenAlex
- W1986046962
- Cited by
- 177
- References
- 4
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.