The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fast Bayesian FFT Method for Ambient Modal Identification with Separated Modes
Abstract
Previously a Bayesian theory for modal identification using the fast Fourier transform (FFT) of ambient data was formulated. That method provides a rigorous way for obtaining modal properties as well as their uncertainties by operating in the frequency domain. This allows a natural partition of information according to frequencies so that well-separated modes can be identified independently. Determining the posterior most probable modal parameters and their covariance matrix, however, requires solving a numerical optimization problem. The dimension of this problem grows with the number of measured channels; and its objective function involves the inverse of an ill-conditioned matrix, which makes the approach impractical for realistic applications. This paper analyzes the mathematical structure of the problem and develops efficient methods for computations, focusing on well-separated modes. A method is developed that allows fast computation of the posterior most probable values and covariance matrix. The analysis reveals a scientific definition of signal-to-noise ratio that governs the behavior of the solution in a characteristic manner. Asymptotic behavior of the modal identification problem is investigated for high signal-to-noise ratios. The proposed method is applied to modal identification of two field buildings. Using the proposed algorithm, Bayesian modal identification can now be performed in a few seconds even for a moderate to large number of measurement channels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, R. (2001) · doi:10.56021/9780801869822 · Cited by 462
Uncertainty bounds on modal parameters obtained from stochastic subspace identification
Reynders, E., Pintelon, R., & De Roeck, G. (2008) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2007.10.009 · Cited by 454
Cited by
Vibration-based monitoring of civil infrastructure: challenges and successes
Brownjohn, J. M. W., De Stefano, A., Xu, Y.-L., Wenzel, H., & Aktan, A. E. (2011) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-011-0009-5 · Cited by 336
Wu, R.-T., & Jahanshahi, M. R. (2020) · Structural Health Monitoring · doi:10.1177/1475921718798769 · Cited by 257
HIERARCHICAL SPARSE BAYESIAN LEARNING FOR STRUCUTRAL HEALTH MONITORING WITH INCOMPLETE MODAL DATA
Huang, Y., & Beck, J. L. (2015) · International Journal for Uncertainty Quantification · doi:10.1615/int.j.uncertaintyquantification.2015011808 · Cited by 87
Spectral characteristics of asynchronous data in operational modal analysis
Zhu, Y.-C., & Au, S.-K. (2017) · Structural Control and Health Monitoring · doi:10.1002/stc.1981 · Cited by 18
“Next, modal properties are estimated from the synchronous data set using Bayesian FFT method [39].”
MethodInfluential
Metadata
- Authors
- Au, S.-K.
- Venue
- Journal of Engineering Mechanics
- Published
- 2011-03
- Volume
- 137
- Issue
- 3
- Pages
- 214-226
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- OpenAlex
- W2106093286
- Cited by
- 243
- References
- 2
- FWCI
- 24.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast Bayesian FFT Method for Ambient Modal Identification with Separated Modes. https://app.cochat.ai/papers/10.1061/(asce)em.1943-7889.0000213
- The paper
- Au, S.-K. (2011). Fast Bayesian FFT Method for Ambient Modal Identification with Separated Modes. Journal of Engineering Mechanics. https://doi.org/10.1061/(asce)em.1943-7889.0000213
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.