Large-Scale Experimental Verification of Semiactive Control through Real-Time Hybrid Simulation
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Magneto-rheological (MR) fluid dampers have been identified as a particularly promising type of semiactive control device for hazard mitigation in civil engineering structures. Large-scale experimental testing is important to verify the performance of MR fluid dampers for seismic protection of civil structures. Real-time hybrid testing, where only the critical components of the system are physically tested while the rest of the structure is simulated, can provide a cost-effective means for large-scale testing of semiactive controlled structures. This paper describes the real-time hybrid simulation experimental setup for multiple large-scale MR fluid dampers and demonstrates the capability at the University of Colorado at Boulder shared-use Fast Hybrid Test facility to conduct real-time hybrid testing within the Network for Earthquake Engineering Simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phenomenological Model for Magnetorheological Dampers
Spencer, B. F., Dyke, S. J., Sain, M. K., & Carlson, J. D. (1997) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1997)123:3(230 · Cited by 2,055
A controller to overcome dead time
Smith, O. J. M. (1959) · Medical Entomology and Zoology · Cited by 1,279
Supplemental energy dissipation: state-of-the-art and state-of-the-practice
Soong, T. T., & Spencer, B. F. (2002) · Engineering Structures · doi:10.1016/s0141-0296(01)00092-x · Cited by 1,220
A constraint-based god-object method for haptic display
Zilles, C. B., & Salisbury, J. K. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525876 · Cited by 819
The haptic display of complex graphical environments
Ruspini, D. C., Kolarov, K., & Khatib, O. (1997) · Proceedings of the 24th annual conference on Computer graphics and interactive techniques - SIGGRAPH '97 · doi:10.1145/258734.258878 · Cited by 589
Robust control of dynamically interacting systems
COLGATE, J. E., & HOGAN, N. (1988) · International Journal of Control · doi:10.1080/00207178808906161 · Cited by 589
An experimental study of MR dampers for seismic protection
Dyke, S. J., Spencer, B. F., Sain, M. K., & Carlson, J. D. (1998) · Smart Materials and Structures · doi:10.1088/0964-1726/7/5/012 · Cited by 540
Controlling buildings: a new frontier in feedback
(1997) · IEEE Control Systems · doi:10.1109/37.642972 · Cited by 445
Issues in the haptic display of tool use
Colgate, J. E., Stanley, M. C., & Brown, J. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525875 · Cited by 404
Role of Control-Structure Interaction in Protective System Design
Dyke, S. J., Spencer, B. F., Quast, P., & Sain, M. K. (1995) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1995)121:2(322 · Cited by 329
Cited by
Smart structures: Part I—Active and semi-active control
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.034 · Cited by 270
Zhang, Z., Staino, A., Basu, B., & Nielsen, S. R. K. (2016) · Engineering Structures · doi:10.1016/j.engstruct.2016.07.008 · Cited by 150
Metadata
- Authors
- Christenson, R., Lin, Y. Z., Emmons, A., & Bass, B.
- Venue
- Journal of Structural Engineering
- Published
- 2008-04
- Volume
- 134
- Issue
- 4
- Pages
- 522-534
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2008)134:4(522
- OpenAlex
- W2120986736
- Cited by
- 168
- References
- 22
- FWCI
- 23.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.