CoChat

LID Treatment Train: Pervious Concrete with Subsurface Storage in Series with Bioretention and Care with Seasonal High Water Tables

Brown, R. A., Line, D. E., Hunt, W. F. · 2012 · Journal of Environmental Engineering
Cited by 57

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Two infiltrating low-impact development (LID) practices configured in-series, pervious concrete and bioretention (PC-B), were monitored for 17 months to examine the hydrologic and water quality response of this LID treatment train design. For the first LID practice, 0.53 ha of pervious concrete was installed to treat direct rainfall and run-on from 0.36 ha of asphalt parking lot. The pervious concrete was installed over a gravel subsurface storage basin, which was designed to store 25 mm (1 in.) of runoff from the parking lot before draining into the second LID practice, which was a 0.05 ha bioretention cell. The bioretention cell was conventionally drained, had a media depth of 0.5 m (1.6 ft), and was constructed at a location with a high water table. Outflow was only generated in 33 out of 80 monitored events, and over the course of the entire monitoring period, the total outflow volume reduction was 69%. The large outflow reduction subsequently led to high pollutant load reductions for total nitrogen (49%), total phosphorus (51%), and total suspended solids (89%). However, when the contribution of base flow was included in the calculation, the total nitrogen load discharged from the bioretention cell was 64% higher than that of the runoff load because of nitrite and nitrate, NO2- and NO3-(NO2,3-N), which were present in the base flow. The total nitrogen (TN) loads of runoff, storm flow (total outflow minus base flow), base flow, and outflow (total) were 7.70, 3.94, 8.69, and 12.64 kg/ha·year, respectively. Of the 8.69 kg/ha·year TN in the base flow, 92% was in the form of NO2,3-N. This study demonstrated the hydrologic benefits (peak flow and outflow reduction) gained by having two infiltration LID practices in-series. When compared with a single treatment practice (bioretention) that was monitored at the same site, the two LID practices in-series treated an additional 10% of annual runoff volume, discharged approximately one-half as much outflow volume, and discharged significantly lower peak outflow rates. However, the water quality results were not as promising because of the influx of groundwater in the bioretention cell and the lack of denitrifying conditions in either the bioretention cell or pervious concrete system. This study also quantified increased TN and NO2,3-N export to surface waters from a bioretention cell that was situated in an area with a high water table.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1061/(asce)ee.1943-7870.0000506

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
Brown, R. A., Line, D. E., & Hunt, W. F.
Venue
Journal of Environmental Engineering
Published
2012-06
Volume
138
Issue
6
Pages
689-697
ISSN
  • 0733-9372 (ISSN-L)
  • 1943-7870
OpenAlex
W2123694151
Cited by
57
References
1
FWCI
1.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.