Performance and Cost Evaluation of a Smart Tuned Mass Damper for Suppressing Wind-Induced Lateral-Torsional Motion of Tall Structures
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The implementation of a vibration control system has always been associated with considerable capital and long-standing maintenance costs, resulting in limited practical applications of damping devices. The notion of a massive implementation cost is largely the result of a lack of cost analysis of vibration control systems in the literature. This paper presents the structural design of a wind-sensitive tall building at various design stages and the results of a collaborative study with two damper construction companies on the cost estimation of a control device. A series of wind tunnel pressure tests were conducted on a 1∶400 scale model to determine the translational and torsional wind forces acting on the studied building. A structural optimization was subsequently employed to reduce the excessive top deflection, and a smart tuned mass damper was implemented at the final design stage to meet occupant comfort criteria. The details of each structural design stage, the implementation of vibration control devices, and a collaborative study on damper cost are outlined in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semi-active control systems for seismic protection of structures: a state-of-the-art review
Symans, M. D., & Constantinou, M. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00225-3 · Cited by 706
Performance of tuned mass dampers under wind loads
Kwok, K. C. S., & Samali, B. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00035-6 · Cited by 206
Self-citation
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
Giaralis, A., & Petrini, F. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001863 · Cited by 330
Wang, J., Wierschem, N. E., Wang, B., & Spencer, B. F. (2020) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1692 · Cited by 62
Tuned mass damper inerter for seismic control of multi-story buildings: Ten years since inception
Konar, T., & Ghosh, A. (. (2024) · Structures · doi:10.1016/j.istruc.2024.106459 · Cited by 57
Calayir, M., Tao, J., Mercan, O., & Bezabeh, M. A. (2026) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.70129 · Cited by 8
Metadata
- Authors
- Tse, K. T., Kwok, K. C. S., & Tamura, Y.
- Venue
- Journal of Structural Engineering
- Published
- 2012-04
- Volume
- 138
- Issue
- 4
- Pages
- 514-525
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- OpenAlex
- W2131202434
- Cited by
- 61
- References
- 2
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance and Cost Evaluation of a Smart Tuned Mass Damper for Suppressing Wind-Induced Lateral-Torsional Motion of Tall Structures. https://app.cochat.ai/papers/10.1061/(asce)st.1943-541x.0000486
- The paper
- Tse, K. T., Kwok, K. C. S., & Tamura, Y. (2012). Performance and Cost Evaluation of a Smart Tuned Mass Damper for Suppressing Wind-Induced Lateral-Torsional Motion of Tall Structures. Journal of Structural Engineering. https://doi.org/10.1061/(asce)st.1943-541x.0000486
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.